Empowering Scientific Discovery

Beijing Jinfuhong Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
ModelCA-310
Titration MethodFully Automated Coulometric Titration
Instrument TypeCoulometric Karl Fischer Moisture Analyzer
Measurement Resolution0.01 µg
Water Content Range10 µg – 100 mg
Sensitivity0.1 µg H₂O
Precision±3 µg (for samples containing 10 µg – 1 mg or more water)
Repeatability≤0.3% RSD (for ≥1 mg water)
Maximum Electrolysis Current430 mA
Maximum Titration Rate2.2 mg H₂O/min (36 µg H₂O/sec)
Background CompensationAutomatic real-time correction with continuous display (µg H₂O/sec)
Stirring MethodMagnetic stirring
Cell Capacity150 mL
Display5.7-inch color LCD
Data StorageUp to 200 measurement records
Internal Memory Backup>2 months on full charge
Power SupplyAC 220–240 V, 50/60 Hz, 310 VA
Operating Temperature5–40 °C
Operating Humidity≤85% RH (non-condensing)
Dimensions (Main Unit)330 × 320 × 148 mm
Weight (Main Unit)~5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Instrument TypeCoulometric Karl Fischer Moisture Analyzer
Titration MethodCoulometric (Electrolytic) KF Titration
Endpoint DetectionConstant-Current Polarity Detection
Maximum Electrolysis Current400 mA
Maximum Titration Rate2.1 mg H₂O/min
Background CorrectionAutomatic Drift Compensation (µg/s)
Measurement Range10 µg – 100 mg H₂O
Repeatability±5 µg (for 10–1000 µg), RSD ≤ 0.5% (≥1 mg H₂O)
Sensitivity0.1 µg H₂O
Display2-line × 20-character LCD
Environmental Operating Conditions5–40 °C, ≤80% RH (non-condensing)
Power SupplyAC 230–240 V, 50/60 Hz, 30 VA
Dimensions (W×D×H)280 × 180 × 200 mm
Net Weight4.5 kg (main unit), 6.3 kg (unit + power supply)
Interface OptionsRS-232 for printer, PC, or analytical balance
Calculation Modes%, ppm, mg/g (M/W), auto-unit switching (>1000 ppm → %)
Delayed TitrationProgrammable start time
End SignalOn-screen message + audible alert
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Instrument TypeCoulometric Karl Fischer Titrator
Titration MethodCoulometric Karl Fischer Titration
Endpoint DetectionConstant-Current Polarity Detection
Electrolysis ControlPulse-Modulated Current Control
Max Electrolysis Current400 mA
Max Water Titration Rate2.1 mg H₂O/min
Background CorrectionAutomatic μg/sec Drift Compensation
Water Measurement Range10 μg – 100 mg H₂O
Repeatability±5 μg (for 10–1000 μg), RSD ≤0.5% (≥1 mg H₂O)
Sensitivity0.1 μg H₂O
Display2-line × 20-character LCD (showing moisture content, reagent concentration, titration rate, background drift, elapsed time, and calculation mode)
Connectivity OptionsRS-232 interface for printer, PC, or analytical balance
End SignalVisual alert + audible timer alarm
Delayed TitrationProgrammable start delay (time-based)
Calculation Modes%, ppm, mg/g (M/W)
Operating Temperature5–40 °C
Relative Humidity≤80% RH, non-condensing
Power SupplyAC 230–240 V, 50/60 Hz, 30 VA
Dimensions (H×W×D)200 × 280 × 180 mm
Net Weight4.5 kg (main unit), 6.3 kg (unit + power supply)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
Instrument TypeCoulometric Karl Fischer Titrator
Titration MethodFully Automatic Coulometric Titration
Moisture Measurement Range5 µg – 100 mg H₂O
Detection Limit0.1 µg H₂O
Accuracy±3 µg (for 10–1,000 µg), <0.3% RSD (≥1 mg H₂O)
Maximum Electrolysis Current430 mA
Average Titration Speed2.2 mg H₂O/min (36 µg/s)
Background Drift CompensationAuto-calibrated, displayed in µg/s
Sample Data Storage99 recent results + 20 measurement files + 50 composite files
Display8.4-inch TFT LCD touchscreen
Power SupplyAC 220–240 V, 50/60 Hz
Operating Environment15–40 °C, <85% RH (non-condensing)
Dimensions (main unit)244 × 161 × 215 mm
Weight (main unit)~5.5 kg
Show next