| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LC-9102 / LC-9103 |
| Pump Type | L-7100 (LC-9102) / L-7150 (LC-9103) |
| Max Pressure | 39.2 MPa (LC-9102) / 20 MPa (LC-9103) |
| Flow Range | 0.001–9.999 mL/min (LC-9102) / 0.01–30.00 mL/min (LC-9103) |
| Gradient Capability | Low-pressure quaternary mixing, linear or multi-segment profiles |
| Flow Precision | <2% RSD at 1 mL/min |
| Column Capacity | Up to four 40 × 600 mm columns |
| Wetted Materials | SUS316, sapphire, ruby, PTFE, PEEK, ceramic, fused silica |
| Power | AC 100–240 V, 50/60 Hz, 800 VA |
| Weight | 100 kg (LC-9102) / 120 kg (LC-9103) |
| Dimensions (W×H×D) | 860 × 675 × 500 mm |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LC-9110NEXT / LC-9130NEXT |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Pressure | 30 MPa (LC-9110NEXT) / 20 MPa (LC-9130NEXT) |
| Flow Rate Range | 0.001–9.999 mL/min (LC-9110NEXT) / 0.01–30.00 mL/min (LC-9130NEXT) |
| Touchscreen Interface | 8.4-inch LCD with capacitive touch |
| Sample Loop Options | 3 mL (std), 5/10 mL (LC-9110NEXT) |
| Auto-Recirculation Cycles | Up to 99 cycles (programmable) |
| Fraction Collection | Standard, up to 33 fractions (time- or signal-triggered) |
| Backflow Prevention | Patented solenoid-valve-based anti-backflow system |
| Maintenance Access | Front-accessible pump, detector, and fluidic modules |
| Power Supply | 85–240 V AC, 800 VA |
| Dimensions (W×H×D) | 464 × 492 × 504 mm |
| Weight | ~38 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LC-9210NEXT / LC-9225NEXT |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Pump Type | Dual-Piston Reciprocating Pump |
| Max Pressure | 25 MPa (LC-9225NEXT), 20 MPa @ 0.1–9.9 mL/min (LC-9210NEXT) |
| Flow Rate Range | 0.01–10.0 mL/min (LC-9210NEXT), 0.1–25.0 mL/min (LC-9225NEXT) |
| Injector | Rheodyne 7725i with 3 mL standard loop (5/10 mL optional for LC-9210NEXT |
| Backflow Prevention | Patented electromagnetic valve-based anti-backflow system |
| Auto-Cleaning | Programmable solvent flush module |
| Control Interface | Dedicated function keys for pump, detector, fraction collection, cycle initiation, and cleaning sequence |
| Dimensions (W×H×D) | 464 × 492 × 504 mm |
| Weight | ~38 kg |
| Power Supply | 85–240 V AC, 800 VA |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LaboACE LC7080 |
| Application Level | Laboratory-grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0.1–80.0 mL/min |
| Flow Accuracy | CV < 0.3% |
| Flow Precision (Repeatability) | CV < 0.3% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ≤0.00005 AU (at 254 nm, 1 s time constant) |
| Data Acquisition Rate | 50–100 Hz |
| Footprint | 382 mm (W) × 432 mm (D) |
| Recycling Capability | Fully Automated Solvent-Saving Loop Mode with Real-Time Fraction Re-injection Logic |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | LC-9104 |
| Pump Type | Dual-piston reciprocating high-pressure solvent delivery system |
| Max. Pressure | 20 MPa (0.01–15.00 mL/min), 15 MPa (15.01–25.00 mL/min), 10 MPa (25.01–30.00 mL/min) |
| Flow Rate Range | 0.01–30.00 mL/min |
| Injection Volume | 100 µL–50 mL (manual Rheodyne 7725i with 10 mL loop standard) |
| Column Compatibility | Up to four 20×600 mm or four 40×600 mm preparative columns |
| Fraction Collector | FC-339, touchscreen-controlled, up to 33 fractions, waste/fraction flow switching |
| Solvent Reservoir | One 5 L bottle |
| Wetted Materials | SUS316 stainless steel, ruby/sapphire, ceramic, PTFE, fluororesin, fused silica |
| Dimensions (W×H×D) | 560×675×500 mm |
| Power | AC 100–115 V / 200–240 V, 50/60 Hz, 800 VA |
| Weight | 70 kg (fully loaded) |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | High-Pressure Preparative HPLC |
| Model | LC-250HS |
| Pump | K-200 Dual-Piston Reciprocating Pump |
| Max Pressure | 10 MPa |
| Flow Rate Range | 2–199 mL/min |
| Flow Accuracy | ±2% |
| Injector | Syringe Pump with 1–160 mL Loop Selection |
| Column Oven | Electric Heating, 5–80 °C |
| Detector | UV-310B Variable-Wavelength UV Detector (195–370 nm, 0.5 mm Pathlength, 20 µL Cell, Noise: 5×10⁻⁵ AU) |
| Fraction Collector | JHF-122 (90 Fractions, Time/Peak/Programmed Collection) |
| Control System | Touchscreen PLC Interface |
| Dimensions (W×H×D) | 760×750×690 mm |
| Weight | 98 kg |
| Wetted Materials | SUS316, Sapphire, Ruby, Ceramic, PTFE, Fluororesin, Fused Silica |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LaboACE LC-5060 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–60.0 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision (Repeatability) | RSD ≤ 0.1% |
| Maximum Operating Pressure | 20 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 1 nm |
| Baseline Noise | 0.001 AU/hr |
| Data Acquisition Frequency | 50 Hz |