Empowering Scientific Discovery

Beijing Huakeyi Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-328
Display192 × 64 dot-matrix LCD (Chinese/English selectable)
pH Range0.00–14.00 pH
ORP Range−1000 to +1000 mV
Temperature Range0.00–99.9 °C
ATC Range0.1–60.0 °C
pH Resolution0.01 pH
mV Resolution0.1 mV
Temp. Resolution0.1 °C
pH Accuracy±0.05 pH
Temp. Accuracy±0.5 °C
Response Time (T90)90 s at 25 °C
OutputDual isolated 4–20 mA (or 0–10 mA / 0–20 mA), configurable for pH or temperature
Max. Load800 Ω @ 20 mA
Alarm Outputs2 programmable relay outputs
CommunicationRS-485, Profibus DP, HART
Sample Temp.5–50 °C
Sample Flow Rate6 L/h
Max. Suspended Solids≤5 µm (no colloids or oils)
Ambient Temp.5–45 °C
Humidity≤90% RH (non-condensing)
Storage Temp.−20 to +55 °C (electrode stored separately >0 °C)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
Dimensions146 × 146 × 154 mm (W×H×D)
Panel Cutout139 × 139 mm
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-1309pH
Measurement PrincipleConductivity-based pH calculation (VGB-R 450L compliant)
pH Range7.5–11.5
Cation Conductivity Range0.000–200.0 µS/cm (with selectable cell constants: 0.01, 0.1, 1.0 cm⁻¹)
Resolution0.001–0.1 µS/cm (dependent on range)
Ammonia Range0.01–10 ppm
Temperature CompensationLinear, neutral salt, ammonia water, strong acid modes
ComplianceHK-338 Enterprise Standard, JJG 376–2007 Verification Regulation for Conductivity Meters
System IntegrationIntegrated stainless-steel panel with flow cell, cation exchange column, regeneration unit, solenoid valves, and dual-conductivity sensors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
ModelHK-6010
Measurement RangepH 2.00–11.00
Temperature Range0.00–99.9 °C
ATC Range0.1–60 °C
pH Resolution0.01 pH
Temperature Resolution0.1 °C
pH Accuracy±0.1 pH
Temperature Accuracy±0.5 °C
Output SignalsIsolated 0–10 mA / 0–20 mA / 4–20 mA (±1% FS)
Sample Temp.5.0–50.0 °C
Max. Sample Pressure<0.6 MPa
Ambient Temp.5–50 °C
Humidity≤95% RH
Dimensions (Enclosure)300 mm × 400 mm × 200 mm (W×H×D)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤40 W
Dielectric Strength1500 VAC for 1 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
ModelHK-328W
EnclosureDie-cast aluminum, ESD-safe
Display192 × 64 dot-matrix LCD (Chinese/English selectable)
pH Range0.00–14.00 pH
mV Range−1000 to +1000 mV
Temperature Range0.00–99.9 °C (ATC: 0.1–60.0 °C)
pH Resolution0.01 pH
mV Resolution0.1 mV
Temp. Resolution0.1 °C
pH Accuracy±0.1 pH
Temp. Accuracy±0.5 °C
OutputDual isolated 4–20 mA (or 0–10 mA / 0–20 mA), ±1% FS, load ≤800 Ω
Alarm Outputs2 relay outputs
CommunicationRS485, Profibus DP, HART
Sample Temp.0.0–60.0 °C
Max. Sample Pressure<0.6 MPa
Ambient Temp.5–60 °C
Humidity≤95% RH
Storage Temp.−25–55 °C (electrode storage >0 °C)
PowerAC 100–240 V, 50–60 Hz
Power Consumption8 W
Dimensions158 × 158 × 170 mm (W×H×D)
Panel Cutout139 × 139 mm
Weight2 kg
Electrode TypeWastewater-compatible triple-junction composite pH electrode (standard 10 m or optional 20 m cable)