- All
- Favorite
- Popular
- Most rated
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX MAX-One™ |
| Type | Portable |
| Response Time | 0.01 s |
| Detection Principle | MEMS-based Micro-Gas Chromatography with μTCD |
| Compliance | ATEX II 2G Ex IIB+H2 T6, CSA Div 1 Class I, Group B, C, D, AEx d IIB+H2 T6, NeSSI-compatible |
| Dimensions | 360 × 350 × 170 mm |
| Weight | 25 kg |
| Power Input | 100–240 V AC, 50–60 Hz |
| Max Power Consumption | 750 W |
| Operating Temperature | −10 to +40 °C |
| GC Column Temp Range | 50–160 °C (stability < 0.1 °C) |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Sample Injection Pressure | 1–15 bar |
| Injection Volume | < 15 µL |
| Detector | Micro-Thermal Conductivity Detector (μTCD), ambient-120 °C |
| Detection Range | sub-ppm to % v/v |
| LOD (typical) | Permanent gases (N₂, CO₂, O₂) < 10 ppm |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | ChromPix 2 |
| Type | Portable GC-based Analyzer |
| Principle | Microfabricated Gas Chromatography with Silicon-based μ-TCD and NEMS Detection |
| Response Time | <0.01 s (detector response) |
| Sample Types | Natural gas, biogas, industrial stack emissions, VOCs (including BTEX), permanent gases (N₂, O₂, CO₂), sulfur compounds (H₂S, THT, mercaptans), and specialty gases |
| Column Capacity | Up to 4 parallel capillary columns |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Operating Temperature | −10–40 °C |
| Power | 100–240 V AC, 50–60 Hz, 150 W (config-dependent) |
| Dimensions | 450 × 460 × 220 mm |
| Weight | 10 kg |
| Column Temp Range | 50–160 °C (stability <0.1 °C) |
| Detection Range | sub-ppm to % v/v |
| LOD (VOCs w/ preconcentration) | <1 ppb |
| LOD (H₂S) | 7 ± 0.7 ppm (with sample conditioning) |
| LOD (THT) | 2 ± 0.2 ppm (with sample conditioning) |
| LOD (C₁–C₆ hydrocarbons) | <5 ppm |
| LOD (C₆–C₁₂) | <1 ppm |
| LOD (N₂/O₂/CO₂) | <10 ppm |
| LOD (BTEX) | <1 ppm |
| Analysis Time | ≤1 min (separation), ≤2 min (incl. backflush) |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX-PPAM |
| Type | Portable Multicomponent Gas Analyzer Module |
| Principle | Silicon-Microfabricated Gas Chromatography with Integrated NEMS/μTCD Detection |
| Response Time | ≤10 ms (injection) |
| Repeatability | <0.1% RSD for sample injection |
| Sample Compatibility | Natural gas, ambient air, permanent gases, hydrocarbons (C1–C10), VOCs, sulfur compounds, halogenated organics, oxygenates |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Carrier Flow Rate | ~1 mL/min |
| Injection Volume | <15 µL |
| Column Temperature Range | 50–160 °C (stability <0.1 °C) |
| Detector Operating Range | Ambient to 120 °C |
| Detection Range | sub-ppb (with preconcentration) to % v/v |
| Module Dimensions | 27 × 10 × 3 cm |
| Weight | 900 g |
Show next