Add to compare
BrandRikari Chemical
OriginJapan
ModelAquaTester 10
Instrument TypePortable
Measurement PrincipleVisual Colorimetric Comparison (DPD & BTB Methods)
Measured ParametersFree Chlorine, Total Chlorine, Residual Chlorine, pH, Total Hardness (as CaCO₃)
RangeFree Chlorine: 0.05–2.0 mg/L (low-range DPD)
Total/Residual Chlorine10–200 mg/L (high-range HOCl-K)
pH5.8–8.6
Total Hardness5–300 mg/L as CaCO₃
Accuracy±2% of reading
Repeatability±3% RSD
Resolution1 ppm (for chlorine parameters)
LOD1 ppm
Included Reagents50× DPD-F-1 (free chlorine), 50× DP-TL-1 (total chlorine), 50× RC-7Z (active chlorine), 18 mL BTB-7Z (pH indicator), 18 mL BTS liquid reagent (pH), and TH-7Z hardness reagents
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRikari
OriginJapan
ModelRC-3F
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measured ParameterFree Chlorine (as Cl₂)
Range0–500 mg/L
Accuracy±2% of reading
Repeatability±2% RSD
Resolution1 mg/L
LOD1 mg/L
Power4 × AAA alkaline batteries (DC 6 V)
Operating Temperature5–35 °C
Dimensions75 × 180 × 38 mm (W × D × H)
Sample Volume5 mL
ReagentHOCl-K-1 powder packet (single-use, pre-dosed)
Display3-digit LCD
Auto-off5 seconds after measurement
Hold functionYes
Over-range alertFlashing display above 550 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRikori
OriginJapan
ModelH2O2-V7
Instrument TypePortable
Measurement PrincipleUV Absorption Photometry (254 nm LED source)
Measurement ParameterHydrogen Peroxide (H₂O₂)
Range0–4000 mg/L (ppm)
Accuracy±2% of full scale
Repeatability±2% of full scale
Resolution1 mg/L
Detection Limit0.5 mg/L
Response Time≤10 s
Operating Temperature1–35 °C
Power SupplyDC 6 V
Dimensions88 × 174 × 65 mm
Weight310 g
ComplianceDesigned for industrial process monitoring per ISO 7027 principles (UV absorbance-based quantification), compatible with GLP-aligned data recording workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKasahara
OriginJapan
ModelRC-V2
Instrument TypePortable
Measurement PrincipleDPD Spectrophotometry
Measured ParametersChlorine Dioxide (ClO₂) and Total/Free Available Chlorine
Measurement Range0–200 g/L (multi-range, auto-ranging)
Accuracy±5% of reading
Repeatability≤2% RSD
Detection Limit0.01 mg/L (at lowest range)
WavelengthsTriple-wavelength optical system (515 nm, 550 nm, 610 nm)
ComplianceDesigned for HACCP-aligned disinfection process control
Power SupplyRechargeable Li-ion battery (≥8 hrs continuous operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRikari
OriginJapan
ModelRC-V7
Instrument TypePortable
Measurement PrincipleUV-LED Absorption Photometry (Deep UV, 254 nm)
Measured ParameterResidual Chlorine (as Cl₂), Chlorine Dioxide (ClO₂)
Range Mode 10–1000 mg/L
Range Mode 20–500 mg/L
Accuracy±1% of reading
Repeatability±2% (under controlled conditions)
Resolution1 mg/L
LOD1 mg/L
Operating Temperature1–35 °C
Power Supply4 × AA alkaline batteries (DC 6 V)
Weight~310 g