| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂ |
| Detection Principle | Optical-feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) |
| Operating Pressure | <100 mbar (absolute) |
| Detection Limits (3σ) | H₂O ≤ 0.01 ppm, CH₄ ≤ 0.001 ppm, O₂ ≤ 5 ppm, CO₂ ≤ 0.2 ppm, CO ≤ 0.001 ppm, H₂S ≤ 0.001 ppm, HCHO ≤ 0.001 ppm, HCOOH ≤ 0.005 ppm, NH₃ ≤ 0.001 ppm, HCl ≤ 0.001 ppm |
| Compliance | T/CECA-G0015-2017 (equivalent to ISO 14687-2:2019) |
| Calibration | Factory-pre-calibrated, integrated auto-zero and span verification |
| Carrier Gas | None required |
| Sample Volume Requirement | Minimal (<10 mL/min at sub-atmospheric pressure) |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX MAX-One™ |
| Type | Portable |
| Response Time | 0.01 s |
| Detection Principle | MEMS-based Micro-Gas Chromatography with μTCD |
| Compliance | ATEX II 2G Ex IIB+H2 T6, CSA Div 1 Class I, Group B, C, D, AEx d IIB+H2 T6, NeSSI-compatible |
| Dimensions | 360 × 350 × 170 mm |
| Weight | 25 kg |
| Power Input | 100–240 V AC, 50–60 Hz |
| Max Power Consumption | 750 W |
| Operating Temperature | −10 to +40 °C |
| GC Column Temp Range | 50–160 °C (stability < 0.1 °C) |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Sample Injection Pressure | 1–15 bar |
| Injection Volume | < 15 µL |
| Detector | Micro-Thermal Conductivity Detector (μTCD), ambient-120 °C |
| Detection Range | sub-ppm to % v/v |
| LOD (typical) | Permanent gases (N₂, CO₂, O₂) < 10 ppm |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | ChromPix 2 |
| Type | Portable GC-based Analyzer |
| Principle | Microfabricated Gas Chromatography with Silicon-based μ-TCD and NEMS Detection |
| Response Time | <0.01 s (detector response) |
| Sample Types | Natural gas, biogas, industrial stack emissions, VOCs (including BTEX), permanent gases (N₂, O₂, CO₂), sulfur compounds (H₂S, THT, mercaptans), and specialty gases |
| Column Capacity | Up to 4 parallel capillary columns |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Operating Temperature | −10–40 °C |
| Power | 100–240 V AC, 50–60 Hz, 150 W (config-dependent) |
| Dimensions | 450 × 460 × 220 mm |
| Weight | 10 kg |
| Column Temp Range | 50–160 °C (stability <0.1 °C) |
| Detection Range | sub-ppm to % v/v |
| LOD (VOCs w/ preconcentration) | <1 ppb |
| LOD (H₂S) | 7 ± 0.7 ppm (with sample conditioning) |
| LOD (THT) | 2 ± 0.2 ppm (with sample conditioning) |
| LOD (C₁–C₆ hydrocarbons) | <5 ppm |
| LOD (C₆–C₁₂) | <1 ppm |
| LOD (N₂/O₂/CO₂) | <10 ppm |
| LOD (BTEX) | <1 ppm |
| Analysis Time | ≤1 min (separation), ≤2 min (incl. backflush) |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCl |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| HCl Detection Limit (3σ, 300 s) | 1 ppb |
| HCl Accuracy (1σ, 300 s) | 0.3 ppb + 0.1% of reading |
| HCl Measurement Range | 0–1000 ppb |
| H₂O Measurement Range | 0–5% |
| H₂O Detection Limit (3σ, 300 s) | 180 ppm |
| Zero Drift (72 h) | ±0.20 ppb |
| Response Time (10–90%) | <300 s |
| Measurement Interval | 2 s |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temp. Range | −10 to +45 °C |
| Max. Sample Humidity | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC Series |
| Pricing | Available Upon Request |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas COS |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 2 ppb |
| Precision (1σ) | 0.6 ppb + 0.5% of reading |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <60 s |
| Measurement Range | 0–10 ppm |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Control | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA / 0–10 V), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCHO |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | <1 ppb |
| Accuracy (1σ) | 0.15 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–10 ppm |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH, non-condensing |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas NH₃ |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.05 ppb |
| Accuracy (1σ) | 0.015 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–1000 ppb (guaranteed), 0–10 ppm (operational) |
| Cavity Volume | 25 mL |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Ambient Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂S |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 1 ppb |
| Accuracy (1σ) | 0.3 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <5 s |
| Measurement Range | 0–5000 ppb |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH, non-condensing |
| Sample Flow Rate | >400 mL/min |
| Output Interfaces | Ethernet, Modbus TCP/IP & RTU, 4–20 mA analog, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Form Factor | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX-PPAM |
| Type | Portable Multicomponent Gas Analyzer Module |
| Principle | Silicon-Microfabricated Gas Chromatography with Integrated NEMS/μTCD Detection |
| Response Time | ≤10 ms (injection) |
| Repeatability | <0.1% RSD for sample injection |
| Sample Compatibility | Natural gas, ambient air, permanent gases, hydrocarbons (C1–C10), VOCs, sulfur compounds, halogenated organics, oxygenates |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Carrier Flow Rate | ~1 mL/min |
| Injection Volume | <15 µL |
| Column Temperature Range | 50–160 °C (stability <0.1 °C) |
| Detector Operating Range | Ambient to 120 °C |
| Detection Range | sub-ppb (with preconcentration) to % v/v |
| Module Dimensions | 27 × 10 × 3 cm |
| Weight | 900 g |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HF |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.015 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | < 300 s |
| Measurement Range | 0–1000 ppb HF |
| Optional Co-measurements | O₂ (0–21%), H₂O (0–5%) |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Pressure Control | ±0.016 mbar |
| Sample Temp. | −10 to +45 °C |
| Sample Humidity | < 99% RH, non-condensing |
| Flow Rate | < 2000 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 408 |
| NO Generation Method | Photolytic decomposition of N₂O at 185 nm |
| Output Concentration Range | 0 and 10–1000 ppb |
| Accuracy | ±3 ppb or ±3% of reading (whichever is greater) |
| Flow Rate | ~3.0 L/min |
| Rise Time | <30 s (to 95% of setpoint) |
| Operating Temperature | 0–40 °C |
| Power Supply | 12 V DC or 120/240 V AC, 21 W |
| Dimensions | 9.4 × 21.6 × 24.1 cm |
| Weight | 2.4 kg |
| Diagnostic Interface | RS-232 |
| Humidity-Matched Output | Yes |
| NIST-Traceable Calibration | Yes |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 306 |
| Instrument Type | Portable |
| Measurement Range | 0 and 30–1000 ppb |
| Response Time | <30 s |
| Ozone Generation Method | Photolysis of O₂ at 185 nm |
| Accuracy | ±2 ppb or ±1% of reading (whichever is greater) |
| Flow Rate | ~3.0 L/min |
| Rise Time | <30 s (to 95% of target concentration) |
| Output Interface | RS-232 |
| Power Supply | 12 V DC or 100–240 V AC, 18 W |
| Dimensions | 9 × 21 × 29 cm |
| Weight | 2.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 405 |
| Detection Principle | UV Absorption Spectroscopy at 405 nm |
| Measurement Range | 0–10,000 ppb NO₂ |
| Resolution | 0.1 ppb |
| Accuracy | ±2.5 ppb or ±2.5% of reading (whichever is greater) |
| Detection Limit (2σ) | 3.5 ppb (60 s avg) |
| Response Time (100%) | 40 s (20 s avg) |
| Operating Temperature | 10–50 °C |
| Power Supply | 11–14 V DC or 100–240 V AC, 26 W |
| Dimensions | 43 × 37 × 14 cm (17″ × 14.5″ × 5.5″) |
| Weight | 8.4 kg (18.6 lb) |
| Data Output | USB, RS-232, 0–2.5 V analog, 4–20 mA analog |
| Internal Memory | 8,192 records |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 205 |
| Measurement Principle | UV Absorption at 254 nm |
| Linear Range | 1 ppbv to 100 ppmv |
| Precision | ±1 ppb or ±2% of reading (whichever is greater) |
| Accuracy | ±1 ppb or ±2% of reading (whichever is greater) |
| Detection Limit | 2 ppb |
| Measurement Interval | 2 s (configurable averaging: 2 s, 10 s, 1 min, 5 min, 1 hr) |
| Response Time (100% step change) | 4 s (2-point) |
| Sample Flow Rate | ~1.8 L/min (nominal), >1.2 L/min (minimum required) |
| Baseline Drift | <1 ppb/day, <3 ppb/year |
| Sensitivity Drift | <1 ppb/day, <3 ppb/year |
| Temperature & Pressure Compensation | Yes |
| Operating Temperature | 0–50 °C (–20–50 °C with optional low-temperature modification kit) |
| Operating Altitude | 0–30 km (30–1000 mbar) |
| Output Units | ppb, ppm, pphm, µg·m⁻³, mg·m⁻³ |
| Data Storage Capacity | 14,336 rows (e.g., 1.4 days at 10-s average |
| Communication Interfaces | RS232 serial, 0–2.5 V analog output, LCD display |
| Dimensions | 9 × 21 × 29 cm |
| Weight | 2.1 kg (instrument only |
| Optional Accessories | GPS module, microSD card, DewLine™ heater lamp, rotary vane pump, external pump, calibration kit |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 410 |
| Measurement Principle | Chemiluminescence-free ozone titration with UV absorption at 254 nm (NOzone™ Technology) |
| Range | 0–2 ppm NO |
| Detection Limit | <1.5 ppb or ±2% of reading, whichever is greater |
| Data Storage | 14,336 rows (e.g., 10-sec averages for ~1.4 days |
| Sampling Flow Rate | 1.0 L/min |
| Measurement Interval | Configurable (10 s, 1 min, 5 min, 1 hr) |
| Output Interfaces | RS-232 serial, 0–2.5 V analog, LCD display, optional microSD card logging |
| Dimensions | 33.7 × 20.0 × 13.3 cm |
| Weight | 8.3 kg (3.7 kg without portable case) |
| Optional Accessory | 401 NO₂ Converter for NOₓ and NO₂ measurement |
| Compliance | Designed for ambient air quality monitoring per EPA TO-15 and ISO 8573-1 referencing traceable gas standards |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 202 |
| Measurement Principle | UV Absorption at 254 nm |
| Linear Range | 1.5 ppbv to 250 ppmv |
| Precision | ±1.5 ppb or ±2% of reading (whichever is greater) |
| Accuracy | ±1.5 ppb or ±2% of reading (whichever is greater) |
| Detection Limit | 3 ppb |
| Measurement Interval | 10 s (user-selectable averaging: 10 s, 1 min, 5 min, 1 hr) |
| Response Time | 20 s for 100% step change (2-point) |
| Sample Flow Rate | ~1 L/min (nominal), ≥0.6 L/min (minimum required) |
| Baseline Drift | <2 ppb/day, <5 ppb/year |
| Sensitivity Drift | <1 ppb/day, <3 ppb/year |
| Temperature & Pressure Compensation | Yes |
| Operating Temperature | 0–50 °C (–20–50 °C with optional low-temperature modification kit) |
| Operating Altitude | 0–30 km (30–1000 mbar) |
| Data Storage Capacity | 14,336 records (e.g., 1.4 days at 10-s average |
| Output Interfaces | RS-232 serial, 0–2.5 V analog, built-in LCD display |
| Dimensions | 9 × 21 × 29 cm |
| Weight | 2.1 kg (host only |
| Compliance | U.S. EPA Federal Equivalent Method (FEM) EQOA-0410-190 |
| Calibration | NIST-traceable |