Empowering Scientific Discovery

Beijing Wanlianda Xinke Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWandaida
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTS-XH4000-S
Price RangeUSD 14,000–42,000
Form FactorHandheld / Portable
Application TypeGeneral-Purpose
Elemental RangeNa (Z=11) to U (Z=92)
Concentration Range1 ppm – 99.99%
Energy Resolution<140 eV (at Mn Kα)
Repeatability±0.1% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelWLD-5000
Instrument TypeSequential Scanning ICP-OES
Detection LimitsZn 213.856 nm ≤ 0.003 µg/L, Mn 257.610 nm ≤ 0.002 µg/L
Precision (RSD)≤1.5%
Stability (RSD)≤2.0%
Wavelength Range190–500 nm (3600 lines/mm grating) or 190–800 nm (2400 lines/mm grating)
Optical Resolution≤0.008 nm (3600 L/mm), ≤0.015 nm (2400 L/mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
ModelCS-902G
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (2.5 kW Output Power)
Carbon Range0.00002–30% (expandable)
Sulfur Range0.00002–5% (expandable)
Sensitivity0.1 ppm
PrecisionCarbon RSD ≤ 0.5%, Sulfur RSD ≤ 1.5%
Analysis Time40 s
Detection SystemsDual-channel CO₂ and SO₂ infrared cells + CO-specific infrared cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelCS-902T
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Heating SystemHigh-Frequency Induction Furnace
Carbon Range0.00002–10% (extendable)
Sulfur Range0.00002–5% (extendable)
Sensitivity0.1 ppm
PrecisionC RSD ≤ 0.5%, S RSD ≤ 1.5%
Analysis Time40 s
Furnace Output Power2.5 kW
ComplianceGB/T 20123–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
ModelCS-300
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace
Carbon Range0.00002–10 wt%
Sulfur Range0.00002–5 wt%
Sensitivity0.1 ppm
Precision±1% RSD (C: ≤0.6%, S: ≤1.5%)
Analysis Time40 s
Furnace Output Power2.5 kW
ComplianceGB/T 20123–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
ModelCS-901K
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (2.5 kW Output Power)
Carbon RangeC1: 0.00002–0.5%, C2: 0.05–100%
Sulfur RangeS1: 0.00002–0.5%, S2: 0.1–60% (extendable to 100%)
Sensitivity0.1 ppm
PrecisionCarbon RSD ≤ 0.4%, Sulfur RSD ≤ 1.0%
Analysis Time40 s
ComplianceISO 9556 (Carbon), ISO 4935 (Sulfur)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWanlianda
OriginBeijing, China
ModelCS-901B
Measurement PrincipleInfrared Absorption Spectroscopy
Heating SystemHigh-Frequency Induction Furnace (2.5 kW Output Power)
Carbon RangeC₁: 0.00002–0.5%, C₂: 0.05–99.9%
Sulfur Range0.00002–5%
Sensitivity0.1 ppm
PrecisionCarbon RSD ≤ 0.4%, Sulfur RSD ≤ 1.0%
Analysis Time40 s
Detection SystemsFour independent IR channels for high-carbon, low-carbon, sulfur, and carbon monoxide quantification
Sample CompatibilityFerrous & non-ferrous metals, iron alloys, ores, coke, raw materials, slags, rare earth materials