- All
- Favorite
- Popular
- Most rated
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Model | CellaCast |
| Type | Online Infrared Thermometer |
| Temperature Range | 650–1700 °C |
| Measurement Principle | Two-Color (Ratio) Infrared Radiometry |
| Optical Field of View | Rectangular |
| Special Features | Clean Surface Detection (CSD), Automatic Temperature Detection (ATD), Analog & Serial Data Output, Integrated Alarm Interface, IP65 Housing (with optional air purge & water cooling) |
| Brand | Klocke Nanotechnik |
|---|---|
| Origin | Germany |
| Product Type | Contact-Mode 3D Profilometer / Surface Topography & Roughness Measuring System |
| Measurement Range (X/Y/Z) | 10–50 mm / 10–50 mm / 10–20 mm |
| Extended XY Travel | 100 × 100 mm² or 350 × 350 mm² |
| Motion Resolution | 1 nm |
| Tip Resolution | 0.5 nm |
| Probe Types | Metallic wire tip (radius < 100 nm), hook-type wire tip (radius < 100 nm), spherical tip (Ø 0.12–0.3 mm), diamond tip (for indentation) |
| Sensor Configuration | Dual-axis (horizontal & vertical) capacitive displacement sensors |
| Software Features | Automated tip calibration & approach, 2D/3D visualization, quantitative surface analysis, optional sequence generator for automated measurement routines |
| Brand | Klocke Nanotechnik |
|---|---|
| Origin | Germany |
| Type | Precision Piezo-Based Nanopositioning Platform |
| Model | Klocke Nano Positioning |
| Compliance | Designed for UHV, Cryogenic, and High-Magnetic-Field Environments |
| Max Load Capacity | 2 kg |
| Travel Range | 5–70 mm |
| Velocity | < 2 mm/s |
| Open-Loop Motion Resolution | 2 nm |
| Sensor Resolution (Closed-Loop) | < 10 nm |
| Degrees of Freedom | XYZ linear, Θ/Φ rotation, XY/Z scanning, hybrid coarse/fine modes |
| Customization | Fully configurable mechanical design, material options (Invar, titanium, ceramics), vacuum-compatible variants, integrated metrology interfaces |
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Type | Portable Optical Pyrometer |
| Model | PV11 |
| Temperature Range | 700–3500 °C |
| Minimum Spot Size | 0.1 mm |
| Distance-to-Spot Ratio | up to 5000:1 (e.g., Ø1 mm target at 5 m) |
| Measurement Principle | Visual Intensity Comparison (Two-Color Reference Filament Method) |
| Emissivity Sensitivity | Low |
| Display | Integrated Digital Readout |
| Brand | KELLER |
|---|---|
| Origin | Germany |
| Model | HCW Series |
| Measurement Principle | Two-Color (Ratio) and Single-Wavelength Pyrometry |
| Temperature Range | –30 °C to 3500 °C (model-dependent, segmented calibration) |
| Optical Resolution (Distance-to-Spot Ratio) | Up to 300:1 |
| Spectral Response | 0.8–1.1 µm (short-wave), 1.6 µm, 2.2 µm, or 8–14 µm (depending on model) |
| Output Signals | 4–20 mA, 0–10 V, thermocouple emulation, RS232/RS422/RS485 |
| Environmental Rating | IP65 (standard), optional IP67/IP69K housings |
| Housing Material | Anodized aluminum or AISI 316 stainless steel |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU, IEC 61326-1 (industrial environments) |
| Brand | KELLER MSR |
|---|---|
| Origin | Germany |
| Type | Online Infrared Pyrometer |
| Model | PA Series |
| Optical Configurations | 4 Interchangeable Lenses |
| Target Spot Size | Down to 0.3 mm |
| Distance-to-Spot Ratio | Adjustable via Lens Selection |
| Analog Outputs | 2 (configurable as input/output) |
| Input/Output Flexibility | One analog channel可 configured as process input (e.g., furnace reference compensation) |
| Emissivity Compensation | Adjustable + Custom Correction Curve |
| Environmental Compensation | Transmission loss correction for protective windows, ambient radiation compensation |
| Targeting Options | Eyepiece viewfinder, Class 2 laser pointer, external video camera interface |
| Interface | USB, RS-485 (multi-drop network capable) |
| Display & Control | Integrated LED display + membrane keypad |
| Signal Processing | Adjustable smoothing, linearization, hold functions |
Show next