Empowering Scientific Discovery

Beijing Yingsheng Hengtai Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelGDA-F
Weight2 kg
Sampling MethodAutomatic Continuous Sampling
Operating TemperatureAmbient (15–30 °C)
Detection Rangeppb to ppm
Target GasesCl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN3
Sensor Array10 metal oxide semiconductor (MOS) sensors
Sensor Volume1.8 mL
Operating Temperature110 °C (sensor tube)
Response Time<1 s
Measurement Cycle~60 s (20 s exposure + 40 s recovery)
Sampling Flow Rate10–400 mL/min (internally regulated)
Sampling SystemDual built-in pumps (sample + zero air)
Zero Air SourceActivated charcoal-filtered ambient air or zero-air generator
DisplayIntegrated LCD screen
InterfaceUSB and/or RS232
Digital I/OTTL & digital signal ports
Operating Ambient0–40 °C, 5–95% RH (non-condensing)
Power30 W, 110–230 V AC or optional 12 V DC
Weight2.3 kg
Dimensions255 × 190 × 92 mm
Safety ComplianceIEC 61010-1
Detection Limit0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene)
SoftwareWinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN)
OS CompatibilityWindows XP and later
Calibration StabilityAutomated drift compensation over 12 months
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Modelmeteo
ComplianceEN 13725
Output UnitOdor Units per cubic meter (OU/m³)
Sensor Array10 MOS (Metal Oxide Semiconductor) sensors
Data AcquisitionContinuous, 24/7
CommunicationWi-Fi + optional GSM/GPRS
Meteorological IntegrationIntegrated anemometer & wind vane
Software AlgorithmsPCA, PLS regression, Mahalanobis & Euclidean distance analysis
Calibration ReferenceEN 13725-compliant dynamic olfactometry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
ModelPEN 3.5
Sensor Array10 metal oxide semiconductor (MOS) sensors
Sensor Volume1.8 mL
Operating Temperature110 °C (sensor tube)
Response Time< 1 s
Measurement Cycle~60 s (20 s exposure + 40 s recovery)
Sampling Flow Rate10–400 mL/min (integrated mass flow control)
Built-in Pumps2 (sample + zero air)
Zero Air SourceActivated charcoal-filtered ambient air or zero-air generator
DisplayIntegrated LCD panel
InterfaceUSB and/or RS232
Digital I/OTTL and digital signal ports
Operating Ambient0–40 °C, 5–95% RH (non-condensing)
Power30 W, 110–230 V AC or optional 12 V DC
Weight2.3 kg
Dimensions255 × 190 × 92 mm
Safety ComplianceIEC 61010-1
Detection Limits0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene)
Software PlatformWinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN)
Data IntegrityAudit-trail enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRSENSE
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelGDA-X
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0