Empowering Scientific Discovery

Beijing Jia Yi (JAI-CHINA) Analytical Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelSW-8400 (for 6"/8" wafers) & SW-12400 (for 12" wafers)
Instrument TypeSecondary Thermal Desorber
Desorption Temperature RangeAmbient to 500 °C
Desorption Recovery Rate70%
Sample Capacity1 wafer per run
Sealing MaterialPolyimide O-ring (220 mm ID)
CoolingIntegrated water-circulation system
Safety FeaturesOverheat protection (15 A/30 mA), interlock mechanism, emergency stop button (red mushroom type), optional water-leak sensor
Power SupplySingle-phase AC 200 V, 15 A and AC 100 V, 20 A
Dimensions (W×H×D)1140 × 1106 × 750 mm
Weight280 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelLC-9102 / LC-9103
Pump TypeL-7100 (LC-9102) / L-7150 (LC-9103)
Max Pressure39.2 MPa (LC-9102) / 20 MPa (LC-9103)
Flow Range0.001–9.999 mL/min (LC-9102) / 0.01–30.00 mL/min (LC-9103)
Gradient CapabilityLow-pressure quaternary mixing, linear or multi-segment profiles
Flow Precision<2% RSD at 1 mL/min
Column CapacityUp to four 40 × 600 mm columns
Wetted MaterialsSUS316, sapphire, ruby, PTFE, PEEK, ceramic, fused silica
PowerAC 100–240 V, 50/60 Hz, 800 VA
Weight100 kg (LC-9102) / 120 kg (LC-9103)
Dimensions (W×H×D)860 × 675 × 500 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelJHI-07
Pyrolyzer TypeMicrofurnace Pyrolyzer with Curie-Point Capability
Dual-Mode OperationCurie-Point & Microfurnace
EGA SupportYes
Quick-Release InterfaceYes
Column Head Cooler CompatibilityCIC-07 (Liquid Nitrogen Cooled)
Re-analysis Kit IncludedTenax GR Trap System for Targeted Peak Re-injection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSD-900
PricingAvailable Upon Request
Distillation MethodSimple Distillation
Heating MethodElectric Oil Bath
Temperature Control RangeAmbient to 78 °C
Distillation Vessel MaterialSUS316 with PTFE Coating
Distillation Vessel Capacity19 L (Usable Volume: ~15 L)
Cooling TowerGlass Ball Condenser, 500 mm Height
Temperature ControllerDigital PID Display
Timing FunctionDigital Stopwatch
N₂ Pressure ControlIntegrated Digital Pressure Sensor
Heater TypeStirred Oil Bath Heater
Power Rating1.5 kW
Control LogicSequential Automated Control
Transfer PumpElectromagnetic Gear Pump (Max Flow: 1.5 L/min)
ValvesFour 3-Way Solenoid Valves
Emergency ShutdownManual Master Power Cut-off Button
Tubing & FittingsPTFE Tubing, PTFE Connectors, SUS316/SUS303 Hardware
Dimensions (W×H×D)600 × 1530 × 480 mm
Electrical SupplySingle-phase AC 200 V / 10 A or AC 100 V / 5 A
Net Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelLC-9110NEXT / LC-9130NEXT
Instrument TypeHigh-Pressure Preparative Liquid Chromatograph
Maximum Pressure30 MPa (LC-9110NEXT) / 20 MPa (LC-9130NEXT)
Flow Rate Range0.001–9.999 mL/min (LC-9110NEXT) / 0.01–30.00 mL/min (LC-9130NEXT)
Touchscreen Interface8.4-inch LCD with capacitive touch
Sample Loop Options3 mL (std), 5/10 mL (LC-9110NEXT)
Auto-Recirculation CyclesUp to 99 cycles (programmable)
Fraction CollectionStandard, up to 33 fractions (time- or signal-triggered)
Backflow PreventionPatented solenoid-valve-based anti-backflow system
Maintenance AccessFront-accessible pump, detector, and fluidic modules
Power Supply85–240 V AC, 800 VA
Dimensions (W×H×D)464 × 492 × 504 mm
Weight~38 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelJHP-22
Instrument TypeCurie-Point Pyrolyzer
Heating MethodHigh-Frequency Induction with Curie-Point Ferromagnetic Foil
Sample TubeQuartz, 4.5 mm ID (Pyrolysis Chamber)
Furnace Temperature RangeAmbient to 200 °C
Pyrolysis Duration1–99 s
Transfer Line Temperature RangeAmbient to 300 °C, Length: 0.7 m
RF Power Output48 W
Flow Path SwitchingSolenoid Valve
Dimensions (W×H×D)305 × 190 × 465 mm
Weight18 kg
Power SupplyAC 100 V, 7 A
GC CompatibilityUniversal GC Interface (Excluding Proprietary Direct-Coupled Systems)
Optional Curie Temperatures1040, 920, 764, 740, 670, 650, 590, 500, 485, 445, 423, 386, 358, 333, 315, 280, 255, 235, 220, 170, 160 °C
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelJPS-700
Instrument TypeCurie-Point Pyrolyzer
Maximum Sample Capacity40 samples
Pyrolysis Temperature RangeUp to 400 °C (typical operating range ≤300 °C)
Heating MethodHigh-Frequency Induction
RF Frequency600 kHz
RF Power Output48 W
Pyrolysis Duration Control1–9,999 s
Inter-Analysis Interval0.01–999.99 min
Carrier Gas PurgeDual-point dry air purge (pressure ≥0.4 MPa)
GC InterfaceUniversal GC-mount adapter
ComplianceCompatible with ASTM D7250, ISO 11348, and USP <621> chromatographic system integration requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelRI-7s
Detector TypeDifferential Refractometer (RID)
Flow Cell Volume8 µL
Refractive Index Range1.00–1.75
Attenuation Settings1–2000 and ∞ (12-step)
Temperature ControlFixed at 34 °C, max 50 °C
Reference Cell CleaningSolenoid-valve actuated
Integrator Output1 V
Recorder Output100 mV / 10 mV
Zero AdjustmentAutomatic
Dimensions (W×H×D)160 × 210 × 400 mm
Power SupplyAC 85–135 V, 50/60 Hz, 200 VA
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelLC-9210NEXT / LC-9225NEXT
Instrument TypeHigh-Pressure Preparative Liquid Chromatograph
Pump TypeDual-Piston Reciprocating Pump
Max Pressure25 MPa (LC-9225NEXT), 20 MPa @ 0.1–9.9 mL/min (LC-9210NEXT)
Flow Rate Range0.01–10.0 mL/min (LC-9210NEXT), 0.1–25.0 mL/min (LC-9225NEXT)
InjectorRheodyne 7725i with 3 mL standard loop (5/10 mL optional for LC-9210NEXT
Backflow PreventionPatented electromagnetic valve-based anti-backflow system
Auto-CleaningProgrammable solvent flush module
Control InterfaceDedicated function keys for pump, detector, fraction collection, cycle initiation, and cleaning sequence
Dimensions (W×H×D)464 × 492 × 504 mm
Weight~38 kg
Power Supply85–240 V AC, 800 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelUV-3702
Detector TypeUltraviolet-Visible (UV-Vis) Detector
Wavelength Range195–600 nm
Optical SystemDual-beam
Light SourceDeuterium Lamp
Noise≤0.00005 AU
Drift≤0.0005 AU/hr
Flow Cell Pathlength0.5 mm (standard), 0.2 mm / 1.0 mm optional
Flow Cell Volume20 µL
Full-Scale Output100 mV / 10 mV
Auto-Zero FunctionYes
Dimensions (W×H×D)156 × 225 × 450 mm
Power SupplyAC 85–135 V, 50/60 Hz, 200 VA
Weight14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Instrument TypeDual-Stage Thermal Desorber
Heating MethodCurie-Point (Standard 280 °C) + Resistive (–99 °C to 350 °C)
CoolingLiquid Nitrogen (–99 °C)
Sample CapacityUp to 48 sequential analyses (15 PAT tubes + programmable repeat/swap logic)
PAT Tube Dimensions12 mm ID × 50 mm height, 10 mL internal volume
Transfer Line Temp RangeAmbient +10 °C to 300 °C
GC InterfaceDirect column connection or syringe-type injection
Power SupplyAC 100 V, 50/60 Hz, 15 A
RF Generator600 kHz, 48 W
Dimensions (Main Unit)355 × 210 × 130 mm, 3.1 kg
Liquid Nitrogen Dewar50 L (JTD-505III) / 20 L (JTD-505MIII), 460 mm Ø × 930 mm H, 24.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelJRS-86
Control SystemCPU-controlled
Sample Injection Volume Range100 µL to 50 mL
Injection Interval1–999 minutes
Maximum Number of Repetitive Injections99
Compatible SystemsIntegrated with JAI 9102 and 9103 Recirculating Preparative HPLC Units
ConfigurationRack-mounted, in-line installation at pump suction side
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelUV-3740
Detector TypeUltraviolet-Visible (UV-Vis) Detector
Wavelength Range195–600 nm
Optical DesignDual-beam
Light SourceDeuterium Lamp
Noise≤0.00002 AU
Drift≤0.0005 AU/hr
Flow Cell Pathlength0.5 mm (standard), optional 0.2 mm and 1.0 mm
Flow Cell Volume20 µL
Saturation Concentration4% (with 0.5 mm cell)
Output Signal10 mV full scale
Auto-zero FunctionYes
Dimensions (W×H×D)140 × 140 × 450 mm
Power SupplyAC 85–135 V, 50/60 Hz, 100 VA
Weight8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelLaboACE LC7080
Application LevelLaboratory-grade
Instrument TypeMedium-to-Low Pressure Preparative LC
Flow Rate Range0.1–80.0 mL/min
Flow AccuracyCV < 0.3%
Flow Precision (Repeatability)CV < 0.3%
Maximum Operating Pressure20 MPa
Wavelength Range190–700 nm
Wavelength Repeatability±0.5 nm
Baseline Noise≤0.00005 AU (at 254 nm, 1 s time constant)
Data Acquisition Rate50–100 Hz
Footprint382 mm (W) × 432 mm (D)
Recycling CapabilityFully Automated Solvent-Saving Loop Mode with Real-Time Fraction Re-injection Logic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelLC-9104
Pump TypeDual-piston reciprocating high-pressure solvent delivery system
Max. Pressure20 MPa (0.01–15.00 mL/min), 15 MPa (15.01–25.00 mL/min), 10 MPa (25.01–30.00 mL/min)
Flow Rate Range0.01–30.00 mL/min
Injection Volume100 µL–50 mL (manual Rheodyne 7725i with 10 mL loop standard)
Column CompatibilityUp to four 20×600 mm or four 40×600 mm preparative columns
Fraction CollectorFC-339, touchscreen-controlled, up to 33 fractions, waste/fraction flow switching
Solvent ReservoirOne 5 L bottle
Wetted MaterialsSUS316 stainless steel, ruby/sapphire, ceramic, PTFE, fluororesin, fused silica
Dimensions (W×H×D)560×675×500 mm
PowerAC 100–115 V / 200–240 V, 50/60 Hz, 800 VA
Weight70 kg (fully loaded)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelJHF-122
Fraction Capacity90 positions
Collection ModesTime-based, Peak-triggered, Manual, Memory-programmed
Input SignalsStart/Stop TTL-compatible (10 mV / 1 V threshold)
Output SignalsEvent Marker (TTL)
Program StorageOne dedicated file per collection method
AccessoriesBenchtop mounting stand, 20 × glass collection tubes (standard size), 20 × PTFE inlet tubing, 3-way solenoid valve
Dimensions (W×H×D)286 × 335 × 387 mm
Power SupplyAC 100–240 V, 50/60 Hz, 50 VA
Weight8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelJHP-5
Instrument TypeCurie-Point Pyrolyzer
Heating MethodHigh-Frequency Induction (600 kHz, 48 W)
Pyrolysis Time Range1 s – 99 h
Flow Path SwitchingSolenoid Valve
Sensor Unit Dimensions/Weight90 × 280 × 160 mm / 2.5 kg
RF Power Supply Dimensions/Weight160 × 250 × 380 mm / 8 kg
Power InputAC 100–240 V, 5 A
GC CompatibilityUniversal (all standard GC systems, excluding proprietary non-standard interfaces)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelJSP-20
Sample Capacity1–20 vials
Injection Volume Range0.1–5.0 mL
Injection PrecisionCV ≤ 1%
Maximum Operating Pressure20 MPa
Injection Repetition1–99 times per vial
Sequence Programmability1–20 order
Maximum Run Time999 minutes
Wash ModeDual solvent/air flush
Vial Type5 mL screw-thread glass vials
Sealing MaterialsSilicone and PTFE
Needle DesignDual-side-port stainless steel needle
Power SupplyAC 100 V / 3 A
Control InterfaceTouchscreen LCD panel
Dimensions (W×H×D)250 × 300 × 435 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelUV-310
Wavelength Range195–370 nm
Detection PrincipleDual-Beam UV Absorbance
Light SourceDeuterium Lamp
Noise≤0.00005 AU
Drift≤0.002 AU/hr
Flow Cell Pathlength0.5 mm (standard), optional 0.2 mm and 1.0 mm
Flow Cell Volume20 µL
Maximum Sample Concentration Tolerance4% (with 0.5 mm cell)
Output Signals100 mV and 10 mV analog outputs
Zero AdjustmentDual-stage coarse + fine tuning
Dimensions (W×H×D)156 × 225 × 450 mm
Power SupplyAC 85–135 V, 50/60 Hz, 200 VA
Weight14 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Instrument TypeUV Detector (UVD)
WavelengthFixed at 254 nm
Detection PrincipleDual-Beam Filter Photometry
Light SourceLow-Pressure Mercury Lamp
Noise≤0.00015 AU
Drift≤0.002 AU/hr
Flow Cell Pathlength0.5 mm (standard), optional 0.2 mm and 1.0 mm
Flow Cell Volume20 µL
Maximum Sample Concentration Tolerance4% (with 0.5 mm cell)
Output Signal100 mV full scale
Zero AdjustmentManual potentiometer
Dimensions (W×H×D)150 × 120 × 370 mm
Power SupplyAC 85–240 V, 50/60 Hz, 200 VA
Weight4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
ModelUV-4ch DAD Detector
Detection PrincipleDiode Array Detection (DAD)
Wavelength Range190–840 nm (operational range 200–800 nm)
Simultaneous Channels4 independent wavelength channels
Light SourceDeuterium lamp + Tungsten-halogen lamp
Flow Cell Options0.3 mm (standard), 1.4 mm, 2.4 mm pathlength
Sensitivity5 × 10⁻⁵ AUFS
Drift≤ 1 × 10⁻³ AU/h
Zero AdjustmentAutomatic
Software CompatibilityJAI Scan, Clarity™ (Windows Vista)
Power SupplyDirect LC system power
Dimensions (W×H×D)150 × 157 × 337 mm
Weight~6.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelUV-50
Instrument TypeUltraviolet Detector (UVD)
Wavelength Range200–380 nm (selectable via interchangeable interference filters)
Standard Wavelength254 nm
Detection MethodDual-Beam Filter Photometry
Light SourceDeuterium Lamp
Noise≤0.00005 AU
Drift≤0.002 AU/hr
Flow Cell Path Length0.5 mm (standard), optional 0.2 mm or 1.0 mm
Flow Cell Volume20 µL
Saturation Concentration4% (at 0.5 mm path length)
Output Signals100 mV and 10 mV full-scale analog outputs
Zero AdjustmentAutomatic
Dimensions (W×H×D)150 × 120 × 420 mm
Power SupplyAC 85–135 V, 50/60 Hz, 100 VA
Weight8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Instrument TypeHigh-Pressure Preparative HPLC
ModelLC-250HS
PumpK-200 Dual-Piston Reciprocating Pump
Max Pressure10 MPa
Flow Rate Range2–199 mL/min
Flow Accuracy±2%
InjectorSyringe Pump with 1–160 mL Loop Selection
Column OvenElectric Heating, 5–80 °C
DetectorUV-310B Variable-Wavelength UV Detector (195–370 nm, 0.5 mm Pathlength, 20 µL Cell, Noise: 5×10⁻⁵ AU)
Fraction CollectorJHF-122 (90 Fractions, Time/Peak/Programmed Collection)
Control SystemTouchscreen PLC Interface
Dimensions (W×H×D)760×750×690 mm
Weight98 kg
Wetted MaterialsSUS316, Sapphire, Ruby, Ceramic, PTFE, Fluororesin, Fused Silica
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJAI
OriginJapan
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelLaboACE LC-5060
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0.1–60.0 mL/min
Flow AccuracyRSD ≤ 0.5%
Flow Precision (Repeatability)RSD ≤ 0.1%
Maximum Operating Pressure20 MPa
Wavelength Range±1 nm
Wavelength Repeatability1 nm
Baseline Noise0.001 AU/hr
Data Acquisition Frequency50 Hz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0