| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CU-502 |
| Pricing | Available Upon Request |
| Measurement Principle | AC-modulated Absorption Photometry (Dual-beam Reference LED Architecture) |
| Target Analyte | Cu²⁺ in Acidic Sulfate Electrolytes |
| Measuring Range (Cu) | 0–20 g/L, 0–50 g/L, 0–80 g/L (user-selectable) |
| Measuring Range (CuSO₄) | 0–100 g/L, 0–200 g/L, 0–300 g/L (correlated) |
| Resolution | 0.1 g/L (Cu), 1 g/L (CuSO₄) |
| Repeatability | ±2% FS |
| Response Time | ≤5 s (t₉₀) |
| Operating Temperature | −5 °C to +40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Output Signal | Isolated 4–20 mA DC (HART-compatible loop) |
| Enclosure | IP65-rated front panel, DIN 96×96 mm cutout |
| Dimensions (H×W×D) | 96 × 96 × 163 mm |
| Weight | ~1.3 kg |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Ni-502 |
| Pricing | Available Upon Request |
| Measurement Principle | Absorption Photometry (UV-Vis, 540–560 nm) |
| Detection Range | High Range: 0.0–199.9 g/L Ni |
| Low Range | 0.00–19.99 g/L Ni |
| Resolution | 0.1 g/L (high), 0.01 g/L (low) |
| Accuracy | ±2% FS |
| Operating Temp. | 0–40 °C, ≤85% RH |
| Output | Isolated 4–20 mA DC (3-range switchable: 0–50/100/200 g/L or 0–5/10/20 g/L) |
| Relay Outputs | Two SPDT dry contacts (AC 200 V, 1 A resistive load) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Enclosure | IP65-rated panel-mount housing (96 × 96 × 163 mm, ~1.3 kg) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RC-V2 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CHL-5Z |
| Price | Upon Request |
| Measurement Range | 0.0–200 µg/L (fluorescence-intensity calibrated) |
| Resolution | 0.1 µg/L |
| Display | 3.5-digit LCD |
| Excitation Wavelength | 400–470 nm |
| Emission Wavelength | 600–700 nm |
| Repeatability | ±2% (under controlled conditions) |
| Operating Temperature | 5–35 °C (non-freezing, shielded from direct sunlight) |
| Protection Rating | IP63-equivalent |
| Power Supply | DC 4.5 V (3 × AAA/LR03 batteries) |
| Auto Power-Off | After 30 minutes of inactivity |
| Dimensions | 75 mm (W) × 38 mm (H) × 180 mm (D) |
| Weight | ~300 g |
| Standard Accessories | Instrument body, alkaline batteries, instruction manual, warranty card, carrying case |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CU-5Z |
| Price | Upon Request |
| Measurement Principle | Absorption Photometry |
| Measurement Ranges | 0.000–1.200 mol/L (Cu²⁺ molar concentration) |
| Accuracy | ±2% FS (under specified calibration and environmental conditions) |
| Resolution | 0.001 mol/L |
| Calibration | Two-point calibration using certified Cu²⁺ standard solutions |
| Temperature Compensation | Automatic (NTC sensor integrated in CUD-61 electrode) |
| Display | 3½-digit LCD |
| Operating Environment | −5°C to +45°C, ≤85% RH (non-condensing) |
| Power Supply | DC 4.5 V (3 × AA alkaline batteries), auto-power-off after 30 min idle |
| Dimensions (main unit) | 75(W) × 180(D) × 38(H) mm |
| Weight | ~300 g (main unit), ~550 g (CUD-61 electrode with 2 m cable) |
| Standard Configuration | Main unit, CUD-61 copper-selective electrode (2 m coaxial cable), instruction manual, certificate of conformity |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GE Auto SDI |
| Price Range | USD 2,800 – 7,000 |
| SDI(15 min) Range | 0–6.7 SDI units |
| Fouling Factor Range | 1–100% |
| Power Supply | 110–120 VAC, 60 Hz or 220–230 VAC, 50 Hz |
| Inlet Connection | 1/4" OD quick-connect fitting |
| Flow Rate | 0.8 gpm (3.0 L/min) |
| Inlet Pressure | 65–100 psi (4.5–6.9 bar) |
| Dimensions (H×L×W) | 6×14×10 in (15×36×26 cm) |
| Weight | 8.0 lb (3.6 kg) |
| Display | LCD with button interface |
| Membrane Replacement | On-site, tool-free |
| Flow Calibration | Built-in flow standard |
| Data Retention | Persistent display until manual reset |
| Repeatability | ±0.2 SDI units |
| Acoustic Alert | Audible alarm with silent mode option |
| Enclosure | Rugged portable case |
| Compliance | ASTM D4189-07 |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FI-47 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm (Mixed Cellulose Ester) |
| Operating Pressure | 207 ± 7 kPa |
| Sample Volume | 500 mL per measurement |
| Temperature Stability Requirement | ±1 °C during test duration |
| Inlet Connection | DN15 |
| Included Consumables | 25 pcs of 47 mm × 0.45 µm MCE membranes |
| Brand | Starwood |
|---|---|
| Model | SDW-6008 |
| Measurement Range | 0–100 g/L (Suspended Solids) |
| Temperature Range | 0–50.0 °C |
| Resolution | 0.01 mg/L / 0.01 g/L (SS), 0.1 °C (Temp) |
| Accuracy | ±1% F.S. (SS), ±0.3 °C (Temp) |
| Output | Dual 4–20 mA (≤750 Ω), RS485 MODBUS RTU |
| Relay Outputs | 2 × SPDT, 3 A @ 250 VAC / 30 VDC |
| Power Supply | 85–265 VAC ±10%, 50 ±1 Hz or 9–36 VDC |
| Enclosure Rating | IP65 |
| Dimensions | 98 × 98 × 130 mm |
| Mounting | Panel or Wall |
| Weight | 0.6 kg |
| Operating Environment | −10 to +60 °C, ≤90% RH, non-condensing |
| Sensor Compatibility | CS7860D Digital Turbidity/Suspended Solids Sensor (IP68, G3/4 thread, 0.01–50,000 mg/L, ±5% or ±0.5 NTU, 0–45 °C, 12 VDC, RS485 MODBUS RTU) |
| Brand | Starwood |
|---|---|
| Model | ZLFI00001 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm |
| Test Pressure | 2.0–2.2 bar (29–32 psi) |
| SDI Calculation Interval | 0–5–15 min |
| Compliance | ASTM D4189-95 |
| Includes | Pressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes |
| Accessories Required | 500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution) |
| Brand | Starwood |
|---|---|
| Model | innoCon 6800T |
| Measurement Principle | 90° Light Scattering (EN ISO 7027 Compliant) |
| Turbidity Range | 0.0–1000.0 NTU |
| SS Range | 0.0–2000.0 mg/L (or 0.0–30.0 g/L with innoSens 810S sensor) |
| Resolution | 0.1 NTU / 0.1 mg/L / 0.1 g/L |
| Accuracy | ±2% f.s. (NTU/SS), ±3% f.s. (g/L) |
| Output | Dual 4–20 mA (meas. value & temp.), RS485 Modbus RTU |
| Display | Dot-matrix, bilingual (English/Chinese) |
| Enclosure Rating | IP65 (controller), IP68 (sensor) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Operating Temp. | –10 to +60 °C (controller), 0 to +60 °C (sensor) |
| Sensor Material | 316L stainless steel housing, custom optical glass |
| Pressure Rating | 4 bar |
| Cable Length | 10 m standard |
| Mounting | Wall-mount controller |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | RizonSDI |
| Operating Temperature | 0–65 °C |
| Operating Humidity | ≤90% RH |
| Sample Flow Rate | >2 L/min |
| Test Pressure Range | 0.3–0.5 MPa |
| Dimensions | 365 mm × 270 mm × 150 mm |
| Weight | 4.5 kg |
| Housing Material | Reinforced Engineering Plastic |
| Inlet Connection | 5/16″ Quick-Connect Fitting |
| Inlet Tubing OD | 5/16″ |
| Inlet Temperature Range | −5–40 °C (non-freezing) |
| Battery Capacity | 4400 mAh |
| Operating Voltage | DC 12 V |
| Continuous Operation Time | Up to 25 h |
| Charging Time | 6 h |
| Data Storage | 100 test records with timestamp (real-time clock) |
| SDI Calculation | SDI₅, SDI₁₀, SDI₁₅ per ASTM D4189-07 |
| Optional Accessories | Diaphragm Booster Pump (DC 24 V, 5 A, max. 0.7 MPa, 4 L/min), 47 mm MCE Membranes (0.45 µm) |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PolyPen-Aqua |
| Instrument Type | Algal Counter |
| Light Source | Pulsed Xenon Lamp (380–780 nm) |
| Spectral Range | 380–780 nm |
| Measurement Modes | Reflectance, Absorbance, Transmittance |
| Data Output | Spectral curves (Aλ), derived pigment indices, GPS-tagged georeferenced records |
| Software Interface | PolyPen Control & Analysis Suite (Windows/macOS) |
| Compliance | Designed for field-deployable GLP-aligned workflows |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | IM2021-1 |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| pH Range | 0.00–14.00 |
| mV Range | −1999.9 to +1999.9 mV |
| Detection Limit | 0.01 ppm (as F⁻) |
| Response Time | ≤2 s |
| pH Resolution | 0.01 |
| Temperature Operating Range | 5–40 °C |
| Power Supply | AC 220 V, 100 W |
| Brand | Starwood |
|---|---|
| Model | EZ-SDI-1-C |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 42,000 |
| Output Signal | 4–20 mA analog |
| Compliance Standard | ASTM D4189-95 |
| Display | 4×20 backlit LCD |
| Enclosure Rating | NEMA 4X |
| Filter Diameter | 25 mm |
| Test Durations | SDI₅, SDI₁₀, SDI₁₅ |
| Flow Rate | 1000 mL/min |
| Operating Pressure | 70–1500 psi |
| Power Supply | 240 VAC, 60 Hz |
| Communication Interface | RS-232 |
| Dimensions (H×W×D) | 279 × 381 × 229 mm |
| Weight | Not specified |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SDW-811 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Price Range | USD 1,400 – 2,800 |
| Measurement Principles | Absorption Spectrophotometry (Fixed-Wavelength, Single-Beam) |
| Target Analytes | Aniline, Volatile Phenols, Hydrazine, Bromide, Formaldehyde |
| Detection Range (Aniline) | 0.03–5.00 mg/L |
| Detection Range (Phenols) | 0.20–10.0 mg/L |
| Detection Range (Hydrazine) | 0.01–0.50 mg/L |
| Detection Range (Bromide) | 0.10–5.00 mg/L |
| Detection Range (Formaldehyde) | 0.05–2.50 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±5% FS |
| Repeatability | ±3% RSD |
| Optical Stability | ≤0.002 A / 20 min |
| Dimensions (L×W×H) | 266 × 220 × 130 mm (varies slightly by module) |
| Weight | <1.0 kg |
| Power Consumption | 30 W |
| Light Source | High-intensity, long-life (100,000 h) monochromatic cold LED |
| Filter System | Precision narrow-band interference filters |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | Internal non-volatile memory for calibration curves and measurement history |
| Microcontroller | 16-bit low-power MCU |
| Housing Material | Corrosion-resistant molded ABS |
Show next