BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-7000
PricingAvailable Upon Request
Control Channels2 / 4 / 6 / 8 channels
Operating Temperature0–70 °C
Relative Humidity≤93% RH (non-condensing)
Input Signal4–20 mA (calibratable within 2–30 mA)
Display Range0–9999 (numeric), or time format (YYYY-MM-DD HH:MM:SS)
Analog Bar Graph0–100% FS
Communication InterfaceRS-485 digital output
Alarm Relay OutputSPST dry contact, rated AC 220 V / 3 A or DC 24 V / 3 A
Alarm FunctionalityDual-stage audible/visual alarm with time-stamped event lockout
Data RetentionNon-volatile memory for operational history (power-on/off, alarm, fault, reset, calibration)
Local CalibrationSupported for connected transmitters
ComplianceGB 16808–1997
Measurement Accuracy±1% FS
Display Resolution1 digit
Alarm Setpoint Range0–9999 (user-configurable)
Display ModeDual-channel — numeric LED + analog bar graph
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHK-7200A
PriceUpon Request
Detection PrincipleMetal Oxide Semiconductor (MOS)
DisplayOLED, Bilingual (Chinese/English)
Operating Temperature-40 °C to +70 °C
Atmospheric Pressure Range86–106 kPa
Measurement Range Options0–100 ppm, 0–200 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm
Resolution1 ppm
Accuracy±5% FS
Response Time (T90)≤30 s
Alarm OutputDual-level visual (LED) and relay
Signal Outputs4–20 mA, CAN bus, RS485
Transmission Distance4–20 mA ≤1000 m (2.5 mm² cable), CAN ≤10 km, RS485 ≤1.2 km
Power SupplyDC 18–30 V
Wiring3-wire or 4-wire configuration
Power Consumption≤2 W
Explosion ProtectionEx d IIC T6 Gb
Ingress ProtectionIP66
Compliance StandardGB 12358–2006
Sampling MethodNatural diffusion
Sensor InterfaceHot-swappable, plug-and-play MOS sensor module
Firmware Architecture32-bit embedded microcontroller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
ModelHK-7200A/7201
Instrument TypeFixed-mount (online) gas detector
Detectable GasesHCN, CO, and other toxic gases
Response Time (T90)≤15 s
Measurement Accuracy±1% FS
Measurement Range(0–100)% LEL
Detection PrinciplesInfrared (IR), Electrochemical (EC), Metal Oxide Semiconductor (MOS), Photoionization Detection (PID)
DisplayDual-language OLED (Chinese/English)
Output Signals4–20 mA analog + optional RS485 Modbus RTU
Power SupplyDC 18–30 V
Enclosure RatingIP66
Explosion ProtectionExd II CT6Gb
Compliance StandardsGB 15322.1–2003, GB 12358–2006
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelDigital Multi-Principle Gas Detector Platform (5 Sensing Technologies)
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
ModelHK-7100A / HK-7101
Instrument TypeFixed Online Gas Detector
Detectable GasesCH₄, CO₂, HC (hydrocarbons), and other combustible/toxic gases
Measurement PrincipleInfrared (IR) and Catalytic Bead (Pellistor)
Response Time (T90)≤10 s (catalytic), ≤15 s (IR)
Accuracy±3% FS (full scale)
Measurement RangeCH₄: 0–100% LEL
CO₂0–5000 ppm, 0–2%, 0–5%, or 0–100% vol (configurable)
DisplayDual-language OLED (Chinese/English)
Output Signal4–20 mA analog + optional RS485 Modbus RTU
Power SupplyDC 18–30 V (bus- or zone-powered)
Enclosure RatingIP66
Operating Temperature−40 °C to +70 °C
Explosion ProtectionEx d II C T6 Gb
ComplianceGB 15322.1–2003
Wiring3-wire or 4-wire
Power Consumption≤5 W
Atmospheric Pressure Range86–106 kPa
Transmission Distance4–20 mA ≤1000 m (2.5 mm² cable)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
Detection PrincipleCatalytic Combustion
Model VariantHK-7100A (Catalytic Bead Configuration)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHK-7000
PricingAvailable Upon Request
Input Signal4–20 mA (calibratable within 2–30 mA)
Display4-digit LED (0–9999), real-time clock (YYYY-MM-DD HH:MM:SS), bar-graph %FS indication
OutputRS-485 Modbus RTU digital interface
Relay OutputsSPST dry contact, rated AC220V/3A or DC24V/3A
Operating Temperature0–70 °C
Relative Humidity≤93% RH (non-condensing)
Data RetentionNon-volatile memory with power-loss-proof event logging (“black box”)
Enclosure OptionsWall-mounted unit or modular rack-mount cabinet (10–60 channels)
Dimensions (Unit)80 × 210 × 60 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelHK-7200A Digital Multi-Principle Gas Detector
PricingAvailable Upon Request
Detection PrinciplePhotoionization (PID)
Measurement Range0–20 ppm, 0–100 ppm, 0–200 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm
Resolution1 ppm
Accuracy±3% FS
Response Time (T90)≤30 s
Operating Temperature−40 to +55 °C
Atmospheric Pressure Range86–106 kPa
Output Signals4–20 mA, CAN Bus, RS485
Max Transmission Distance1000 m (4–20 mA, 2.5 mm²), 10 km (CAN), 1.2 km (RS485)
Supply VoltageDC 18–30 V
Wiring3-wire or 4-wire
Power Consumption≤2 W
Explosion ProtectionEx d IIC T6 Gb
Ingress ProtectionIP66
Compliance StandardGB 12358–2006
DisplayHigh-brightness OLED, bilingual Chinese/English interface
Operation ModesMagnetic stylus & bidirectional infrared remote
Sensor InterfaceHot-swappable, auto-diagnostic, multi-principle sensor platform (PID, electrochemical, catalytic bead, infrared, MOS)
Compatible GasesVOCs and selected toxic gases (e.g., benzene, toluene, xylene, styrene, acetone, isopropanol, chlorinated hydrocarbons)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-7000
PricingAvailable Upon Request
Display320×240 dot-matrix LCD with Chinese interface, 8 channels per screen, configurable screen refresh interval (1–9 sec)
Measurement RangeDependent on connected detector type
Accuracy±1% F.S.
Maximum Detector Capacity32 units
Alarm LevelsDual-stage (Level 1 & Level 2), user-configurable thresholds
Alarm Output8 shared relays for 32-channel alarm and fault signaling (DC 24 V / 5 A or AC 220 V / 5 A)
Operating Temperature0–40 °C
Operating Humidity≤93% RH at 40 °C (non-condensing)
Atmospheric Pressure86–106 kPa
Input SignalCAN bus or 4–20 mA analog
Maximum Communication Distance≤10 km
Power SupplyAC 220 V ±15%, 50/60 Hz
Detector Power OutputDC 24 V (max. 5 A)
Backup Power2 × 12 V / 7 Ah sealed lead-acid batteries
Power Consumption≤150 W
Compliance StandardQ/HDHKY023-2006
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
Detection PrincipleNon-Dispersive Infrared (NDIR)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelHK-7501
Price RangeUSD 14,000 – 42,000
Instrument TypeOnline Analyzer
Measurement MethodNessler Reagent Spectrophotometry
Measurement Range0–10 mg/m³ (customizable)
Detection Limit0.05 mg/m³
Zero Drift±1% FS/month
Cycle Time5 min
Heating Temperature180–240 °C
Sample Flow Rate4–5 L/min
Reagent ConsumptionNessler Reagent 1 L/month, Potassium Sodium Tartrate Solution 0.5 L/month
Ambient Temperature−10 to 50 °C
Power SupplyAC 200–240 V
Power Consumption≤1 kW
Compressed Air0.6–0.8 MPa
Enclosure Dimensions850 × 600 × 1780 mm (L×W×H)
Analog Output1 channel (0–10 mA / 0–20 mA / 4–20 mA, isolated, max load 750 Ω)
Relay Outputs3 channels
Communication InterfaceRS485
Filtration Precision2 µm (metal-ceramic composite membrane)