| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | RI-7s |
| Detector Type | Differential Refractometer (RID) |
| Flow Cell Volume | 8 µL |
| Refractive Index Range | 1.00–1.75 |
| Attenuation Settings | 1–2000 and ∞ (12-step) |
| Temperature Control | Fixed at 34 °C, max 50 °C |
| Reference Cell Cleaning | Solenoid-valve actuated |
| Integrator Output | 1 V |
| Recorder Output | 100 mV / 10 mV |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 160 × 210 × 400 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 12 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-3702 |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 195–600 nm |
| Optical System | Dual-beam |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.0005 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), 0.2 mm / 1.0 mm optional |
| Flow Cell Volume | 20 µL |
| Full-Scale Output | 100 mV / 10 mV |
| Auto-Zero Function | Yes |
| Dimensions (W×H×D) | 156 × 225 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 14 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-3740 |
| Detector Type | Ultraviolet-Visible (UV-Vis) Detector |
| Wavelength Range | 195–600 nm |
| Optical Design | Dual-beam |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00002 AU |
| Drift | ≤0.0005 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Saturation Concentration | 4% (with 0.5 mm cell) |
| Output Signal | 10 mV full scale |
| Auto-zero Function | Yes |
| Dimensions (W×H×D) | 140 × 140 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 100 VA |
| Weight | 8 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-310 |
| Wavelength Range | 195–370 nm |
| Detection Principle | Dual-Beam UV Absorbance |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Maximum Sample Concentration Tolerance | 4% (with 0.5 mm cell) |
| Output Signals | 100 mV and 10 mV analog outputs |
| Zero Adjustment | Dual-stage coarse + fine tuning |
| Dimensions (W×H×D) | 156 × 225 × 450 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 200 VA |
| Weight | 14 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | UV Detector (UVD) |
| Wavelength | Fixed at 254 nm |
| Detection Principle | Dual-Beam Filter Photometry |
| Light Source | Low-Pressure Mercury Lamp |
| Noise | ≤0.00015 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Pathlength | 0.5 mm (standard), optional 0.2 mm and 1.0 mm |
| Flow Cell Volume | 20 µL |
| Maximum Sample Concentration Tolerance | 4% (with 0.5 mm cell) |
| Output Signal | 100 mV full scale |
| Zero Adjustment | Manual potentiometer |
| Dimensions (W×H×D) | 150 × 120 × 370 mm |
| Power Supply | AC 85–240 V, 50/60 Hz, 200 VA |
| Weight | 4 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | UV-4ch DAD Detector |
| Detection Principle | Diode Array Detection (DAD) |
| Wavelength Range | 190–840 nm (operational range 200–800 nm) |
| Simultaneous Channels | 4 independent wavelength channels |
| Light Source | Deuterium lamp + Tungsten-halogen lamp |
| Flow Cell Options | 0.3 mm (standard), 1.4 mm, 2.4 mm pathlength |
| Sensitivity | 5 × 10⁻⁵ AUFS |
| Drift | ≤ 1 × 10⁻³ AU/h |
| Zero Adjustment | Automatic |
| Software Compatibility | JAI Scan, Clarity™ (Windows Vista) |
| Power Supply | Direct LC system power |
| Dimensions (W×H×D) | 150 × 157 × 337 mm |
| Weight | ~6.0 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV-50 |
| Instrument Type | Ultraviolet Detector (UVD) |
| Wavelength Range | 200–380 nm (selectable via interchangeable interference filters) |
| Standard Wavelength | 254 nm |
| Detection Method | Dual-Beam Filter Photometry |
| Light Source | Deuterium Lamp |
| Noise | ≤0.00005 AU |
| Drift | ≤0.002 AU/hr |
| Flow Cell Path Length | 0.5 mm (standard), optional 0.2 mm or 1.0 mm |
| Flow Cell Volume | 20 µL |
| Saturation Concentration | 4% (at 0.5 mm path length) |
| Output Signals | 100 mV and 10 mV full-scale analog outputs |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 150 × 120 × 420 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 100 VA |
| Weight | 8 kg |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | RI-50s |
| Detector Type | Differential Refractometer (RID) |
| Flow Cell Volume | 8 µL |
| Refractive Index Range | 1.00–1.75 |
| Attenuation Range | 1–2000 and ∞ (12-step) |
| Temperature Control | Fixed at 34 °C, max 50 °C |
| Reference Cell Cleaning | Solenoid-valve controlled |
| Integrator Output | 1 V |
| Recorder Output | 100 mV / 10 mV |
| Zero Adjustment | Automatic |
| Dimensions (W×H×D) | 150 × 120 × 360 mm |
| Power Supply | AC 85–135 V, 50/60 Hz, 300 VA |
| Weight | 7 kg |