Add to compare
Brand2B Technologies
OriginUSA
Model306
Instrument TypePortable
Measurement Range0 and 30–1000 ppb
Response Time<30 s
Ozone Generation MethodPhotolysis of O₂ at 185 nm
Accuracy±2 ppb or ±1% of reading (whichever is greater)
Flow Rate~3.0 L/min
Rise Time<30 s (to 95% of target concentration)
Output InterfaceRS-232
Power Supply12 V DC or 100–240 V AC, 18 W
Dimensions9 × 21 × 29 cm
Weight2.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
Model205
Measurement PrincipleUV Absorption at 254 nm
Linear Range1 ppbv to 100 ppmv
Precision±1 ppb or ±2% of reading (whichever is greater)
Accuracy±1 ppb or ±2% of reading (whichever is greater)
Detection Limit2 ppb
Measurement Interval2 s (configurable averaging: 2 s, 10 s, 1 min, 5 min, 1 hr)
Response Time (100% step change)4 s (2-point)
Sample Flow Rate~1.8 L/min (nominal), >1.2 L/min (minimum required)
Baseline Drift<1 ppb/day, <3 ppb/year
Sensitivity Drift<1 ppb/day, <3 ppb/year
Temperature & Pressure CompensationYes
Operating Temperature0–50 °C (–20–50 °C with optional low-temperature modification kit)
Operating Altitude0–30 km (30–1000 mbar)
Output Unitsppb, ppm, pphm, µg·m⁻³, mg·m⁻³
Data Storage Capacity14,336 rows (e.g., 1.4 days at 10-s average
Communication InterfacesRS232 serial, 0–2.5 V analog output, LCD display
Dimensions9 × 21 × 29 cm
Weight2.1 kg (instrument only
Optional AccessoriesGPS module, microSD card, DewLine™ heater lamp, rotary vane pump, external pump, calibration kit
Added to wishlistRemoved from wishlist 0
Add to compare
Brand2B Technologies
OriginUSA
Model202
Measurement PrincipleUV Absorption at 254 nm
Linear Range1.5 ppbv to 250 ppmv
Precision±1.5 ppb or ±2% of reading (whichever is greater)
Accuracy±1.5 ppb or ±2% of reading (whichever is greater)
Detection Limit3 ppb
Measurement Interval10 s (user-selectable averaging: 10 s, 1 min, 5 min, 1 hr)
Response Time20 s for 100% step change (2-point)
Sample Flow Rate~1 L/min (nominal), ≥0.6 L/min (minimum required)
Baseline Drift<2 ppb/day, <5 ppb/year
Sensitivity Drift<1 ppb/day, <3 ppb/year
Temperature & Pressure CompensationYes
Operating Temperature0–50 °C (–20–50 °C with optional low-temperature modification kit)
Operating Altitude0–30 km (30–1000 mbar)
Data Storage Capacity14,336 records (e.g., 1.4 days at 10-s average
Output InterfacesRS-232 serial, 0–2.5 V analog, built-in LCD display
Dimensions9 × 21 × 29 cm
Weight2.1 kg (host only
ComplianceU.S. EPA Federal Equivalent Method (FEM) EQOA-0410-190
CalibrationNIST-traceable