Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelCU-502
PricingAvailable Upon Request
Measurement PrincipleAC-modulated Absorption Photometry (Dual-beam Reference LED Architecture)
Target AnalyteCu²⁺ in Acidic Sulfate Electrolytes
Measuring Range (Cu)0–20 g/L, 0–50 g/L, 0–80 g/L (user-selectable)
Measuring Range (CuSO₄)0–100 g/L, 0–200 g/L, 0–300 g/L (correlated)
Resolution0.1 g/L (Cu), 1 g/L (CuSO₄)
Repeatability±2% FS
Response Time≤5 s (t₉₀)
Operating Temperature−5 °C to +40 °C
Relative Humidity≤85% RH (non-condensing)
Power SupplyAC 85–240 V, 50/60 Hz
Output SignalIsolated 4–20 mA DC (HART-compatible loop)
EnclosureIP65-rated front panel, DIN 96×96 mm cutout
Dimensions (H×W×D)96 × 96 × 163 mm
Weight~1.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelNi-502
PricingAvailable Upon Request
Measurement PrincipleAbsorption Photometry (UV-Vis, 540–560 nm)
Detection RangeHigh Range: 0.0–199.9 g/L Ni
Low Range0.00–19.99 g/L Ni
Resolution0.1 g/L (high), 0.01 g/L (low)
Accuracy±2% FS
Operating Temp.0–40 °C, ≤85% RH
OutputIsolated 4–20 mA DC (3-range switchable: 0–50/100/200 g/L or 0–5/10/20 g/L)
Relay OutputsTwo SPDT dry contacts (AC 200 V, 1 A resistive load)
Power SupplyAC 85–240 V, 50/60 Hz
EnclosureIP65-rated panel-mount housing (96 × 96 × 163 mm, ~1.3 kg)
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPMT-2500
PricingAvailable Upon Request
Detection PrincipleLaser Light Scattering (90° scattering geometry)
Alarm IndicatorTri-color LED (Green/Yellow/Red) with stepwise activation based on PM2.5 concentration thresholds
Power Supply3× AA alkaline batteries (internal) or DC 5 V via included USB cable
Display4-digit 7-segment LED
Accuracy±15 µg/m³ (for concentrations <100 µg/m³), ±15% (for ≥100 µg/m³)
Response Time≤6 seconds (T90)
Operating Temperature−10 °C to +50 °C
Operating Humidity0–95% RH (non-condensing)
Power Consumption0.6 W (active), 0.1 W (standby)
Data LoggingUser-selectable intervals (1/5/10/30/60 min)
Dimensions81(W) × 40(H) × 141(D) mm
Weight≈345 g (including batteries and silicone rubber cover)
AccessoriesUSB cable (15 cm), AA batteries, protective silicone cover
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (PRC)
ModelLQ-5Z
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelRC-V2
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelCHL-5Z
PriceUpon Request
Measurement Range0.0–200 µg/L (fluorescence-intensity calibrated)
Resolution0.1 µg/L
Display3.5-digit LCD
Excitation Wavelength400–470 nm
Emission Wavelength600–700 nm
Repeatability±2% (under controlled conditions)
Operating Temperature5–35 °C (non-freezing, shielded from direct sunlight)
Protection RatingIP63-equivalent
Power SupplyDC 4.5 V (3 × AAA/LR03 batteries)
Auto Power-OffAfter 30 minutes of inactivity
Dimensions75 mm (W) × 38 mm (H) × 180 mm (D)
Weight~300 g
Standard AccessoriesInstrument body, alkaline batteries, instruction manual, warranty card, carrying case
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelRA-915J
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAtomtex
ModelAT2140 / AT2140A
TypePersonal Dose Rate & Dose Meter (γ-ray)
Dose Rate Range (AT2140)0.01 μSv/h – 10 mSv/h
Dose Rate Range (AT2140A)0.01 μSv/h – 100 mSv/h
Dose Range0.01 μSv – 9.99 Sv
Dose Measurement Range0.1 μSv – 1.99 Sv
Relative Measurement Error±15% max.
Calibration Accuracy±5% max.
Sensitivity to ¹³⁷Cs1.8 cps/(μSv·h⁻¹)
Energy Response Range50 keV – 3 MeV
Energy Dependence (vs. 662 keV ¹³⁷Cs)±30% (AT2140), ±25% (AT2140A)
Angular Dependence (±60°, ¹³⁷Cs/⁶⁰Co)±25%
(²⁴¹Am)±60%
Response Time (Dose Rate >1 �Sv/h): ≤10 s (AT2140), ≤5 s (AT2140A)
Operating Temperature−20°C to +50°C (AT2140), −30°C to +60°C (AT2140A)
Relative Humidity (non-condensing)≤95% at 35°C
IP RatingIP40
Drop Resistance1.0 m onto hard surface
Power Supply2 × AA batteries
Battery Life5,000 h (AT2140), 10,000 h (AT2140A)
Dimensions & Weight111 × 70 × 28 mm, 0.11 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
RegionDomestic (China)
ModelOLM30B
PricingAvailable Upon Request
Flow Resolution0.01 L/min
Repeatability±1% FS
Maximum Flow Rate0–2 L/min
Power Supply110/220 V AC, 50/60 Hz
Power Consumption500 W
Operating Temperature Range–10 °C to +50 °C
WeightAir Pump Unit — 6.8 kg
ComplianceEPA Method 30B
Added to wishlistRemoved from wishlist 0
Add to compare
Brand
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelP-51
PricingUpon Request
Detection PrincipleColorimetric Gas Detection Tube Method
ComplianceDesigned to meet CDC-recommended field screening protocols for emergency response and occupational health assessments
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLQ-5Z-Multi
PricingAvailable Upon Request
Measurement PrincipleElectrode-Based (Grab Sampling)
Measurement RangeTMAH: 0.00–5.0% / 0.0–50.0 g/L
NaOH0.00–3.00% / 0.0–30.0 g/L
Na₂CO₃0.0–10.0% / 0–100 g/L
NH₃0.0–2.00% / 0.0–20.0 g/L
H₂SO₄0.0–2.00% / 0.0–20.0 g/L
HNO₃0.0–2.00% / 0.0–20.0 g/L
Sample Temperature0.0–40.0 °C
Accuracy±5% FS
CalibrationZero and Span Calibration
Temperature CompensationAutomatic
Enclosure RatingIP66
Power Supply3×AAA batteries with auto power-off
Electrode Type4C-type, 1 m standard cable
Dimensions (Instrument)75(W)×180(D)×38(H) mm
Electrode Dimensionsφ17×180(L) mm
Weight (Instrument)~300 g
Weight (Electrode)~50 g
Standard KitAnalyzer with batteries, 4C electrode, user manual, certificate of conformity
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelCU-5Z
PriceUpon Request
Measurement PrincipleAbsorption Photometry
Measurement Ranges0.000–1.200 mol/L (Cu²⁺ molar concentration)
Accuracy±2% FS (under specified calibration and environmental conditions)
Resolution0.001 mol/L
CalibrationTwo-point calibration using certified Cu²⁺ standard solutions
Temperature CompensationAutomatic (NTC sensor integrated in CUD-61 electrode)
Display3½-digit LCD
Operating Environment−5°C to +45°C, ≤85% RH (non-condensing)
Power SupplyDC 4.5 V (3 × AA alkaline batteries), auto-power-off after 30 min idle
Dimensions (main unit)75(W) × 180(D) × 38(H) mm
Weight~300 g (main unit), ~550 g (CUD-61 electrode with 2 m cable)
Standard ConfigurationMain unit, CUD-61 copper-selective electrode (2 m coaxial cable), instruction manual, certificate of conformity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAP Buck
ModelLP-20
Flow Range5–20 L/min (constant-flow mode)
Accuracy±5% of setpoint (at <5 L/min, with APB-109030 controller)
Max Backpressure60" H₂O (15 kPa)
PowerRechargeable NiCd battery pack (4.8 V, 1.0 Ah)
Operating Temperature0–40 °C
Dimensions11.4 × 10.2 × 5.0 cm (H × W × D)
Weight879 g
Inlet Port3/8" OD / 1/4" ID
DisplayEZ-Backlit™ LCD with multilingual UI (English, Spanish, French)
Data LoggingBuilt-in sampling time, flow rate, and total volume tracking
ComplianceDesigned for OSHA, NIOSH, and ISO 17025-aligned field sampling workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAFRISO
ModelE30X
TypePortable Flue Gas Analyzer
Sensor TechnologyElectrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, etc.)
Display4.3" TFT Color Screen with Chinese/English UI
Data StorageMicroSD card (up to 16 GB)
Battery LifeUp to 12 h (Li-ion, rechargeable during operation)
Auto-CalibrationBuilt-in zero and span check
Response Time<20 s (T90)
AccuracyCO measurement ±2 ppm (low-range), NOₗₒw ≤2 ppm error
ComplianceEN 50379-1/-2, DIN EN 15545, CE marked
ConnectivityBluetooth 4.2, USB-C, QR code export
Operating Temperature0–40 °C
Dimensions230 × 120 × 65 mm
Weight1.2 kg
Magnetic MountIntegrated rear magnet for hands-free mounting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAFRISO
OriginGermany (Manufactured under German engineering standards, assembled/quality-controlled in Beijing)
Manufacturer TypeOEM/ODM Producer
ModelM60X
ComplianceEN 50379-1/-2, TÜV-certified
Sensor Lifespan≥5 years (O₂, CO/H₂, SO₂low, NO, NO₂, NOₓ)
Response time (T90)O₂ <20 s
O₂ range0–21 vol.% (±0.2 vol.%)
CO (H₂-compensated)0–20,000 ppm (±5 ppm up to 50 ppm, ±5% of reading above)
COhigh0–4.0 vol.% (40,000 ppm)
SO₂0–5,000 ppm
NO0–5,000 ppm
NO₂0–500 ppm
NOₓ (calculated)0–5,500 ppm
CO₂ (NDIR)0–max theoretical (fuel-dependent)
Flue gas temperature0–1000 °C (±1 °C up to 300 °C, ±1% above)
Ambient temperature−20–+200 °C
Differential pressure±150 hPa
Flow velocity0.5–70 m/s
Display3.5″ TFT color (240 × 320 px)
Data loggingInternal + optional microSD/SDHC (up to 32 GB)
BatteryLi-ion 3.6 V / 2900 mAh (≥12 h operation, chargeable during measurement)
Dimensions220 × 90 × 53 mm (incl. magnetic protective sleeve)
Weight~685 g
EnclosureIP42 (EN 60529)
InterfaceIR, Bluetooth 4.2, USB Mini-B
Accessories290 mm 600 °C probe, 2.4 m heated sampling hose, dual-stage KFP condensate filter with integrated thermocouple, ambient temp probe, magnetic sleeve, carry case, charger/USB cable, EN 50379 certificate, factory calibration certificate, user manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
OriginBeijing, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelV100
PricingAvailable Upon Request
Flow Rates28.3 L/min, 50 L/min, 100 L/min
DisplayColor LCD with Touch Interface
Data Storage>500 Sampling Records
ConnectivityEthernet & USB
Weight12 lbs (5.4 kg)
Dimensions10″ L × 8″ W × 7″ H (254 × 203 × 178 mm)
Power Supply100–240 V AC, 50/60 Hz
Exhaust Filter0.2 µm Sterile Vent Filter
Housing & Sampling Heads316 Stainless Steel + Microban®-Impregnated Kydex®
Sampling MethodsAndersen-style Impaction & Rotary Slit™ Impaction
Sampling Head OptionsR2S (Rotary Slit Standard), RCG (Compressed Gas), RAS (Remote Access Sampling)
Remote ControlIR-enabled (Start/Stop/Pause/Resume)
CalibrationOn-screen Test Plate Verification
Sampling Duration per Cycle0–120 min
Programmable ParametersDelay Time, Start Time, Sample Duration, Number of Cycles, Inter-Cycle Pause
Print OutputThermal Label + Direct Thermal Paper
Sampling Capacity>300 Agar Plates per Full Memory Cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelGE Auto SDI
Price RangeUSD 2,800 – 7,000
SDI(15 min) Range0–6.7 SDI units
Fouling Factor Range1–100%
Power Supply110–120 VAC, 60 Hz or 220–230 VAC, 50 Hz
Inlet Connection1/4" OD quick-connect fitting
Flow Rate0.8 gpm (3.0 L/min)
Inlet Pressure65–100 psi (4.5–6.9 bar)
Dimensions (H×L×W)6×14×10 in (15×36×26 cm)
Weight8.0 lb (3.6 kg)
DisplayLCD with button interface
Membrane ReplacementOn-site, tool-free
Flow CalibrationBuilt-in flow standard
Data RetentionPersistent display until manual reset
Repeatability±0.2 SDI units
Acoustic AlertAudible alarm with silent mode option
EnclosureRugged portable case
ComplianceASTM D4189-07
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
Model3000-0C
Detection PrincipleCondensation Particle Counter (CPC)
Particle Size Range0.02–1.0 µm
Concentration Range0–100,000 particles/cm³
Sample Flow Rate100 cm³/min
Total Flow Rate700 cm³/min
Fit Factor CalculationDirect Cout/Cin Ratio
Challenge AgentIsopropanol (≥99.5%) or Ethanol
Display7-inch True Color Touchscreen
Operating Temperature10–35 °C
Relative Humidity20–85% RH (non-condensing)
Power SupplyAC 110–240 V, 50/60 Hz
Dimensions208 × 117 × 262 mm (W×H×D)
Weight2.3 kg
Compliance StandardsOSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016
ConnectivityUSB, Ethernet, Wi-Fi
Software CompatibilityWindows 7/8/10, .NET Framework 3.5
Data Export FormatMicrosoft Excel
Storage MediaUSB flash drive
Language OptionsEnglish, Chinese, Japanese, French, Spanish, Portuguese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Origin CategoryDomestic (China)
ModelK55
PricingAvailable Upon Request
Detector Resolution320 × 240 pixels
Thermal Sensitivity (NETD)≤30 mK
Display4-inch LCD, 320 × 240 resolution
Frame Rate60 Hz
Spectral Range7.5–13 µm
Temperature Range–20 °C to +650 °C
Operating Temperature–20 °C to +85 °C (15 min at +150 °C
IP RatingIP67
Weight1.1 kg (with battery)
Dimensions<120 × 125 × 280 mm
Battery Life4 hours continuous operation
Video FormatMPEG-4
Internal StorageUp to 200 video files, total recording time up to 600 minutes, max clip length 5 minutes
Digital Zoom
Wake-up Time from Sleep Mode<4 s
Startup Time<17 s
ChargingDual-bay desktop charger
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelFI-47
Membrane Diameter47 mm
Membrane Pore Size0.45 µm (Mixed Cellulose Ester)
Operating Pressure207 ± 7 kPa
Sample Volume500 mL per measurement
Temperature Stability Requirement±1 °C during test duration
Inlet ConnectionDN15
Included Consumables25 pcs of 47 mm × 0.45 µm MCE membranes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
ModelSDW-6008
Measurement Range0–100 g/L (Suspended Solids)
Temperature Range0–50.0 °C
Resolution0.01 mg/L / 0.01 g/L (SS), 0.1 °C (Temp)
Accuracy±1% F.S. (SS), ±0.3 °C (Temp)
OutputDual 4–20 mA (≤750 Ω), RS485 MODBUS RTU
Relay Outputs2 × SPDT, 3 A @ 250 VAC / 30 VDC
Power Supply85–265 VAC ±10%, 50 ±1 Hz or 9–36 VDC
Enclosure RatingIP65
Dimensions98 × 98 × 130 mm
MountingPanel or Wall
Weight0.6 kg
Operating Environment−10 to +60 °C, ≤90% RH, non-condensing
Sensor CompatibilityCS7860D Digital Turbidity/Suspended Solids Sensor (IP68, G3/4 thread, 0.01–50,000 mg/L, ±5% or ±0.5 NTU, 0–45 °C, 12 VDC, RS485 MODBUS RTU)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
ModelZLFI00001
Membrane Diameter47 mm
Membrane Pore Size0.45 µm
Test Pressure2.0–2.2 bar (29–32 psi)
SDI Calculation Interval0–5–15 min
ComplianceASTM D4189-95
IncludesPressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes
Accessories Required500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
ModelinnoCon 6800T
Measurement Principle90° Light Scattering (EN ISO 7027 Compliant)
Turbidity Range0.0–1000.0 NTU
SS Range0.0–2000.0 mg/L (or 0.0–30.0 g/L with innoSens 810S sensor)
Resolution0.1 NTU / 0.1 mg/L / 0.1 g/L
Accuracy±2% f.s. (NTU/SS), ±3% f.s. (g/L)
OutputDual 4–20 mA (meas. value & temp.), RS485 Modbus RTU
DisplayDot-matrix, bilingual (English/Chinese)
Enclosure RatingIP65 (controller), IP68 (sensor)
Power Supply90–260 VAC, 50/60 Hz
Operating Temp.–10 to +60 °C (controller), 0 to +60 °C (sensor)
Sensor Material316L stainless steel housing, custom optical glass
Pressure Rating4 bar
Cable Length10 m standard
MountingWall-mount controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandStarwood
OriginBeijing, China
Manufacturer TypeManufacturer
ModelRizonSDI
Operating Temperature0–65 °C
Operating Humidity≤90% RH
Sample Flow Rate>2 L/min
Test Pressure Range0.3–0.5 MPa
Dimensions365 mm × 270 mm × 150 mm
Weight4.5 kg
Housing MaterialReinforced Engineering Plastic
Inlet Connection5/16″ Quick-Connect Fitting
Inlet Tubing OD5/16″
Inlet Temperature Range−5–40 °C (non-freezing)
Battery Capacity4400 mAh
Operating VoltageDC 12 V
Continuous Operation TimeUp to 25 h
Charging Time6 h
Data Storage100 test records with timestamp (real-time clock)
SDI CalculationSDI₅, SDI₁₀, SDI₁₅ per ASTM D4189-07
Optional AccessoriesDiaphragm Booster Pump (DC 24 V, 5 A, max. 0.7 MPa, 4 L/min), 47 mm MCE Membranes (0.45 µm)