Empowering Scientific Discovery

Beijing Pure-Science Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelElement5 870
QuotationUpon Request
PrincipleAdsorption/Desorption with Catalytic Oxidation & C-Quantum Selective Purification
Sample TypeAmbient Air
Output Purity>99.99% CO₂
Yield10–100 mg per run
Cycle Time10–60 min
Detection CompatibilityIRMS (δ¹³C), AMS or CRDS (¹⁴C)
Dual Combustion FurnacesLeft furnace max 500 °C, right furnace max 650 °C
Carrier GasUltra-high-purity He (99.999%, 3–5 bar)
Auxiliary GasUltra-high-purity CO₂ (99.999%, 3–5 bar)
Power Supply230 V, 50/60 Hz, 5 A, 1100 W
Dimensions800 × 500 × 370 mm
Weight50 kg
DisplayIntegrated Touchscreen Interface
Leak DetectionAutomated Self-Test Routine
Operating ModesCapture-only, Purification-only, Integrated Capture-Purification
CalibrationISO Delta-compatible active calibration with electronic mass flow control
ComplianceDesigned for GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelPRI-8610
Instrument TypeMulti-parameter Portable Soil Respiration Analyzer
CO₂ Range0–2000 ppm (customizable)
H₂O Range0–6% v/v
CO₂ Accuracy±2% of reading (±1.5% after calibration)
H₂O Accuracy±2% of reading
CO₂ Zero Stability±2% over >12 months
Sample Flow Rate1 L/min (adjustable)
CO₂ Repeatability @ Zero±0.3%
CO₂ Repeatability @ Span±1.5%
Operating Pressure800–1150 mbar
Humidity Range<99% RH, non-condensing
CO₂ Zero Drift (Constant Temp)±2%/year
CO₂ Zero Drift (Ambient Temp Change)±0.03%/°C
Power Supply12 V Li-ion battery
Power Consumption<10 W (steady state)
T₉₀ Response Time10 s (configurable)
Battery Life8 hours per charge
Weight (Analyzer Unit)8 kg
Operating Temperature−20 to +45 °C
Dimensions (Analyzer)475 × 372 × 192 mm
Soil ChamberDiameter 220 mm, Height 120 mm, Volume 3718 cm³, Base Area 314 cm²
Air Pressure Sensor Range150–1150 mbar
Air Pressure Accuracy±2 mbar
Soil Temperature Range−20 to +85 °C
Soil Temperature Accuracy±0.2 °C
Soil Moisture Range0–100%
Soil Moisture Accuracy±3%
Dynamic Pressure CompensationYes (Patent ZL201420354126.4)
Integrated TabletYes
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGeoisochem CSIA
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelPRI-503
Detection PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
Measurable GasesCO₂, CH₄, H₂O
CO₂ Range Options0–0.2%, 0.5%, 1%, 5%, 10%, 100%
CH₄ Range Options0–5%, 10%, 30%
H₂O Range0–6%
CO₂/CH₄ Accuracy±2% (±1.5% after calibration)
Zero Stability (CO₂/CH₄)±2% over >12 months
Repeatability (Zero/Span)±0.3%/±1.5%
Zero Drift (Constant Temp.)±2%/year
Zero Drift (Ambient Temp.)±0.03%/°C
H₂O Accuracy±2%
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T90 Response Time10 s (adjustable)
Warm-up Time1 min
Humidity Limit<99% RH, non-condensing
OutputsRS-232, Analog (4–20 mA / 0–10 V)
Dimensions250 × 160 × 90 mm
Weight2.2 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMIRA ULTRA VOC
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelPRI-502
Detection PrincipleDual-Wavelength Non-Dispersive Infrared (Dual-NDIR)
Measurable GasesCH₄ (0–50,000 ppm), H₂O (0–6% vol)
Accuracy±2% FS (CH₄), ±2% FS (H₂O)
Zero Stability (CH₄)±2% FS over >12 months
Repeatability (CH₄)±0.3% FS at zero, ±1.5% FS at span
Temperature Drift (CH₄)±0.03% FS/°C (ambient), ±2% FS/year (thermostated)
Operating Temperature−20 to +45 °C
Operating Pressure800–1150 mbar
Sample Flow Rate1 L/min (adjustable)
T90 Response Time10 s (adjustable)
Warm-up Time1 min
Humidity Range<99% RH, non-condensing
Output InterfacesRS-232, analog (4–20 mA / 0–10 V)
Dimensions250 × 160 × 90 mm
Weight1.2 kg
Power Supply7–28 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMIRA ULTRA N2O CO
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
(brandPri-eco
originBeijing, China
manufacturerPri-eco
typebenchtop isotope ratio mass spectrometer
modelIsotope5 CNS
measurement rangeδ¹³C, δ¹⁵N, δ³⁴S, δ³²S
resolution>75 at m/z 29)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelPRI-8620
Instrument TypeMulti-gas Soil Respiration Analyzer
Power Consumption (Steady State)< 28 W
Power Supply12 V Lithium Battery
Dimensions475 × 372 × 192 mm
CO₂ Precision (5 min)0.6 ppm
CH₄ Precision (5 min)0.2 ppb
H₂O Precision (5 min)10 ppm
CO₂ Range0–2000 ppm
CH₄ Range0–500 ppm
H₂O Range0–3 %
Sample Flow Rate800 mL/min (adjustable)
Ambient Humidity Tolerance< 99 % RH (non-condensing)
Air Pressure Range (Chamber)150–1150 mbar
Air Pressure Accuracy±2 mbar
Chamber Diameter220 mm
Chamber Height120 mm
Chamber Volume3718 cm³
Soil Temperature Range−20 to +85 °C
Soil Temperature Accuracy±0.2 °C
Soil Moisture Range0–100 %
Soil Moisture Accuracy±3 %
Soil Collar Area314 cm²
Chamber Weight1.8 kg
System Weight13 kg
Dynamic Pressure CompensationYes (Patent No. ZL201420354126.4)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPRI-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelPRI-8160
Price RangeUSD 28,000 – 70,000
Chamber MaterialTransparent Aluminum Alloy / Opaque Acrylic
External Dimensions44 × 26 × 26 cm (L×W×H)
Chamber Diameter20 cm
Chamber Height13 cm (adjustable)
Measurement Volume4000 cm³ (customizable)
Measurement Area315 cm² (customizable)
Operating PrincipleDynamic Pressure-Balanced Flow-Through System
ActuationStepper Motor
Control UnitEmbedded Microcontroller
InterfaceAviation Connector
Remote OperationBluetooth/WiFi-enabled Mobile App (iOS/Android)
IP RatingIP65
Weight5.0 kg (including handle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelZERO Mobile-Mounted
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Detectable Gases & RangesCH₄ (0–10,000 ppm), C₂H₆ (0–1,000 ppm), H₂O (0–3 %)
Accuracy (1 s)CH₄: 1 ppb, C₂H₆: 0.5 ppb, H₂O: 50 ppm
Data Update Rate1–5 Hz
Sample Flow Rate~330 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99 % RH (non-condensing)
PositioningHigh-Accuracy BeiDou GNSS + Wind Correction
Power ConsumptionAnalyzer: 20–40 W
Full System (incl. pump)≤80 W
Weight8.3 kg
Dimensions450 × 350 × 150 mm
Data Storage256 GB–2 TB onboard + unlimited cloud archive
Communication InterfacesWi-Fi, 5G, RS-232, Ethernet
Leak Localization Accuracy<1 m
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelPSL8 MODBUS
PriceUpon Request
Operating Voltage6–16 VDC
Current Consumption13–20 mA (active), 400 µA (standby)
Operating Temperature Range−40 to +80 °C
Square Wave Input Frequency Range1 Hz – 35 kHz
Low-Frequency AC Input Sensitivity20 mV RMS (min. for 1–20 Hz), 200 mV RMS (min. for 0.5–200 Hz), 2000 mV RMS (min. for 0.3–10 kHz), 5000 mV RMS (min. for 0.3–20 kHz)
Output SignalModbus RTU over RS-485 (2-wire or 4-wire)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelPRI-5231
PriceUpon Request
Application FieldEnvironmental Monitoring
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured Gases and RangesCO₂ (0–3500 ppm), N₂O (0–500 ppb), H₂O (0–3 %v/v)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelAirScan 2000
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS) coupled with Single-Photon Avalanche Diode (SPAD) detection and 3D scanning lidar architecture
Detection ScopeOGMP 2.0 Tier 4 & Tier 5 compliant site-level continuous monitoring and component-level leak localization
Measurement Range360° panoramic field-of-regard, up to 200 m detection distance
Limit of Detection≥90% Probability of Detection (PoD) under representative atmospheric conditions
Quantification Accuracy±2× uncertainty (1-sigma) dependent on wind speed and direction
False Positive Rate0% when using factory-validated data processing algorithms and recommended client configuration
Laser Safety ClassClass 1M
Operating Temperature–40 °C to +50 °C
IP RatingIP67
Dimensions43 × 18 × 18 cm
Weight8 kg (including pan-tilt mount)
Power Supply24 VDC, 30 W
Communication InterfacesEthernet, Wi-Fi, mobile API endpoint
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginChina
ModelPRI-8630
Instrument TypeMulti-Gas Soil Respiration Analyzer
Power Consumption (Steady State)<28 W
Power Supply12 V Rechargeable Lithium Battery
Dimensions475 × 372 × 192 mm
Weight (Analyzer Unit)13 kg
Soil Chamber Weight1.8 kg
Chamber Diameter220 mm
Chamber Height120 mm
Chamber Volume3718 cm³
Soil Collar Area314 cm²
CO₂ Accuracy (5 min)±0.04 ppm (0–3500 ppm)
N₂O Accuracy (5 min)±0.03 ppb (0–500 ppb)
H₂O Accuracy (5 min)±10 ppm (0–3 %v/v)
Sampling Rate1 Hz
Sample Flow Rate800 mL/min (adjustable)
Air Pressure Range150–1150 mbar
Air Pressure Accuracy±2 mbar
Soil Temperature Range−20 to +85 °C
Soil Temperature Accuracy±0.2 °C
Soil Moisture Range0–100 %
Soil Moisture Accuracy±3 %
Relative Humidity Tolerance<99 % RH (non-condensing)
Dynamic Pressure CompensationYes (Patent ZL201420354126.4)
Detection PrincipleMid-Infrared Laser Absorption Spectroscopy (MIRLAS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginChina
ModelPRI-3000
Price RangeUSD 42,000–70,000
Vacuum Channels15
Ultimate Vacuum Pressure2 Pa
Pressure Measurement Range1–1000 Pa (Resolution: 0.1 Pa)
Heating Temperature RangeAmbient to 150 °C
Cryogenic CoolingIntegrated Compressor-Based System, Down to −100 °C
Sample Tube Volume5–15 mL
System Leak Rate≤1 Pa/min
Vacuum Pump Flow Rate5 L/s
Extraction ThroughputUp to 120 Samples/Day
Extraction Efficiency>98%
Water Recovery Rate98–100%
Dimensions (W×D×H)100 × 60 × 95 cm
Sample Tube InterfaceFlanged Borosilicate Glass Assembly
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
ManufacturerYes
Country of OriginChina
ModelPRI-8350
CO₂ Range0–5%
CO₂ PrecisionBetter than 80 ppb or 0.01% of full scale
δ¹³C Precision<0.3‰ (1σ) @ 1 s
H₂O Range0–100% RH
Sampling Frequency4 Hz (high-speed mode), 1 Hz (standard mode)
Response Time (10–90% / 90–10%)15 mL/min (fast), 5 mL/min (standard), down to 0.5 mL/min (ultra-low flow)
Number of Subsurface ChannelsStandard 6-channel
Calibration ChannelsOptional 3-channel configuration, customizable
Sampling Temperature–20 to +45 °C
Sampling Flow Rate1 mL/min at 760 Torr, filter-free operation
Sampling Pressure300–1000 Torr (40–133 kPa)
Operating Temperature–20 to +45 °C (extended range: –30 to +45 °C)
Power Consumption150 W
Input Voltage/Frequency110–220 VAC, 50–60 Hz
Dimensions (Host)483 mm (W) × 800 mm (D) × 476 mm (H)
Weight (Host)25 kg
Multiplexer UnitSame footprint, 20 kg
Diffusion ProbeStandard single-channel 3 × 1 m (length × depth), customizable
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelZERO Aerial Edition
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Target Gases & RangesCH₄ (0–10,000 ppm), C₂H₆ (0–1,000 ppm), H₂O (0–3 %v/v)
Sensitivity (1-s)CH₄: 1 ppb, C₂H₆: 0.5 ppb, H₂O: 50 ppm
Measurement Update Rate1–5 Hz
Sample Flow Rate~330 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity Limit<99% RH (non-condensing)
Power Supply12–15 V DC
Analyzer Power Consumption20–40 W
UAV Integration Power DrawUp to 500 W
PositioningHigh-Accuracy BeiDou GNSS + Wind Compensation Algorithm
Leak Localization Accuracy<1 m (typical)
Data OutputRS-232, Ethernet
Onboard Storage32 GB
Battery Autonomy≥1.5 h (standalone operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelPRI-5233
Detection PrincipleMid-Infrared Laser Direct Absorption Spectroscopy (MIRLAS)
Measured GasesCH₄ (0–500 ppm), C₂H₆ (0–500 ppm), H₂O (0–3 %v/v)
Precision (1 s)1 ppb CH₄, 0.5 ppb C₂H₆, 50 ppm H₂O
Precision (1 min)0.3 ppb CH₄, 0.10 ppb C₂H₆, 40 ppm H₂O
Precision (5 min)0.2 ppb CH₄, 0.08 ppb C₂H₆, 10 ppm H₂O
Sampling Flow Rate~180 mL/min
Operating Temperature–10 to +45 °C
Relative Humidity Limit<99% RH, non-condensing
Data OutputUSB, RS-232
Power Supply110–230 V AC
Power Consumption50 W (steady-state), 90 W (warm-up)
Weight10.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMGA-5
PricingUpon Request
Measurement PrincipleTime-Multiplexed Intermittent Continuous-Wave Quantum Cascade Laser Absorption Spectroscopy (TM-ICW-QCL)
Sampling Frequency1 Hz
Detection Limits (1 s)CO: 0.4 ppb, CO₂: 0.8 ppm, CH₄: 1 ppb, N₂O: 0.5 ppb, H₂O: 40 ppm
Detection Limits (200 s)CO: 0.07 ppb, CO₂: 0.08 ppm, CH₄: 0.2 ppb, N₂O: 0.1 ppb, H₂O: 6 ppm
Measurement RangesCO: 0–20 ppm, CO₂: 0–8000 ppm, CH₄: 0–200 ppm, N₂O: 0–20 ppm, H₂O: 0–10 %v/v
Maximum Drift (12 h)CO: 1 ppb, CO₂: 1 ppm, CH₄: 5 ppb, N₂O: 2 ppb, H₂O: 120 ppm
Operating Temperature–10 to +45 °C
Relative Humidity< 90 % RH (non-condensing)
Pressure Range700–1050 mbar
Sample Flow Rate0.5–1.5 L/min (high-flow option available)
Power Supply220 VAC, 50 Hz, < 450 W
Dimensions (Analyzer)48 W × 18 H × 62 D cm
Weight (Analyzer)20 kg
(Cooling Unit)11 kg
(Vacuum Pump)9 kg
Safety CertificationsCE-marked per IEC 61010-1:2010, IEC 61326-1:2012, IEC 60825:2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelRespirometer 3024B
Measurement PrinciplePolarographic Oxygen Consumption
Oxygen Range0–25 %
Temperature Range0–100 °C
Airflow Rate10–500 L/h
Oxygen Resolution0.1 %
Temperature Resolution0.1 °C
Flow Resolution0.1 L/h
Oxygen Accuracy±0.3 % of reading
Temperature Accuracy±0.5 °C
Flow Accuracy±1 % of full scale
Dimensions900 × 750 × 1000 mm
Weight27 kg
Power Supply230 V~50 Hz, Max. 2 A
ConnectivityEthernet (RJ45, Cat.5)
Gas SupplyHigh-purity compressed air (3 bar)
SoftwareRespi On Line (embedded), Respi Off Line (data analysis & export to TXT/XLS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPri-eco
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product TypePortable
Measurement PrincipleMid-Infrared Laser Absorption Spectroscopy (MIRLAS)
RepeatabilityCH₄ ≤ 0.3 ppb (1 min), C₂H₆ ≤ 0.10 ppb (1 min), H₂O ≤ 40 ppm (1 min)
Accuracy (1 s)CH₄ 1 ppb, C₂H₆ 0.5 ppb, H₂O 50 ppm
Accuracy RangeCH₄ 0–500 ppm, C₂H₆ 0–500 ppm, H₂O 0–3 %v/v
Sampling Flow Rate~180 mL/min
Operating Temperature−10 to +45 °C
Relative Humidity<99% RH, non-condensing
Data OutputUSB, RS-232
Power Supply110–230 V AC
Power Consumption50 W (steady-state), 90 W (warm-up)
Weight10.5 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0