| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BOD Sensor |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO)-Based Respirometric Method |
| Sensor Type | Mercury-Free Electronic Pressure Sensor |
| BOD Range Options | 90, 250, 600, and 1000 ppm |
| Data Logging | Automatic storage of up to 5 BOD values at 24-hour intervals |
| Display | Digital LCD readout |
| Durability | Industrial-grade sensor housing for long-term stability in lab environments |
| Compliance | Designed to support ISO 5815-1:2017 and APHA Standard Methods 5210B respirometric BOD protocols |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FOC225E / FOC225I |
| Internal Volume | 196 L |
| Temperature Range | 3–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Control System | Microprocessor-based PID control |
| Power Consumption | 350 W |
| Net Weight | 40 kg |
| PC Connectivity | Yes, with dedicated software for real-time logging, temperature curve plotting, and programmable cycle scheduling |
| Door Configuration | FOC225E — solid insulated door |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PG Series |
| Detection Principle | Electrochemical Sensors (H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃) + Optional PID for VOCs |
| Form Factor | Portable |
| Response Time | < 30 s (typical for electrochemical sensors) |
| Repeatability | ±2% FS (for calibrated target gases) |
| Communication Protocols | Modbus RTU/TCP, RS485, Bluetooth/Wi-Fi optional |
| Sensor Interface | Hot-swappable intelligent electrochemical & PID modules |
| Compliance | CE-marked |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ECO 8 / ECO 25 |
| Instrument Type | Laboratory Benchtop Digestion Unit |
| Measurement Principle | Closed-Tube Thermal Oxidation (Dichromate Reflux Method) |
| Wavelength for Photometric COD Readout | 610 ± 20 nm (requires compatible spectrophotometer) |
| COD Range | 10–5000 mg/L O₂ |
| Accuracy | ±0.5 mg/L (at low range), ±3% (full scale) |
| Repeatability | ±0.5% RSD |
| LOD | 0.1 mg/L |
| Digestion Time Programmable | 0–199 min or continuous mode |
| Batch Capacity | 8 or 25 samples simultaneously |
| Operating Temperatures | 70, 100, 120, 150, 160 °C (user-selectable, PID-controlled) |
| Safety Features | Transparent polycarbonate lid with overheat cut-off, auto-shutdown after cycle completion, thermal insulation housing |
| Optional Accessory | Alphanumeric tube extractor for ECO 25 |
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UAC Series |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH (single/dual), CO₂, Alkalinity, ORP, Free Available Chlorine (FAC), Conductivity / TDS, Temperature |
| Display | 7-inch Color Touchscreen |
| Input/Output Flexibility | Universal Sensor Inputs, Relay Outputs (Configurable), Timer Functions, Web-Based Remote Access |
| Compliance Support | Designed for GLP-aligned operational logging and configurable audit trails per ISO/IEC 17025-informed practices |
| Software Capability | Trend Logging, Onboard Calibration History, Firmware Upgradability |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FTC90 / FTC90E / FTC90I |
| Internal Volume | 64 L |
| Temperature Range (FTC90E & FTC90I) | 3–50 °C |
| Temperature Range (FTC90) | 20 °C fixed |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution (FTC90E/FTC90I) | 0.1 °C |
| Control System | Microprocessor-based PID control |
| Power Consumption | 150 W (FTC90), 250 W (FTC90E/FTC90I) |
| Net Weight | 24.5 kg (FTC90), 29 kg (FTC90E/FTC90I) |
| Door Type | Solid door (FTC90/FTC90E), Double-glazed observation door (FTC90I) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | ECO6, ECO8, ECO16, ECO25 |
| Power Supply | 220–240 V / 50–60 Hz or 110–130 V / 50–60 Hz |
| Temperature Control Accuracy | ±0.5 °C |
| Max Heating Temperature | ECO6 up to 200 °C |
| Sample Capacity | ECO6: 6 × 20 mL tubes |
| ECO8 | 8 × Ø16 mm + 1 × Ø22 mm tubes |
| ECO16 | 14 × Ø16 mm + 2 × Ø22 mm tubes |
| ECO25 | 25 × Ø16 mm tubes |
| Power Consumption | ECO6: 700 W |
| ECO8 | 140 W |
| ECO16 | 550 W |
| ECO25 | 400 W |
| Weight | ECO6: 5.6 kg (12.3 lb) |
| ECO8 | 2.0 kg (4.4 lb) |
| ECO16 | 3.8 kg (8.4 lb) |
| ECO25 | 3.6 kg (7.9 lb) |
| Dimensions (W × H × D) | ECO6: 198 × 132 × 319 mm (7.8 × 5.2 × 12.5 in) |
| ECO8 | 135 × 95 × 230 mm (5.3 × 3.7 × 9.0 in) |
| ECO16 | 168 × 110 × 269 mm (6.6 × 4.3 × 10.6 in) |
| ECO25 | 155 × 95 × 275 mm (6.1 × 3.7 × 10.8 in) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model Series | BOD6/20, BMS6/10 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO) Consumption Method |
| Sensor Technology | Mercury-Free Electronic Pressure Sensor |
| BOD Range Options | 90, 250, 600, 1000 ppm |
| Data Logging | Automatic storage of up to five BOD values at 24-hour intervals |
| Compliance | Designed for ISO 5815-1:2017 and ASTM D5210-92 (Standard Test Method for Determining Anaerobic Biodegradation of Organic Compounds in the Presence of Municipal Sewage) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MG Series |
| Pricing | Available Upon Request |
| Measurement Principle | Electrochemical Sensing (with optional PID for VOCs) |
| Configuration | Fixed-Installation Online Analyzer |
| Response Time | < 30 s (typical for electrochemical sensors) |
| Repeatability | ±2% FS for H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃ |
| Detectable Gases | H₂S, NH₃, CH₃SH, (CH₃)₂S, CH₃SSCH₃, CS₂, C₈H₈, (CH₃)₃N, NOₓ, O₃, SO₂, VOCs (via PID), and derived odor unit (OU) calculation per GB/T 14675–2023 and EN 13725:2022 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADU |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-F |
| Weight | 2 kg |
| Sampling Method | Automatic Continuous Sampling |
| Operating Temperature | Ambient (15–30 °C) |
| Detection Range | ppb to ppm |
| Target Gases | Cl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Sampling Kit |
| Compliance | Designed to Support ASTM D6196, ISO 16017-1, USP <621>, EPA Method TO-17 & TO-15 Derivatives |
| Sample Matrices | Gaseous, Aerosol, Liquid (Aqueous/Organic), Solid (Soil/Sediment), Semi-solid, Biological, and Unknown Contaminants |
| Integrated Preparative Functions | Thermal Desorption, Liquid-Liquid Extraction, Headspace Equilibration, Solid-Phase Adsorption, Solvent Elution, Filtration, and Direct GC/MS Injection Compatibility |
| Accessories | Color-Coded PTFE-Sealed Vials, Tenax/Composite/Desorption Cartridges (Blue/Black/Red), Certified Deuterated Internal Standards (D6-Benzene, D8-Toluene, D10-Xylenes, D8-Naphthalene, D10-Anthracene, D10-Pyrene), Eppendorf Varipette 4720 (10 mL) & Biomaster 4830 (5 µL), Swagelok Alu-Plexiglas Fittings |
| Packaging | Ruggedized Portable Case with Modular Trays and Visual Identification System (Color-Coded by Matrix & Method) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | <1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (internally regulated) |
| Sampling System | Dual built-in pumps (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD screen |
| Interface | USB and/or RS232 |
| Digital I/O | TTL & digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limit | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software | WinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| OS Compatibility | Windows XP and later |
| Calibration Stability | Automated drift compensation over 12 months |
| Warranty | 1 year |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-FR |
| Detection Technologies | IMS, PID, MOS, EC |
| Sensor Channels | 8 independent parallel channels |
| Library Size | >300 calibrated chemical signatures |
| Response Time | <2 s (typical), ≤60 s (full quantification) |
| Detection Range | Sub-ppb to ppm level depending on analyte |
| Power | Rechargeable Li-ion battery, >8 h continuous operation |
| Compliance | CE, RoHS, ATEX Zone 2/22 (optional), IEC 61508 SIL2-ready architecture |
| Operating Temperature | −10 °C to +50 °C |
| Ingress Protection | IP65 |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Detection Principle | Hybrid IMS/PID/MOS/EC Sensor Fusion |
| Core Configuration | Multi-Channel VOC & Inorganic Gas Detector |
| Operating Temperature | −30 °C to 50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 8 h runtime) |
| Weight | 4.2 kg |
| Sample Introduction | Integrated Auto-Sampling Pump with Continuous Gas Flow |
| Cycle Time | 5 min |
| Response Time | 2–60 s |
| Detection Library | >300 Pre-Calibrated Compounds (VOCs, Inorganic Gases, Electronic Specialty Gases), Expandable |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Software | WinMuser GDA Suite |
| Heating Module | Integrated IR Heater for Solid/Surface Residue Volatilization |
| Alarm Logic | Template-Based Pattern Recognition with User-Configurable Thresholds |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3.5 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (Metal Oxide Semiconductor, Electrochemical, PID) |
| Sensor Array | 10 distinct MOS sensors |
| Software Platform | WinMuster v5.x |
| Data Analysis Algorithms | PCA, LDA, DFA, K-NN (Euclidean & Mahalanobis), PLS |
| Compliance | Designed for ISO 18562-3 (biocompatibility of gas pathways), ASTM E2147-22 (odor intensity measurement), GLP-compliant audit trail support |
| Operating Environment | 5–40 °C, 20–90% RH (non-condensing) |
| Sample Introduction | Integrated auto-sampling pump with mass-flow-controlled inlet (0.1–1.0 L/min adjustable) |
| Connectivity | USB 2.0, RS-232, optional Ethernet module for remote station integration |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Compliance | EN 13725:2003 |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array with Multivariate Pattern Recognition |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Data Transmission | Wi-Fi + Optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer and wind vane |
| Operating Mode | Fully Automated, Unattended 24/7 Monitoring |
| Software Algorithms | PCA, PLS, Mahalanobis Distance, Euclidean Distance |
| Sensor Configuration | 10-channel MOS sensor array |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Olfosense |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±1–2% |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 second |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC concentrations, user-selectable odorant(s) (1–2), and dimensionless odor unit (OU) values |
| Connectivity | WiFi/GSM/GPRS/3G |
| Data Integration | Open API, Modbus TCP/RTU, MQTT |
| Compliance | Designed for EN 13725-compliant odor assessment workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | M-IR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | meteo |
| Compliance | EN 13725 |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Sensor Array | 10 MOS (Metal Oxide Semiconductor) sensors |
| Data Acquisition | Continuous, 24/7 |
| Communication | Wi-Fi + optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer & wind vane |
| Software Algorithms | PCA, PLS regression, Mahalanobis & Euclidean distance analysis |
| Calibration Reference | EN 13725-compliant dynamic olfactometry |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA-FR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Sensor Array | 10 MOS metal oxide sensors |
| Odor Unit Quantification | OU/m³ per EN 13725 |
| Data Logging | Integrated DCR computer (Mini-ITX, 40 GB HDD, 512 MB RAM, Windows XP) |
| Connectivity | Wi-Fi + optional GSM/GPRS module for SMS alerts |
| Meteorological Integration | Co-located anemometer and wind vane with real-time digital output |
| Compliance | EN 13725:2003 certified odor quantification methodology |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±2% FS |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 s |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC, user-selectable target odorants (1–2), and dimensionless odor unit (OU) concentration |
| Communication Interfaces | WiFi, GSM, GPRS, 3G, Ethernet |
| Data Management | Cloud database, local LAN, or open-network deployment |
| Compliance Ready | Designed for integration into GLP/GMP- and ISO 16000-compliant environmental monitoring workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN 3.5 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | < 1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (integrated mass flow control) |
| Built-in Pumps | 2 (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD panel |
| Interface | USB and/or RS232 |
| Digital I/O | TTL and digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limits | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software Platform | WinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| Data Integrity | Audit-trail enabled |