Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeManufacturer
Instrument TypeTime-of-Flight Mass Spectrometer
Chromatography ConfigurationComprehensive Two-Dimensional Gas Chromatography (GC×GC)
ModelGCxGC TOF MS 3300
Mass RangeNot specified
ResolutionNot specified
SensitivityNot specified
Scan Speed500 spectra/sec (≥15 kHz pusher frequency)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC-MS3110
Instrument TypeSingle Quadrupole Mass Spectrometer
GC/MS ConfigurationConventional Benchtop GC-MS
Mass Range1.5–800 Da
Resolution2 M (10% valley definition)
Sensitivity30:1 (S/N for 1 pg octafluoronaphthalene, m/z 272, in full-scan mode)
Scan Speed6000 u/sec
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEast & West Analysis
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ConfigurationConventional Capillary GC-MS
Mass Range1.5–1100 amu
Mass ResolutionUnit Mass Resolution
Sensitivity≥2000:1 S/N for 1 pg Octafluoronaphthalene (OFN) in Electron Ionization (EI) mode
Scan SpeedUp to 10,000 amu/s
DetectorDual-Stage Electron Multiplier with High-Energy Dynode Post-Focusing Assembly
Pressure Control Accuracy±0.001 psi
Column OvenAir-heated, accommodates up to two capillary columns and three detector modules
Ion SourceHigh-Temperature Inert EI Source with dual long-life inert filaments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analytical
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSingle Quadrupole GC-MS
GC ConfigurationConventional Capillary GC-MS
Mass Range1–1000 amu
Mass ResolutionUnit Mass Resolution (UMR)
Sensitivity100:1 (Signal-to-Noise Ratio, S/N, for m/z 69 of perfluorotributylamine, PFTBA, at 1 pg on-column)
Scan SpeedUp to 10,000 amu/s
Ion SourceDual-Mode Electron Ionization (EI) and Programmable Positive Chemical Ionization (PCI)
Ion OpticsDC Compensation Voltage Tuning
Filament ControlAdaptive Emission Current & Electron Energy Regulation
GC Oven Temperature Stability±0.01 °C
Pressure/Flow ControlThird-Generation Electronic Pneumatic Control (EPC) Module
Optional AccessoryIn-House Designed Low-Noise Mechanical Pump Enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxi Analysis
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ConfigurationConventional Capillary Gas Chromatograph
Mass RangeNot Specified (Typical for Single Quadrupole: 10–1000 u)
ResolutionUnit Mass Resolution
SensitivityNot Specified (Typical: <10 fg OFN in Full Scan, S/N ≥ 50:1)
Scan SpeedNot Specified (Typical: Up to 10,000 Da/sec)
Carrier Gas ControlElectronic Pressure Control (EPC)
Vacuum SystemConfigurable Dual-Stage Pumping (Turbo + Roughing Pump Options)
Library CompatibilityNIST, Wiley, and Custom User Libraries
Interface OptionsPurge & Trap, Thermal Desorption Unit (TDU), Headspace Sampler, Direct Insertion Probe (DIP)