Empowering Scientific Discovery

Beijing Purkinje General Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelG5
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient +7°C to 400°C
Max. Number of Simultaneous Inlet/Detector Mounts3
Temperature Program Steps10-step
Inlet/Detector Configuration FlexibilityModular
Carrier Gas ControlDigital Precision Flow/Pressure Regulation
ComplianceDesigned to meet core requirements of ISO/IEC 17025, ASTM D3606, USP <621>, and FDA 21 CFR Part 11 for data integrity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Analytical Chemistry
Maximum Column Oven Ramp Rate0–120 °C/min
Simultaneous Inlet ConfigurationUp to 3 Independent Inlets
Compatible DetectorsTCD, FID, ECD, FPD, NPD, PDD, MSD
Flow Control SystemPrecision Smart Flow Control (SFC)
Inlet Temperature CapabilityNot Specified
Pressure & Flow RangesNot Specified
Cooling RateNot Specified
Cloud-Enabled FeaturesMethod Optimization Engine, Remote Fault Diagnostics, Centralized Method Library
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Gas Chromatograph
ModelG600
Temperature Control Range7 °C above ambient to 400 °C
Oven Ramp Rate0.1–40 °C/min (adjustable in 0.1 °C increments)
Maximum Injector Temperature450 °C
Injector ConfigurationUp to three independently configurable inlets
Column Oven CoolingForced-air active cooling
Detector OptionsFID, TCD, ECD, PID (field-selectable)
ComplianceGLP/GMP-ready software audit trail, 21 CFR Part 11–compatible data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPurkinje
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelGC1100
Temperature Control RangeAmbient +6°C to 399°C
Oven Ramp Rate0–30°C/min
Carrier Gas Flow Range0–1200 mL/min
Carrier Gas Pressure Range0–970 kPa
Injector Maximum Temperature200°C
Injector Pressure Setting Range0–970 kPa
Injector Total Flow Setting Range0–1200 mL/min
Column Oven Temperature Accuracy±0.1°C
Column Oven Temperature Gradient±1.5%
TCD Sensitivity≥4000 mV·mL/mg (n-hexadecane)
TCD Noise≤0.04 mV
TCD Baseline Drift≤0.2 mV/30 min
FID Detection Limit≤8×10⁻¹² g/s (n-hexadecane)
FID Noise≤0.02 mV
FID Baseline Drift≤0.2 mV/30 min
Dimensions (L×W×H)562×550×492.5 mm
Weight44 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-made)
ModelL820
Instrument TypeConventional HPLC System
Application ScopeGeneral-purpose analytical HPLC
Price RangeUSD 56,000 – 84,000 (FOB Beijing)
ComplianceGLP/GMP, FDA 21 CFR Part 11, Chinese Pharmacopoeia 2020 Edition, Chinese Veterinary Pharmacopoeia 2020 Edition
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0