BrandPersee
OriginBeijing, China
ManufacturerPersee General Instrument Co., Ltd.
ModelTAS-990
Instrument TypeDual-mode (Flame + Electrothermal Graphite Furnace)
MonochromatorConcave Grating
Optical SystemDouble-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionD₂ Lamp + Self-reversal Method
Wavelength Accuracy±0.25 nm
Baseline Stability (Static)±0.004 A / 30 min
RSD (Repeatability)≤1.0% (Flame, Cu), ≤3.0% (GFAAS, Cu)
Characteristic Concentration (Cu)<0.04 µg/mL per 1% absorption
Detection Limit (Flame, Cu)<0.006 µg/mL
Detection Limit (GFAAS, Cd)<1.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorConcave Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal Method
Wavelength Accuracy±0.25 nm
Spectral Bandwidth≤0.15 nm
Detection Limit (Flame, Cu)0.006 µg/mL
Detection Limit (GFAAS, Cd)1.0 pg
Characteristic Concentration (Cu)<0.04 µg/mL per 1% absorption
Baseline Stability (Static)±0.004 A/30 min
RSD (Flame Cu)<1%
RSD (GFAAS Cu)<3.0%
RSD (GFAAS Cd)<4.0%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelCPG2/CPG2S
Instrument TypeGraphite Furnace Atomic Absorption Spectrometer (GFAAS)
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorSolid-State Detector
Background CorrectionAutomatic Deuterium/Hollow Cathode Lamp Dual-Beam Background Correction
Detection LimitsPb: 0.02 mg/kg, Cd: 0.002 mg/kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionZeeman Effect
Cu Sensitivity>0.3 A at 5 ppm
Precision (RSD)<0.4%
Cu Detection Limit<0.004 µg/mL
Baseline Drift<0.0008 A/30 min
Peak-to-Peak Baseline Noise<0.0008 A/30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorConcave Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal
Wavelength Accuracy±0.15 nm
Baseline Stability±0.002 A/30 min (static)
RSD (Repeatability)≤0.6% for Cu (air-acetylene), ≤1.0% for Cu (LPG-air) and Ba (N₂O-acetylene), ≤2.0% for Cu and Cd (graphite furnace)
Characteristic ConcentrationCu < 0.02 µg/mL/1% (air-acetylene & LPG-air), Ba < 0.15 µg/mL/1% (N₂O-acetylene)
Detection LimitCu < 0.004 µg/mL (flame), Cd < 0.4 pg (graphite furnace)