Empowering Scientific Discovery

Beijing Yingsheng Hengtai Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelGDA-F
Weight2 kg
Sampling MethodAutomatic Continuous Sampling
Operating TemperatureAmbient (15–30 °C)
Detection Rangeppb to ppm
Target GasesCl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelSampling Kit
ComplianceDesigned to Support ASTM D6196, ISO 16017-1, USP <621>, EPA Method TO-17 & TO-15 Derivatives
Sample MatricesGaseous, Aerosol, Liquid (Aqueous/Organic), Solid (Soil/Sediment), Semi-solid, Biological, and Unknown Contaminants
Integrated Preparative FunctionsThermal Desorption, Liquid-Liquid Extraction, Headspace Equilibration, Solid-Phase Adsorption, Solvent Elution, Filtration, and Direct GC/MS Injection Compatibility
AccessoriesColor-Coded PTFE-Sealed Vials, Tenax/Composite/Desorption Cartridges (Blue/Black/Red), Certified Deuterated Internal Standards (D6-Benzene, D8-Toluene, D10-Xylenes, D8-Naphthalene, D10-Anthracene, D10-Pyrene), Eppendorf Varipette 4720 (10 mL) & Biomaster 4830 (5 µL), Swagelok Alu-Plexiglas Fittings
PackagingRuggedized Portable Case with Modular Trays and Visual Identification System (Color-Coded by Matrix & Method)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN3
Sensor Array10 metal oxide semiconductor (MOS) sensors
Sensor Volume1.8 mL
Operating Temperature110 °C (sensor tube)
Response Time<1 s
Measurement Cycle~60 s (20 s exposure + 40 s recovery)
Sampling Flow Rate10–400 mL/min (internally regulated)
Sampling SystemDual built-in pumps (sample + zero air)
Zero Air SourceActivated charcoal-filtered ambient air or zero-air generator
DisplayIntegrated LCD screen
InterfaceUSB and/or RS232
Digital I/OTTL & digital signal ports
Operating Ambient0–40 °C, 5–95% RH (non-condensing)
Power30 W, 110–230 V AC or optional 12 V DC
Weight2.3 kg
Dimensions255 × 190 × 92 mm
Safety ComplianceIEC 61010-1
Detection Limit0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene)
SoftwareWinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN)
OS CompatibilityWindows XP and later
Calibration StabilityAutomated drift compensation over 12 months
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelGDA-FR
Detection TechnologiesIMS, PID, MOS, EC
Sensor Channels8 independent parallel channels
Library Size>300 calibrated chemical signatures
Response Time<2 s (typical), ≤60 s (full quantification)
Detection RangeSub-ppb to ppm level depending on analyte
PowerRechargeable Li-ion battery, >8 h continuous operation
ComplianceCE, RoHS, ATEX Zone 2/22 (optional), IEC 61508 SIL2-ready architecture
Operating Temperature−10 °C to +50 °C
Ingress ProtectionIP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Instrument TypePortable
Detection PrincipleHybrid IMS/PID/MOS/EC Sensor Fusion
Core ConfigurationMulti-Channel VOC & Inorganic Gas Detector
Operating Temperature−30 °C to 50 °C
Relative Humidity Range5–95% RH (non-condensing)
Power SupplyRechargeable Li-ion Battery (30 W, 8 h runtime)
Weight4.2 kg
Sample IntroductionIntegrated Auto-Sampling Pump with Continuous Gas Flow
Cycle Time5 min
Response Time2–60 s
Detection Library>300 Pre-Calibrated Compounds (VOCs, Inorganic Gases, Electronic Specialty Gases), Expandable
Data InterfacesRS-232, Ethernet, Wireless Transmission
SoftwareWinMuser GDA Suite
Heating ModuleIntegrated IR Heater for Solid/Surface Residue Volatilization
Alarm LogicTemplate-Based Pattern Recognition with User-Configurable Thresholds
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN3.5
Instrument TypePortable
Detection PrincipleMulti-sensor array (Metal Oxide Semiconductor, Electrochemical, PID)
Sensor Array10 distinct MOS sensors
Software PlatformWinMuster v5.x
Data Analysis AlgorithmsPCA, LDA, DFA, K-NN (Euclidean & Mahalanobis), PLS
ComplianceDesigned for ISO 18562-3 (biocompatibility of gas pathways), ASTM E2147-22 (odor intensity measurement), GLP-compliant audit trail support
Operating Environment5–40 °C, 20–90% RH (non-condensing)
Sample IntroductionIntegrated auto-sampling pump with mass-flow-controlled inlet (0.1–1.0 L/min adjustable)
ConnectivityUSB 2.0, RS-232, optional Ethernet module for remote station integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN3-meteo
ComplianceEN 13725:2003
Detection PrincipleMetal Oxide Semiconductor (MOS) Sensor Array with Multivariate Pattern Recognition
Output UnitOdor Units per cubic meter (OU/m³)
Data TransmissionWi-Fi + Optional GSM/GPRS
Meteorological IntegrationIntegrated anemometer and wind vane
Operating ModeFully Automated, Unattended 24/7 Monitoring
Software AlgorithmsPCA, PLS, Mahalanobis Distance, Euclidean Distance
Sensor Configuration10-channel MOS sensor array
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelOlfosense
Instrument TypeOnline
Detection PrincipleHybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors)
Accuracy±1–2%
Flow Rate Range10–400 mL/min
Response Time<1 second
Operating Temperature−30°C to +100°C
Operating Humidity0–90% RH
Sensor Configuration4× MOS, 1× PID, 2–4× electrochemical sensors
Output ParametersH₂S, NH₃, TVOC concentrations, user-selectable odorant(s) (1–2), and dimensionless odor unit (OU) values
ConnectivityWiFi/GSM/GPRS/3G
Data IntegrationOpen API, Modbus TCP/RTU, MQTT
ComplianceDesigned for EN 13725-compliant odor assessment workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelM-IR
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Modelmeteo
ComplianceEN 13725
Output UnitOdor Units per cubic meter (OU/m³)
Sensor Array10 MOS (Metal Oxide Semiconductor) sensors
Data AcquisitionContinuous, 24/7
CommunicationWi-Fi + optional GSM/GPRS
Meteorological IntegrationIntegrated anemometer & wind vane
Software AlgorithmsPCA, PLS regression, Mahalanobis & Euclidean distance analysis
Calibration ReferenceEN 13725-compliant dynamic olfactometry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGDA-FR
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN3-meteo
Sensor Array10 MOS metal oxide sensors
Odor Unit QuantificationOU/m³ per EN 13725
Data LoggingIntegrated DCR computer (Mini-ITX, 40 GB HDD, 512 MB RAM, Windows XP)
ConnectivityWi-Fi + optional GSM/GPRS module for SMS alerts
Meteorological IntegrationCo-located anemometer and wind vane with real-time digital output
ComplianceEN 13725:2003 certified odor quantification methodology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Instrument TypeOnline
Detection PrincipleHybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors)
Accuracy±2% FS
Flow Rate Range10–400 mL/min
Response Time<1 s
Operating Temperature−30°C to +100°C
Operating Humidity0–90% RH
Sensor Configuration4× MOS, 1× PID, 2–4× electrochemical sensors
Output ParametersH₂S, NH₃, TVOC, user-selectable target odorants (1–2), and dimensionless odor unit (OU) concentration
Communication InterfacesWiFi, GSM, GPRS, 3G, Ethernet
Data ManagementCloud database, local LAN, or open-network deployment
Compliance ReadyDesigned for integration into GLP/GMP- and ISO 16000-compliant environmental monitoring workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN 3.5
Sensor Array10 metal oxide semiconductor (MOS) sensors
Sensor Volume1.8 mL
Operating Temperature110 °C (sensor tube)
Response Time< 1 s
Measurement Cycle~60 s (20 s exposure + 40 s recovery)
Sampling Flow Rate10–400 mL/min (integrated mass flow control)
Built-in Pumps2 (sample + zero air)
Zero Air SourceActivated charcoal-filtered ambient air or zero-air generator
DisplayIntegrated LCD panel
InterfaceUSB and/or RS232
Digital I/OTTL and digital signal ports
Operating Ambient0–40 °C, 5–95% RH (non-condensing)
Power30 W, 110–230 V AC or optional 12 V DC
Weight2.3 kg
Dimensions255 × 190 × 92 mm
Safety ComplianceIEC 61010-1
Detection Limits0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene)
Software PlatformWinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN)
Data IntegrityAudit-trail enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelMobile-IR
DesignIntegrated ATR-based Portable FTIR System
Spectral Range4000–600 cm⁻¹ (typical)
Spectral Resolution≤4 cm⁻¹ (user-selectable)
Library>14,000 reference spectra of hazardous, industrial, and environmental chemicals
ComplianceIP67-rated enclosure
Data InterfaceWi-Fi, USB, Bluetooth
Operating SystemEmbedded Linux with OPUS/Mentor software suite
DisplayHigh-brightness capacitive touchscreen (≥10.1″)
PowerRechargeable Li-ion battery (≥6 h continuous operation)
Weight<5.2 kg
Dimensions320 × 240 × 180 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelGDA-X
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0