BrandAPIX Analytics
OriginFrance
ModelAPIX MAX-One™
TypePortable
Response Time0.01 s
Detection PrincipleMEMS-based Micro-Gas Chromatography with μTCD
ComplianceATEX II 2G Ex IIB+H2 T6, CSA Div 1 Class I, Group B, C, D, AEx d IIB+H2 T6, NeSSI-compatible
Dimensions360 × 350 × 170 mm
Weight25 kg
Power Input100–240 V AC, 50–60 Hz
Max Power Consumption750 W
Operating Temperature−10 to +40 °C
GC Column Temp Range50–160 °C (stability < 0.1 °C)
Carrier GasesHe, H₂, N₂, Ar, synthetic dry air
Sample Injection Pressure1–15 bar
Injection Volume< 15 µL
DetectorMicro-Thermal Conductivity Detector (μTCD), ambient-120 °C
Detection Rangesub-ppm to % v/v
LOD (typical)Permanent gases (N₂, CO₂, O₂) < 10 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPIX Analytics
OriginFrance
ModelChromPix 2
TypePortable GC-based Analyzer
PrincipleMicrofabricated Gas Chromatography with Silicon-based μ-TCD and NEMS Detection
Response Time<0.01 s (detector response)
Sample TypesNatural gas, biogas, industrial stack emissions, VOCs (including BTEX), permanent gases (N₂, O₂, CO₂), sulfur compounds (H₂S, THT, mercaptans), and specialty gases
Column CapacityUp to 4 parallel capillary columns
Carrier GasesHe, H₂, N₂, Ar, synthetic dry air
Operating Temperature−10–40 °C
Power100–240 V AC, 50–60 Hz, 150 W (config-dependent)
Dimensions450 × 460 × 220 mm
Weight10 kg
Column Temp Range50–160 °C (stability <0.1 °C)
Detection Rangesub-ppm to % v/v
LOD (VOCs w/ preconcentration)<1 ppb
LOD (H₂S)7 ± 0.7 ppm (with sample conditioning)
LOD (THT)2 ± 0.2 ppm (with sample conditioning)
LOD (C₁–C₆ hydrocarbons)<5 ppm
LOD (C₆–C₁₂)<1 ppm
LOD (N₂/O₂/CO₂)<10 ppm
LOD (BTEX)<1 ppm
Analysis Time≤1 min (separation), ≤2 min (incl. backflush)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPIX Analytics
OriginFrance
ModelAPIX-PPAM
TypePortable Multicomponent Gas Analyzer Module
PrincipleSilicon-Microfabricated Gas Chromatography with Integrated NEMS/μTCD Detection
Response Time≤10 ms (injection)
Repeatability<0.1% RSD for sample injection
Sample CompatibilityNatural gas, ambient air, permanent gases, hydrocarbons (C1–C10), VOCs, sulfur compounds, halogenated organics, oxygenates
Carrier GasesHe, H₂, N₂, Ar, synthetic dry air
Carrier Flow Rate~1 mL/min
Injection Volume<15 µL
Column Temperature Range50–160 °C (stability <0.1 °C)
Detector Operating RangeAmbient to 120 °C
Detection Rangesub-ppb (with preconcentration) to % v/v
Module Dimensions27 × 10 × 3 cm
Weight900 g