Empowering Scientific Discovery

Beijing Huakeyi Science & Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-218 (New Generation)
TypeBenchtop Laboratory Analyzer
Measurement Range0–200 μg/L or 0–2000 μg/L
Resolution0.1 μg/L
Accuracy±2% FS
Repeatability≤1%
Stability±1% FS / 4 h
Display192 × 64 dot-matrix LCD (Chinese/English switchable)
Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions392 × 260 × 100 mm (L × W × H)
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
ModelHK-358AO
TypeOnline Sodium Ion Monitor
Measurement Range(1.00–8.00) pNa, 0.23 μg/L–2.30 g/L, (0.00–14.00) pH
Detection Limit0.01 pNa, 0.01 μg/L, 0.01 pH
Response Time≤2 min at 25 °C
Temperature Range(0.0–99.9) °C
Temperature Accuracy±0.5 °C
Resolution0.01 pNa / 0.01 μg/L / 0.01 pH
Channels1–4 configurable
OutputFour isolated (0–10) mA / (0–20) mA / (4–20) mA current outputs
CommunicationRS-485 or Profibus-DP optional
Dimensions451 mm × 684 mm × 230 mm (W×H×D)
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-358 Steam
TypeOnline Sodium Ion Analyzer
Measurement Range(1.00–8.00) pNa, 0.23 µg/L – 2300 mg/L
Detection Limit0.01 pNa or 0.01 µg/L
Response Time (T90)2 min at 25 °C
Accuracy±0.05 pNa or ±5 µg/L (whichever is greater, within ±10 °C of calibration temperature)
Temperature Range(0.00–99.9) °C
Temperature CompensationAutomatic or Manual (0.1–60.0 °C)
OutputDual isolated 4–20 mA (or 0–10/0–20 mA), dual programmable alarm relays
Display192 × 64 dot-matrix LCD (English/Chinese selectable)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
Dimensions450 mm × 690 mm × 190 mm (W × H × D)
Weight20 kg
EnclosureAluminum chassis, panel-mount design
ComplianceDesigned for continuous steam-phase sodium monitoring in high-purity water/steam cycles per IAPWS guidelines and power plant QA/QC protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-51
Instrument CategorySodium Ion Analyzer
Form FactorBenchtop
Measurement Range(1.00–8.00) pNa, 0.23 μg/L – 2.30 g/L
Detection Limit0.01 pNa, 0.01 μg/L
Response Time (T90)2 min at 25 °C
Accuracy±0.03 pNa or ±5 μg/L (whichever is greater)
Temperature Range(0.00–99.9) °C
Display192 × 64 dot-matrix LCD (English/Chinese selectable)
Resolution0.01 pNa, 0.01 μg/L
Input Impedance≥1 × 10¹² Ω
Temperature SensorPt1000
Temp. CompensationAutomatic or Manual (0.1–60.0 °C)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption3 W
Dimensions270 × 200 × 65 mm (L × W × H)
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelHK-108W
Price RangeUSD 14,000 – 42,000 (FOB)
Instrument TypeOnline Continuous Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-288
Price RangeUSD 4,200 – 7,000 (FOB)
Instrument TypeLaboratory Turbidimeter
Measured ParameterTurbidity
Operating SystemWindows CE
Display7-inch TFT LCD Touchscreen
Light SourceHigh-Stability Infrared LED (850 nm)
Measurement PrincipleNephelometric Detection (90° Scattered Light) with Chromatic Compensation
Range0–1000 NTU
Resolution0.01 NTU
Accuracy±5% of reading
Repeatability±1% RSD
Drift≤±1.5% FS / 30 min
UnitsNTU, FTU, mg/L (as SiO₂)
Data Storage100,000 records (measurements, calibrations, system logs)
InterfaceUSB 2.0
Calibration Options1-, 2-, or multi-point (up to 5 points)
ComplianceCMC Certified (China Metrology Certification, Certificate No. CMCC2023-XXXXX)
Environmental Operating Conditions5–45 °C ambient
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption10 W
Dimensions (L×W×H)390 × 248 × 175 mm
Weight4.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-518
Price RangeUSD 1,400 – 4,200 (FOB)
Instrument TypeBenchtop Water Quality Analyzer
AnalyteCu²⁺ (Copper Ions)
Display192 × 64 Dot-Matrix LCD (Chinese/English Switchable)
Measurement Range0–200 µg/L
Resolution0.1 µg/L
Accuracy±2% FS
Repeatability≤1% RSD
Stability±2% FS / 4 h
Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions (L×W×H)392 × 260 × 100 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-508
Price RangeUSD 1,400 – 4,200 (FOB)
Instrument TypeBenchtop Laboratory Water Quality Analyzer
AnalyteTotal Dissolved Iron (Fe²⁺/Fe³⁺)
Display192 × 64 Dot-Matrix LCD (Chinese/English Switchable)
Measurement Range0–200 µg/L
Resolution0.1 µg/L
Accuracy±3% FS
Repeatability≤1.5% RSD
Drift≤±1.5% FS / 4 h
Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions (L×W×H)392 × 260 × 100 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelHK-51
Price RangeUSD 700–1,400 (FOB)
Instrument TypeSodium Ion-Specific Analyzer
Form FactorBenchtop
Measurement Range(1.00–8.00) pNa, equivalent to 0.23 µg/L–2.30 g/L Na⁺
Detection Limit±0.03 pNa or ±5 µg/L (whichever is greater)
Response Time (T₉₀)2 min at 25 °C
Temperature CompensationAutomatic or Manual (0.1–60.0 °C)
Temperature Measurement Range(0.0–99.9) °C
Temperature Accuracy±0.5 °C
Display192×64 dot-matrix LCD (English/Chinese selectable)
Resolution0.01 pNa / 0.01 µg/L
Electronic Unit Error±0.01 pNa or ±1 digit
Stability±0.01 pNa / 4 h
Input Impedance≥1×10¹² Ω
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption3 W
Dimensions270 × 200 × 65 mm (L×W×H)
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
ModelHK-258
Instrument TypePortable
Measurement PrinciplePolarographic Electrochemical Sensor
Measurement Range0.00–200 µg/L
Accuracy±0.3% FS or 1 µg/L (whichever is greater)
Repeatability0.05%
Detection Limit0.1 µg/L
Resolution0.1 µg/L, 0.01 mg/L
Temperature Compensation Range0–50 °C (manual or automatic)
Temperature Accuracy±0.5 °C
Temperature Resolution0.1 °C
Response Time (T90)≤60 s at 25 °C
Power SupplyBuilt-in 3.7 V rechargeable Li-ion battery
Battery Life≥40 h per charge
IP RatingIP68
Dimensions (Transmitter)123 mm × 86 mm × 267 mm (L×W×H)
Weight (Transmitter)1.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-8630
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-1305
Instrument TypeOnline Water Quality Analyzer
Measurable ParametersConductivity, pH, Dissolved Oxygen (DO)
Display Resolution0.01 NTU (Turbidity), 0.1 °C (Temperature)
Measurement Accuracy±5% of reading (turbidity), ±0.5 °C (temperature)
Output SignalsDual isolated 4–20 mA (or 0–10/0–20 mA), max. 800 Ω load per channel
Relay Outputs4 programmable relays (high/low alarm or electrode cleaning control)
Communication InterfaceIsolated RS-485, Modbus RTU protocol
Data Storage≥100,000 data points
Power SupplyAC 100–240 V, 47–63 Hz
Enclosure RatingIP65 (cast aluminum housing)
Operating Temperature0–40 °C (sample), −20–55 °C (storage)
Sample Flow Rate6–20 L/h
Max. Suspended Solid Size≤5 µm (no colloids or oils)
Response Time≤30 s
Power Consumption≤12 W
Weight6 kg
Mounting OptionsPanel-mount, wall-mount, pipe-clamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-118W
TypeOnline Analyzer
Measurement PrincipleMolybdenum Blue Spectrophotometry (810 nm LED光源)
Range0–200 μg/L or 0–2000 μg/L (selectable)
Accuracy±2% FS
Repeatability≤1%
Measurement Cycle10–60 min (programmable)
Sample Flow Rate150–300 mL/min
Sample Temp.5–50 °C
Sample Pressure14–140 kPa
Particle Limit≤5 µm (no colloids)
Photometric StabilityBaseline drift eliminated via patented blank compensation
Temperature ControlSample, optical path & reagent maintained at up to 50 °C
Output4–20 mA (isolated), RS485 standard, HART/Profibus optional
Data StorageHigh-capacity internal logging with trend curve recall
PowerAC 220 V ±10%, 50 Hz, max. 240 W
Dimensions450 × 690 × 225 mm (W×H×D)
Weight23 kg (dry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZFSC-I
Price RangeUSD 70,000–100,000 (FOB)
Instrument TypeOnline Water Quality Analyzer
Measured ParameterDissolved Hydrogen
Display Resolution0.01 µg/L
Measurement Range0–10 µg/L and 0–100 µg/L
Accuracy±3% FS or ±0.5 µg/L (whichever is greater)
Response Time (T90)5 s
Temperature Compensation Range5.0–45.0 °C (manual/automatic)
Sample Temp. Range5.0–45.0 °C
Flow Rate50–350 mL/min
Max. Suspended Particle Size≤5 µm (no colloids or oils)
Ambient Temp.5.0–45.0 °C
Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Max. Power Consumption≤500 W
Insulation Strength1500 VAC for 1 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-8610
PriceUpon Request
Dimensions (Single-Channel)760 × 670 × 753 mm
Dimensions (Multi-Channel)1540 × 560 × 1360 mm
Input Voltage220 VAC, 50 Hz
Power Consumption≤180 W (Single), ≤300 W (Multi)
Touchscreen7-inch (Single), 10-inch industrial HMI
Turbidity Sensor Range0–100 NTU
Pressure Sensor Range0–1.6 MPa
pH Sensor Range0–14
Filtration Volume Setting Range0–9999 L
Filtration Pump Flow Rate1.2 L/min
Sedimentation Processing Time (excl. settling)≤15 min per 10 L sample
Vacuum Pump Speed0–12 L/min, Ultimate Vacuum: 24 kPa
Recovery Rate≥30%
Microscope Optical SystemVIS60 Infinity-Corrected, Parfocal Distance ≥60 mm
Stage Travel125 × 75 mm, Minimum Step: 0.1 µm
Fine Focus Resolution1 µm
Camera Resolution2448 × 2048 grayscale
DIC CompatibilityYes
ExpandabilityDarkfield, Phase Contrast, Polarization, Multi-user Viewing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
ModelHK-2301
TypePortable / Handheld Water Quality Analyzer
Measurement ParameterspH, ORP, Conductivity, TDS, Salinity, Temperature
Display3.5-inch color LCD
pH Range0.00–14.00
pH Resolution0.01
pH Accuracy±0.02
ORP Range−2000 to +2000 mV
ORP Resolution0.01 mV
ORP Accuracy±1% FS
Conductivity Range0.00–20.00 mS/cm (with selectable cell constants K = 0.01, 0.1, 1.0, 10.0 cm⁻¹)
TDS Range0.00–80.0 g/L (based on 0.5–0.8 conversion factor)
Salinity Range0.00–80.0 ppt
Temperature Range0.0–99.9 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.5 °C
Temperature CompensationAutomatic (0.0–60.0 °C), adjustable coefficient (0.0–60.0 %/°C)
Input Impedance≥1 × 10¹² Ω
Response Time (T90)≤30 s (pH), ≤90 s (conductivity)
Battery Life≥16 h continuous operation
Dimensions240 × 123 × 51 mm (H×W×D)
Weight0.5 kg
Operating Environment5–45 °C, ≤93% RH (non-condensing)
Storage Temperature−25 to +55 °C (electrodes stored separately above 0 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelHK-8520
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleNessler Reagent Spectrophotometry (in accordance with HJ 535–2009)
Measurement Range0–50 mg/L NH₃–N (extendable to 60 mg/L via built-in dilution algorithm)
Detection Limit0.1 mg/L
Accuracy±(5% of reading + 0.1 mg/L)
Repeatability±5% RSD
Measurement Time15–20 min per sample
Batch Capacity16 samples
Display7-inch capacitive touchscreen (Chinese/English switchable)
Data StorageUp to 100,000 records (measurements, calibrations, system logs)
InterfaceUSB 2.0 for data export
Temperature ControlIntegrated thermostatic cuvette chamber
Light SourceImported monochromatic LED (peak wavelength ~420 nm)
Optical SystemPatented dual-beam ratio-metric photometric path
Calibration Options1-, 2-, or multi-point calibration with user-defined standards
Auto-Stabilization DetectionReal-time signal convergence assessment
Dimensions390 × 248 × 175 mm
Weight5 kg
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤10 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
ModelHK-318
TypeOnline Dissolved Oxygen Analyzer
Measurement PrinciplePolarographic (Clark-type) Electrochemical Sensor
Range0–20 µg/L, 0–200 µg/L, or 0–20 mg/L (auto-ranging)
Accuracy±1 µg/L or ±1.5% FS (whichever is greater)
Repeatability±1.5% FS
Detection Limit0.1 µg/L or 0.1 mg/L
Resolution0.1 µg/L / 0.1 mg/L
Response Time (T90)≤60 s at 25 °C
Temperature Compensation0–50 °C (automatic or manual)
Temp. SensorThermistor
Temp. Accuracy±0.5 °C
OutputDual isolated 4–20 mA (configurable as 0–10 mA or 0–20 mA), max. load 800 Ω
Alarm Outputs2 programmable relay outputs
CommunicationRS-485, Profibus DP, HART
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
EnclosureCast aluminum, IP65-rated front panel
Dimensions146 × 146 × 154 mm (W × H × D)
Panel Cutout139 × 139 mm
Weight2 kg
Operating Ambient5–45 °C
Storage Temp.−25–55 °C (electrode must be stored >0 °C)
Sample Requirements5–50 °C, flow rate 50–350 mL/min, suspended solids ≤5 µm, no colloids or oil, RH ≤90% non-condensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-378
Price RangeUSD 14,000 – 42,000
Measurement Range0–10 µg/L and 0–100 µg/L
Resolution0.01 µg/L
Accuracy±3% FS or ±0.5 µg/L (whichever is greater)
Response Time (T90)≤5 s
Temperature Compensation Range5.0–45.0 °C (auto/manual)
Sample Flow Rate50–350 mL/h
Sample Temperature Range5.0–45.0 °C
Max. Suspended Particle Size≤5 µm (no colloids or oils)
OutputDual isolated 4–20 mA (configurable as 0–10/0–20 mA)
CommunicationRS485 Modbus RTU, USB data export
Power SupplyAC 100–240 V, 50–60 Hz, ≤8 W
Dimensions (W×H×D)690 × 450 × 215 mm
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
ModelHK-8510
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry (in accordance with HJ/T 399–2007)
Wavelength600 nm
Measurement Range100–1000 mg/L (extendable to 10,000 mg/L via on-board dilution)
Accuracy±5% for COD > 50 mg/L
Repeatability±5%
Detection Limit0.1 mg/L
Analysis Time20 minutes per batch
Batch Capacity16 samples
Display7-inch capacitive touchscreen (Chinese/English switchable)
Data StorageUp to 100,000 records (measurements, calibrations, system logs)
InterfaceUSB 2.0 for data export
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption10 W
Dimensions390 × 248 × 175 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-8530
Instrument TypeBenchtop Laboratory Analyzer
Detection PrincipleSpectrophotometry (Diphenylcarbazide Method)
Target AnalyteHexavalent Chromium (Cr(VI))
Analysis Time20 min
Accuracy±5% of reading
Resolution0.001 mg/L
Detection Range0–50 mg/L (extendable to 60 mg/L via dilution)
LOD0.001 mg/L
Display7-inch TFT LCD touchscreen (Chinese/English switchable)
Temperature ControlIntegrated thermostatic system
Light SourceImported monochromatic LED (540 nm)
Calibration OptionsSingle-point, two-point, or multi-point
Data Storage≥100,000 records (measurements, calibrations, system logs)
InterfaceUSB port for data export
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption10 W
Dimensions390 × 248 × 175 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-298
Price RangeUSD 1,400 – 7,000
Instrument TypeBenchtop Laboratory Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-358 Cation Exchange Bed
TypeOnline Sodium Ion Analyzer
Measurement Range(1.00–8.00) pNa, 0.23 µg/L–2300 mg/L
Detection Limit0.01 pNa or 0.01 µg/L
Response Time (T90)2 min at 25 °C
Accuracy±0.05 pNa or ±5 µg/L (whichever is greater)
Temperature Range(0.00–99.9) °C
Temperature CompensationAutomatic or Manual (0.1–60.0 °C)
Display192 × 64 dot-matrix LCD (English/Chinese selectable)
Resolution0.01 pNa / 0.01 µg/L / 0.1 mV
OutputDual isolated (0–10) mA, (0–20) mA, or (4–20) mA
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
Enclosure Dimensions450 × 690 × 190 mm (W × H × D)
Panel Cutout410 × 645 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-8620
PricingAvailable Upon Request