- All
- Favorite
- Popular
- Most rated
| Brand | Axcend |
|---|---|
| Origin | USA |
| Model | Focus LC |
| Instrument Type | Portable Capillary HPLC |
| Detection Principle | UV Absorbance (254 nm standard) |
| Max Operating Pressure | 10,000 psi |
| Power Input | AC 100–240 V, 50/60 Hz, 1.4 A |
| Battery | 12 V DC, 126 Wh LiFePO₄ |
| Runtime | >10 hours per charge |
| Cycle Life | >2,000 charge/discharge cycles |
| Solvent Consumption | <10 mL/week (typical operational use) |
| Cartridge-Based System | Tool-free, modular hardware reconfiguration |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S/40998 |
| Measurement Principle | Atomic Emission Spectrometry (Flame Photometry) |
| Elements Measured (Standard) | Na, K, Ca, Mg |
| Optional Channels | Ba or custom single-element channel |
| Measurement Units | ppm, mmol/L, mEq/L |
| Linear Range | Na/K/Ca 0–200 ppm |
| Detection Limit | 0.2 ppm (Na, K) |
| Sensitivity | 0.4 ppm (Na, K) |
| Precision | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Fuel Gases | Butane, Propane, LPG |
| Air Supply | Oil-free, water-free, particle-free compressed air with buffer tank |
| Optical Design | Fixed interference filters (non-movable) |
| Calibration | Automatic zeroing + single-point memory calibration |
| Software | ATS MiniSoftWin™ (GLP-compliant reporting, multi-point calibration curve generation, method/data archiving, ISO/IEC 17025 report templates) |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | 300GM |
| Spectral Dispersion | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Resolution | 1 nm |
| Sensitivity | 200:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±2 nm |
| Detection Range | 1–800 ppm U |
| Precision | ≤1% CV at 100 ppb U |
| Measurement Cycle Time | 5 s |
| Display | Backlit LCD/LED |
| Interface | RS-232, USB 2.0 |
| Power Supply | ATS/37009: 230 VAC, 50/60 Hz |
| ATS/37010 | 110 VAC, 60 Hz |
| Dimensions | 420 × 280 × 380 mm (L×W×H) |
| Net Weight | 9 kg |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S |
| Detection Elements | Na, K, Li, Ca (standard) |
| Measurement Range | Na/K/Li/Ca: 0–200 ppm |
| Ba | 50–1000 ppm |
| Units | ppm, mmol/L, mEq/L |
| Sensitivity | 0.4 ppm (Na, K) |
| Detection Limit | 0.2 ppm (Na, K) |
| Linearity | Natural logarithmic linearity (R² > 0.999 over full range) |
| Repeatability | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Calibration | One-touch auto-zero and multi-point calibration |
| Operating Temperature | 15–36 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 320 × 400 × 400 mm (L×W×H) |
| Net Weight (Analyzer) | 9 kg |
| Air Compressor Dimensions | 340 × 250 × 350 mm |
| Net Weight (Compressor) | 6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Software Interface | USB 2.0, RS-232, optional Ethernet module |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS109 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Max. Permissible Error | ±10% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±3% FS/24h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (res: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (res: 0.01 vol%) |
| HC Range | 0–15,000 ppm (res: 1 ppm) |
| O₂ Range | 0–25 vol% (res: 0.01 vol%) |
| True CO Range | 0–15 vol% (res: 0.01 vol%) |
| NOₓ Range (optional) | 0–5,000 ppm (res: 1 ppm) |
| AFR | 7–23 (res: 0.1) |
| λ (Lambda) | 0.5–1.5 (res: 0.01) |
| RPM | 0–9,999 rpm (res: 1 rpm) |
| Oil Temperature | 0–150 °C (res: 0.1 °C) |
| Internal Temp | 0–50 °C (res: 0.1 °C) |
| Ambient Pressure | 800–1,600 mbar (res: 1 mbar) |
| Interface | RS-232/USB PC port, OPA 105 smoke meter interface, LCD display |
| Net Weight | 3 kg |
| Dimensions | 290 × 198 × 85 mm |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA-105.LCD |
| Instrument Type | Benchtop (not portable — contradicts “便携式” in source |
| corrected per physical specs | 5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power) |
| Measurement Principle | Light Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%) |
| Max. Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8 h |
| Span Drift | ±3% FS/8 h |
| Repeatability | ±2% FS |
| Measurement Path Length | 240 mm |
| Photodetector | Reflective Photoelectric Cell |
| Heater Temperature Control | Thermostatically stabilized ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | ≤5 min |
| Display | Backlit LCD |
| Interface | RS-232 serial output |
| Power Supply | 12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter |
| Dimensions (W×H×D) | 290 × 198 × 175 mm |
| Net Weight | 5.0 kg |
| Compliance | EEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation) |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS205 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (resolution: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (0.01 vol%) |
| HC Range | 0–15,000 ppm (1 ppm) |
| O₂ Range | 0–25 vol% (0.01 vol%) |
| True CO Range | 0–15 vol% (0.01 vol%) |
| NOₓ Range | 0–5,000 ppm (1 ppm) |
| AFR | 7–23 (0.1) |
| λ | 0.5–1.5 (0.01) |
| RPM | 0–9,999 rpm (1 rpm) |
| Oil Temperature | 0–150 °C (0.1 °C) |
| Internal Temperature | 0–50 °C (0.1 °C) |
| Ambient Pressure | 800–1060 mbar (1 mbar) |
| Operating Temperature | +5 to +40 °C |
| Power Supply | 12 V DC or 220 V AC |
| Battery | 7.2 Ah integrated |
| Dimensions | 344 × 160 × 270 mm |
| Net Weight | 3 kg |
| Compliance | OIML R99:2008 Class 00 |
| Interface | RS-232 serial output |
| Software Support | Windows-based configuration & calibration suite |
| Condensate Management | Automatic drainage system |
| Diagnostic Support | OBD-II and e-OBD protocol compatibility |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TEA4000 |
| Pricing | Upon Request |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL2021 |
| Detection Target | Trace H₂O₂ in Gaseous and Aqueous Matrices |
| Detection Limit | <100 ppt (gas), <100 ng/L (liquid, ≈3×10⁻⁹ mol/L) |
| Linear Range | 100 ppt–3 ppm (gas), 100 ng/L–3 mg/L (liquid) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Calibration | Auto-calibration via integrated liquid H₂O₂ standard or internal gaseous H₂O₂ source |
| Dimensions | 50 cm × 49 cm × 13 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 60 Hz, 110 W |
| Interface | RS-232 |
| Interference Tolerance | O₃ < 1:3500, NO < 1:8000 |
| Sample Handling | Integrated gas stripping, dual-channel configuration, digitally controlled precision peristaltic pump |
| Brand | Absolute Ozone |
|---|---|
| Origin | Canada |
| Model | Magnum200 |
| Ozone Output | 200 g/h (10.6 ppd) |
| Max Ozone Output | 230 g/h (12.2 ppd) |
| Ozone Concentration | 5–12% w/w |
| Operating Pressure | 40 psig (adjustable 30–100 psig) |
| Gas Flow Rate | 0.1–50 slpm |
| Power Supply | 208–230 V AC, ±10%, 50/60 Hz, 3-phase, 10.0 A |
| Max Power Consumption | 1700 W |
| Inlet/Outlet Fitting | 3/8" stainless steel |
| Construction | Brushed stainless steel and aluminum housing |
| Pressure Test | 150 psig leak-tested |
| O₃/O₂ Tubing | PTFE-lined 304 stainless steel and brass |
| Dimensions (H×W×D) | 24 × 16 × 7 in |
| Unit Weight | 51 lbs |
| Shipping Weight | 56 lbs |
| Shipping Dimensions | 26 × 20 × 10 in |
| Brand | Absolute Ozone |
|---|---|
| Origin | Canada |
| Model | Atlas80 |
| Ozone Output | 80 g/h (4.5 ppd) |
| Max Ozone Output | 95 g/h (5 ppd) |
| Ozone Concentration | 5–12% w/w |
| Operating Pressure | 25 psig (adjustable 20–100 psig) |
| Gas Flow Rate | 0.1–20 SLPM |
| Input Power | 120 V ~ ±10%, 50/60 Hz, 9.0 A (single-phase) or 220 V ~ ±10%, 50/60 Hz, 7.0 A (single-phase) |
| Max Power Consumption | 650 W |
| Inlet/Outlet Fitting | 0.25-inch stainless steel compression fittings |
| Construction Materials | Brushed stainless steel and aluminum housing |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL4021 |
| Principle | Photometric Detection via Hantzsch Reaction |
| Measurement Range | 0.1 ppb – 3000 ppb (gas phase), 150 ng/L – 5 mg/L (aqueous phase) |
| Resolution | 0.1 ppb |
| Repeatability | <3% |
| Sampling Method | Pump-aspirated |
| Response Time | 90 s (10–90%) |
| Operating Temperature | 0 °C – 120 °C |
| Humidity Range | 15–95% RH |
| Detection Limit | <100 ppt (gas), <150 ng/L (liquid) |
| Calibration Options | Automated gas-phase calibration (integrated permeation tube generator), semi-automated liquid-phase standard injection |
| Data Storage | USB flash drive (8 GB) |
| Interface | RS232 |
| Dimensions (W×H×D) | 45 × 15 × 56 cm |
| Mounting | 19″ rack-compatible |
| Power Supply | 110/220 VAC, 110 W (24 VDC optional) |
| Brand | Aero |
|---|---|
| Origin | Germany |
| Model | AL2021 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Target | Hydrogen Peroxide (H₂O₂) and Organic Peroxides |
| Linear Range | 100 ppt–3 ppm (gas phase) |
| Detection Limit | 100 ppt (gas) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Dimensions | 50 cm × 49 cm × 13 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 60 Hz, 110 W |
| Communication Interface | RS-232 |
| Interference Tolerance | O₃ < 1:3500 |
| NO < 1 | 8000 |
| Automation | Fully microprocessor-controlled with integrated gas-stripping and precision peristaltic pumping |
| Calibration | Auto-calibration via internal H₂O₂ source or liquid standard |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV) at 150 nm |
| Detection Limit | <2.0 ppb (1 s integration), <0.8 ppb (10 s integration) |
| Response Time (10–90%) | 2 s |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Pump Type | Diaphragm vacuum pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully automated measurement and calibration |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV-F) at 150 nm |
| Detection Limit | <0.8 ppb (10 s integration) |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Response Time (10–90%) | 2 s |
| Pump Type | Diaphragm Vacuum Pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully Automated Zero/Span Calibration |
| Application Scope | Ultra-trace CO monitoring in ambient air, cleanrooms, high-purity specialty gas streams, and remote atmospheric research stations |
| Brand | Absolute Ozone |
|---|---|
| Origin | Canada |
| Model | NANO |
| Ozone Output | 15 g/h (up to 20 g/h) |
| O₃ Concentration | 5–10% by weight |
| Oxygen Flow Rate | 0.1–4 SLPM |
| Operating Pressure | 20 psig |
| Power Input | 120 V ±10% / 220 V ±10%, 50/60 Hz, single-phase |
| Power Consumption | 150–200 W |
| O₂ Inlet & O₃ Outlet | 1/4″ fittings |
| Construction | Brushed stainless steel/aluminum housing |
| Pressure Test | 120 psig leak-tested |
| Dimensions | 5″ × 5″ × 14″ (W × D × H) |
| Weight | 5.8 kg |
| Compliance | CSA-certified (optional) |
| Brand | ABSOLUTE OZONE |
|---|---|
| Origin | Canada |
| Model | Magnum160 |
| Ozone Output | 160 g/h (8.5 ppm·dm³/min) |
| Max Ozone Output | 180 g/h (9.5 ppm·dm³/min) |
| Operating Pressure | 40 psig (adjustable 30–100 psig) |
| O₃ Concentration | 5–12% w/w |
| Gas Flow Rate | 0.1–50 SLPM |
| Power Supply | 208–230 V AC ±10%, 50/60 Hz, 3-phase, 8.0 A |
| Max Power Consumption | 1600 W |
| Inlet/Outlet Fittings | 3/8" stainless steel |
| Construction | Brushed stainless steel & aluminum housing |
| Pressure Test | 150 psig leak-tested |
| Dimensions (H×W×D) | 14 × 26.5 × 7 in |
| Net Weight | 53 lbs |
| Shipping Weight | 58 lbs |
| Shipping Dimensions | 30 × 18 × 11 in |
| Brand | ABSOLUTE OZONE |
|---|---|
| Origin | Canada |
| Model | Atlas100 |
| Ozone Output | 100 g/h (5.3 ppm·day) |
| Max Ozone Output | 113 g/h (6 ppm·day) |
| Ozone Concentration | 5–12% w/w |
| Feed Gas Flow Rate | 0.1–25 SLPM |
| Operating Pressure | 25–100 psig (standard setpoint: 25 psig) |
| Power Supply | 120 V ±10%, 50/60 Hz, single-phase, 15.0 A |
| Max Power Consumption | 950 W |
| Inlet/Outlet Fitting | 0.25-inch stainless steel compression fittings |
| Construction | Brushed stainless steel and aluminum housing |
| O₃/O₂ Conduit Materials | PTFE-lined 304 stainless steel and brass |
| Pressure Test Rating | 150 psig leak-tested |
| Brand | SMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABL |
| Pricing | Available Upon Request |
| Brand | NAVAS INSTRUMENTS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TGA-4000 |
| Price Range | USD 42,000 – 70,000 |
| Temperature Range | 50°C to 1000°C ±1°C |
| Sample Mass Range | 0.1–5 g |
| Weight Resolution | 0.0002 mg (4-digit analytical balance) |
| Sample Capacity | 19 positions (standard), configurable |
| Gas Control | Programmable inert/oxidizing atmosphere (N₂, air, O₂) |
| Interface | USB-connected Windows-based control system |
| Compliance | ASTM D3172, D3173, D3174, D3175, ISO 1171, ISO 562, USP <1225>, GLP/GMP-ready audit trail |
| Brand | JHX |
|---|---|
| Origin | USA |
| Model | TGA-2000 |
| Temperature Range | 50–1000 °C ±1 °C |
| Sample Mass | 0.1–5 g |
| Sample Capacity | 19 positions (configurable) |
| Weight Loss/Gain Range | 0–100% |
| Minimum Weight Resolution | 0.0002 mg |
| Compliance | ASTM D3172, ASTM D7582, ISO 1171, ISO 562, USP <731>, GLP/GMP-Ready Software Audit Trail |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiBlock |
| Function Type | Multi-Block, Gradient-Capable, Touchscreen-Controlled Thermal Cycler |
| Heating/Cooling System | Peltier-based |
| Display | 10-inch Full-Color Adjustable-Tilt Touchscreen |
| Communication Ports | USB 2.0, LAN |
| Temperature Range | 4°C to 99.9°C |
| Max Heating Rate | 7.5°C/sec |
| Max Cooling Rate | 6.0°C/sec |
| Temperature Uniformity | ≤ ±0.2°C at 90°C |
| Temperature Accuracy | ≤ ±0.2°C at 90°C |
| Ramp Rate Adjustment | 0.1–5.0°C/sec |
| Gradient Function | Yes (8-zone independent gradient per block) |
| Gradient Accuracy | ±0.1°C |
| Gradient Range | 30–99.9°C |
| Heated Lid | Yes |
| Lid Temperature Range | 30–112°C |
| Software Features | Password-Protected User Accounts, Protocol Transfer via USB, Audit-Trail-Ready Program Storage, On-Device Protocol Wizard |
| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2440 |
| Temperature Range | Ambient to 210 °C (±0.1 °C stability) |
| Compliance | ASTM D2440, IP 307, ISO 7624, IP 48, IP 280, IP 306, IP 335, EN 61125-A/B/C |
| Construction | Double-walled stainless steel housing with thermal insulation |
| Temperature Control | PID controller with PT100A sensor and over-temperature alarm |
| Heating System | Stainless steel immersion heater |
| Agitation | Motor-driven magnetic stirrer |
| Safety Features | Low-level liquid sensor with visual alarm, drain cock, ventilated lid with ports for flowmeter and absorption tube |
| Power Supply | 220 V, 50/60 Hz |
Show next