Empowering Scientific Discovery

Beijing East & West Analytical Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable Gas Chromatograph
Application FieldCoal Mining Industry
Detection Channels3 Independent Parallel Channels (A/B/C)
Channel AO₂, N₂, CH₄, CO₂
Channel BC₂H₄, C₂H₆, C₂H₂, C₃H₈, H₂S
Channel CH₂, CO
LODO₂/N₂/CH₄/CO₂ ≤ 0.1% (v/v)
Quantitative Repeatability≤ 3% RSD
Sample IntroductionMotorized 10-Port Automatic Valve with Precise Retention Time Control
Control InterfaceIndustrial Touchscreen LCD with One-Touch Power-On Sequence
Data OutputReal-Time Peak Area and Concentration Calculation per Component
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analytical
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Regional ClassificationDomestic (China)
ModelGC-4100
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range(Ambient + 5) °C to 400 °C
Oven Ramp Rate0.1–40 °C/min
Oven Cool-Down Rate400 °C → 50 °C (typical)
Carrier Gas Flow Control Range1–500 mL/min (EPC)
Carrier Gas Pressure Control Range0–145 psi (EPC)
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–145 psi (EPC)
Injector Total Flow Setting Range1–500 mL/min (EPC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (PRC)
ModelLC-5510
Instrument CategoryConventional HPLC System
Flow Rate Range0.001–10.000 mL/min
Maximum Operating Pressure42 MPa
Autosampler Capacity120 positions
Injection Volume Range0.1–100 µL
Column Oven Temperature Range5–80 °C
UV-Vis Detector Wavelength Range190–700 nm
Data Acquisition FrequencyUp to 100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelGC-4008B
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application DomainCoal Mining Safety & Spontaneous Combustion Monitoring
Detection SystemsTCD, Dual FID, ECD, FPD
Column ConfigurationFour Dedicated Capillary/Packed Columns
Temperature Program10-Stage Programmable Ramp
Carrier GasesHelium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD)
Minimum Detectable ConcentrationsCO, C₂H₂ ≤ 0.5 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analytical Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeConventional HPLC System
Flow Rate Range0–50 mL/min
Maximum Operating Pressure42 MPa
Flow Accuracy≤0.5% RSD
Sample Injection Volume0.1–100 µL
Injection Capacity120 positions (1.8 mL vials)
Column Oven Temperature Range5–80 °C
UV-Vis Wavelength Range190–700 nm
Pressure Pulsation (without damper)<0.4%
Pressure Pulsation (with damper)<0.015%
Detection PrincipleUV-Vis absorbance with differential refractive index suppression and 40-mm optical path length flow cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
ModelIC-2800
Instrument TypeBenchtop Laboratory System
Pump Maximum Pressure35 MPa
Flow Rate Range0.01–10.00 mL/min
Eluent Flow Rate Accuracy±0.1% RSD
Maximum Operating Pressure35 MPa
Eluent Concentration Range1–100 mM (KOH, MSA, Na₂CO₃/NaHCO₃, etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelGC-4000A
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Analytical GC
Oven Temperature Range(Ambient + 5)°C to 400°C
Programmable Temperature RampUp to 40°C/min (typical range)
Carrier Gas Flow Control Range0–100 mL/min (N₂, H₂, He)
Carrier Gas Pressure Control Range0–100 psi
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–120 mL/min
Detector OptionsTCD, FID, FPD, NPD, ECD (user-selectable, up to three simultaneously)
Column CompatibilityPacked columns and capillary columns (0.1–0.53 mm ID)
Temperature Zones7 independently controlled zones (oven, injector ×1, detectors ×3, auxiliary ×2)
Oven Programmability10-step temperature program with ramp hold
CoolingMotorized rear door auto-opening for accelerated oven cooldown
Gas SystemConfigurable single/dual/triple gas channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient +5 °C to 460 °C
Injector Maximum Operating Temperature450 °C
Operating SystemLinux-based Embedded OS
Communication InterfaceEthernet (RJ-45)
Display10-inch Capacitive Touchscreen
Auto-sampler CompatibilityDual-tower liquid auto-sampler mounting platform
Oven DesignDual rear-opening column oven with rapid thermal response architecture
Pneumatic ControlFully Electronic Pressure Control (EPC) for all gas channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Mining Industry (Mine Fire Early Warning & Gas Hazard Monitoring)
Touchscreen10.1-inch Industrial-Grade Capacitive LCD
Operating SystemLinux-based Real-Time Embedded OS
Column Oven CoolingRear-Door Rapid-Cooling System with Dedicated Airflow Channel
Carrier Gas ControlElectronic Pressure Control (EPC) with Mass Flow Sensors
DiagnosticsOnboard Self-Diagnostic Engine with Fault Code Logging
Remote AccessWeb-Based Interface + Native Android/iOS Mobile App
Sampling ModeFully Automated Sequential Analysis from 1 to 32 Sampling Points
Dual Independent Column OvensSeparate Temperature Zones for High-Temp and Low-Temp Columns
Backflush CapabilityProgrammable Carrier Gas Reverse Flow for Column Protection
Analysis Time≤10 min per injection for 12 Key Gases (CO, CO₂, N₂, O₂, CH₄, C₂H₄, C₂H₆, C₂H₂, C₃H₈, C₃H₆, iC₄H₁₀, nC₄H₁₀)
Data OutputAutomatic Report Generation & Secure Cloud Upload via Ethernet/Wi-Fi
Sample Inlet OptionsFlexible Integration with Bundled Tube Systems, Tedlar® Bags, or Polyethylene Sampling Bags
ComplianceDesigned to Support ASTM D1945, ISO 8573-5, and GB/T 13610–2020 for Mine Gas Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Industry-Specific Analysis
Key Features13-component fire-gas analysis in 10–15 min per injection
Display10-inch capacitive touchscreen interface
Safety SystemsOvertemperature protection, low-temperature alarm, open-circuit detection, carrier-gas failure shutdown
Flow ControlHigh-precision electronic pressure/flow controllers (EPC/EFC) with real-time digital flow readout for all pneumatic channels
Remote OperationMobile app support (iOS/Android) for instrument monitoring and control
Column Oven SafetyAutomatic motor stop and heater cutoff upon oven door opening
Data IntegrationCustomizable data upload via configurable communication protocols (e.g., Modbus TCP, OPC UA, or customer-defined API)
Automation LevelFully computer-controlled operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGBC
OriginAustralia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLC 3000
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0