Empowering Scientific Discovery

Biolin Scientific AB

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
ModelCustomized QSensor
Surface Coating OptionsCOP, EVA, FEP, PC, LDPE, PP, PUR, PES, PVC, CeO₂, SiGe, Cr22 Duplex Stainless Steel, Ti-6Al-4V, Ilmenite, Montmorillonite, WC, SnO₂, Pyrophyllite, Mg(OH)₂, AlO(OH), CuS, FeS, Carbon Soot, Sb₂S₃, SrSO₄, Clay
Certification ComplianceISO 9001–certified manufacturing, GLP-compatible documentation support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQSensor
Price RangeUSD 1–9,999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelKSV NIMA Brewster Angle Microscope
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeManufacturer
Origin CategoryImported
ModelSchaefer
Price RangeUSD 25,000 – 63,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelKSV NIMA ISR Flip
Instrument TypeInterfacial Rheometer
Sample Viscosity RangeLow-viscosity liquids
Sample StateLiquid
Bearing TypeMechanical bearing
Frequency Range0.01–10 Hz
Torque Resolution0.001 mN·m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelMicroBAM
Price RangeUSD 2,800 – 7,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
CategoryImported Instrument
ModelKN2004 Large-Scale Alternating
Measurement Range0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod)
Surface Area per Trough930 cm² × 2
Subphase Volume6000 mL
Temperature Control Range−10 °C to +60 °C
Barrier Speed0.1–200 mm/min
Barrier Speed Accuracy±0.1 mm/min
Deposition Speed0.1–85 mm/min
Balance Max Load1 g
Force Sensitivity0.1 μN/m
Trough Dimensions (L×W×H)775 × 120 × 10 mm × 2
Dipping Well Radius133 mm, Depth: 128 mm
Max Substrate Size3 × 129 × 114 mm or 4-inch wafer
Frame Height Adjustment33 mm
XYZ Positioning Range for Balance360° rotation, 110 mm (X), 45 mm (Y/Z)
Power Supply100–240 VAC, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
ModelExplorer
Minimum Sample Volume40 µL
Temperature Range15–65 °C
Frequency Range1–70 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
ModelAnalyzer
Minimum Sample Volume40 µL
Temperature Range15–65 °C
Frequency Range1–70 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelRibbon-Type LB Trough
Price RangeUSD 1,400 – 2,800
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelLangmuir Trough All-Size
Price RangeUSD 2,700 – 6,800 (FOB Helsinki)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginFinland
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelQSense Initiator
PriceUpon Request
Minimum Sample Volume40 µL
Temperature Range15–65 °C
Frequency Range1–70 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
ModelQSensors
Instrument TypeMicrofluidic Chip System
Chip Surface Types18 Standard Coatings (e.g., Au, SiO₂, TiO₂, Al₂O₃, Cr, Ni, PMMA, PEI, NHS, Biotin, Hydroxyapatite, etc.)
Manufacturing SiteGothenburg, Sweden
ComplianceDesigned for ISO/IEC 17025-aligned QCM-D workflows
Application DomainSurface science, biomolecular interaction analysis, electrochemistry, environmental interfaces, energy materials, and pharmaceutical formulation studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
ModelOmni
Minimum Sample Volume90 µL
Temperature Range4–70 °C
Frequency Range1–72 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelRibbon-Type Langmuir Trough
Measurement Range0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod)
Surface Area (Expanded)148.4 cm²
Surface Area (Compressed)40.5 cm²
Trough Dimensions (L×W×H)358 × 90 × 10 mm
Barrier Speed0.1–270 mm/min
Speed Accuracy±0.1 mm/min
Force Resolution0.1 μN/m
Balance Load Capacity1 g
Wilhelmy PlatePt, W19.62 × H10 mm (EN 14370:2004 compliant)
Subphase Volume322 mL
Power Supply100–240 VAC, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelLangmuir-Blodgett Deposition Trough
Price RangeUSD 2,700 – 6,800 (FOB Helsinki)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelAttension Theta Flow
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.01°
Sample Stage DimensionsUnlimited × 100 × 320 mm (L×W×H)
Image MagnificationSelectable Options
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.1 mN/m, ±0.01 mN/m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginFinland
ModelPro
Minimum Sample Volume40 µL
Temperature Range15–65 °C
Frequency Range1–70 MHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
CategoryImported Instrument
Model VariantCompact and Standard Configurations
Price RangeUSD 6,800 – 13,600 (FOB Helsinki)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKSV NIMA
OriginFinland
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
CategoryImported Instrument
ModelKN2006 Dual-Trough Alternating
Voltage100–240 VAC, 50–60 Hz
Trough Surface Area587 cm² × 2
Internal Trough Dimensions782 × 75 × 5 mm (L × W × H) × 2
Barrier Speed0.1–200 mm/min
Barrier Speed Accuracy±0.1 mm/min
Surface Pressure Range0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod)
Balance Max Load1 g
Balance PositioningXYZ adjustable (360° rotation, 110 mm X, 45 mm Y/Z)
Sensor Resolution0.1 μN/m
Wilhelmy Plate StandardW19.62 × H10 mm, compliant with EN 14370:2004
Subphase Volume per Trough1400 mL
Dipper Well GeometrySemi-circular, radius 75 mm, depth 74 mm
Max Substrate Size3 × 30 × 50 mm
Deposition Speed0.1–85 mm/min
Trough MaterialSolid-sintered, pore-free PTFE with integrated water-jacket interface
Frame Height Adjustment33 mm
Modular Interface PortspH probe, syringe injection, stirring, BAM/PM-IRRAS/ISR coupling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQSense
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQSense High Pressure
QuotationUpon Request
Minimum Sample Volume100 µL
Temperature Range15–150 °C
Frequency Range1–70 MHz
Max. Operating Pressure200 bar
Temperature Stability±0.02 °C (software-controlled)
Time Resolution>100 data points/sec per frequency
Liquid-phase Mass Sensitivity<1 ng/cm²
Liquid-phase Dissipation Sensitivity<0.08 × 10⁻⁶
Chip Surface Options>50 standard materials (Au, SiO₂, stainless steel SS2343/SS2348, Fe₂O₃, kaolinite, etc.), custom substrates available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiolin Scientific
OriginFinland
ModelTheta Flex
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Sample Stage Dimensions105 mm × 105 mm
Image MagnificationConfigurable Lens Options
Surface/Interfacial Tension Range0.01–2000 mN/m
Surface/Interfacial Tension Accuracy±0.1 mN/m (high range), ±0.01 mN/m (low range)
Camera Resolution1984 × 1264 pixels
Max Frame Rate3009 fps
Light SourceHigh-Power Monochromatic LED
SoftwareOneAttension v5.x
ComplianceFully compatible with GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
Model703D
Measurement PrincipleWilhelmy Plate/Ring Method (Force Balance)
DisplayIntegrated High-Resolution Digital Screen
Operation ModeStandalone Manual Operation (PC Optional)
Temperature Control SupportYes (via Jacketed Cell, Immersion Probe, Vapor Phase Chamber)
Compliance StandardsASTM D971, ISO 1409, ISO 6295, USP <1046>, EN 14370
Data OutputReal-time on-screen display, USB export, optional printer interface
Accessories IncludedPlatinum Plate, Platinum Ring, Density Sphere, Calibration Kit, Ring Correction Tool, Glass Beakers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAttension
OriginFinland
ModelTheta Lite
Instrument TypeBenchtop Video-Based Optical Contact Angle Analyzer
Contact Angle Range0–180°
Contact Angle Accuracy±0.1°
Sample Stage DimensionsUnlimited (W) × 50 mm (D) × 200 mm (L)
Image Resolution744 × 480 pixels
Magnification744 pixel/mm × 480 pixel/mm
Surface/Interfacial Tension Range0.01–2000 mN/m
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0