Empowering Scientific Discovery

Biolin Scientific AB

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
ModelTheta Lite
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Sample Stage DimensionsUnlimited (W) × 50 mm (D) × 200 mm (L)
Image Resolution744 × 480 pixels
Magnification744 pixel/mm × 480 pixel/mm
Surface/Interfacial Tension Range0.01–2000 mN/m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
ModelTheta Wafer
Instrument TypeBenchtop Video Optical Contact Angle Analyzer
Measurement CapabilitiesContact Angle, Surface Tension, Interfacial Tension, Surface Free Energy
Contact Angle Accuracy±0.1°
Contact Angle Resolution2592 × 2048 (5 MP)
Maximum Sample Size12-inch wafer
Sample Stage Load Capacity500 g
Rotational Range0–360°
Maximum Rotation Speed180°/s
Angular Resolution0.005°
Vacuum InterfaceYes
Automated PositioningYes
Camera Frame RateUp to 3422 fps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
Model3D Topography Module
Instrument TypeBenchtop Dynamic Contact Angle & Surface Topography System
Contact Angle Range0–180°
Contact Angle Accuracy±0.1° (standard), ±0.01° (high-resolution mode)
Sample Stage Dimensions75 × 75 mm
Optical Magnification0.7×–4.5×
Surface Tension Range0–2000 mN/m
Z-Range Measurement1–60 µm
Lateral Sampling Area1.41 mm × 1.06 mm (single frame)
XY Pixel Resolution1.1 µm × 1.1 µm
Working Distance18 mm
Max Sample Height22 mm
Max Sample Width180 mm
Measurement Time per Point5–30 s (at 1280 × 960 resolution)
Roughness Parameters Compliant WithISO 4287, ISO 4288, ISO 11562
Required Hardware InterfaceFireWire (IEEE 1394) or PCI slot
Sample RequirementDiffusely reflective surface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
ModelHigh Pressure Chamber
Instrument TypeBenchtop Laboratory System
Contact Angle Range0.1–179.9°
Contact Angle Accuracy±0.1°
Sample Stage Dimensions10 × 10 mm
Image Resolution782 × 582 pixels/mm
Surface/Interfacial Tension Range0.01–1000 mN/m
Max Operating Pressure400 bar
Temperature Range1–200 °C
Chamber Volume77 mL (without piston), 45 mL (with piston)
Pressure Control MethodPrecision Piston Actuation or Gas/Liquid Injection
Construction MaterialCertified Stainless Steel (CE Compliant)
Dimensions (Theta + Chamber)74 × 25 × 61 cm (L×W×H)
Weight16 kg
Power Supply100–240 V AC, 50–60 Hz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0