- All
- Favorite
- Popular
- Most rated
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Schaefer |
| Price Range | USD 25,000 – 63,000 |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroBAM |
| Price Range | USD 2,800 – 7,000 |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | KN2004 Large-Scale Alternating |
| Measurement Range | 0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod) |
| Surface Area per Trough | 930 cm² × 2 |
| Subphase Volume | 6000 mL |
| Temperature Control Range | −10 °C to +60 °C |
| Barrier Speed | 0.1–200 mm/min |
| Barrier Speed Accuracy | ±0.1 mm/min |
| Deposition Speed | 0.1–85 mm/min |
| Balance Max Load | 1 g |
| Force Sensitivity | 0.1 μN/m |
| Trough Dimensions (L×W×H) | 775 × 120 × 10 mm × 2 |
| Dipping Well Radius | 133 mm, Depth: 128 mm |
| Max Substrate Size | 3 × 129 × 114 mm or 4-inch wafer |
| Frame Height Adjustment | 33 mm |
| XYZ Positioning Range for Balance | 360° rotation, 110 mm (X), 45 mm (Y/Z) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Ribbon-Type LB Trough |
| Price Range | USD 1,400 – 2,800 |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Langmuir Trough All-Size |
| Price Range | USD 2,700 – 6,800 (FOB Helsinki) |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Ribbon-Type Langmuir Trough |
| Measurement Range | 0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod) |
| Surface Area (Expanded) | 148.4 cm² |
| Surface Area (Compressed) | 40.5 cm² |
| Trough Dimensions (L×W×H) | 358 × 90 × 10 mm |
| Barrier Speed | 0.1–270 mm/min |
| Speed Accuracy | ±0.1 mm/min |
| Force Resolution | 0.1 μN/m |
| Balance Load Capacity | 1 g |
| Wilhelmy Plate | Pt, W19.62 × H10 mm (EN 14370:2004 compliant) |
| Subphase Volume | 322 mL |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Langmuir-Blodgett Deposition Trough |
| Price Range | USD 2,700 – 6,800 (FOB Helsinki) |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Attension Theta Flow |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Sample Stage Dimensions | Unlimited × 100 × 320 mm (L×W×H) |
| Image Magnification | Selectable Options |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m, ±0.01 mN/m |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model Variant | Compact and Standard Configurations |
| Price Range | USD 6,800 – 13,600 (FOB Helsinki) |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | KN2006 Dual-Trough Alternating |
| Voltage | 100–240 VAC, 50–60 Hz |
| Trough Surface Area | 587 cm² × 2 |
| Internal Trough Dimensions | 782 × 75 × 5 mm (L × W × H) × 2 |
| Barrier Speed | 0.1–200 mm/min |
| Barrier Speed Accuracy | ±0.1 mm/min |
| Surface Pressure Range | 0–300 mN/m (Pt plate), 0–1000 mN/m (Pt rod) |
| Balance Max Load | 1 g |
| Balance Positioning | XYZ adjustable (360° rotation, 110 mm X, 45 mm Y/Z) |
| Sensor Resolution | 0.1 μN/m |
| Wilhelmy Plate Standard | W19.62 × H10 mm, compliant with EN 14370:2004 |
| Subphase Volume per Trough | 1400 mL |
| Dipper Well Geometry | Semi-circular, radius 75 mm, depth 74 mm |
| Max Substrate Size | 3 × 30 × 50 mm |
| Deposition Speed | 0.1–85 mm/min |
| Trough Material | Solid-sintered, pore-free PTFE with integrated water-jacket interface |
| Frame Height Adjustment | 33 mm |
| Modular Interface Ports | pH probe, syringe injection, stirring, BAM/PM-IRRAS/ISR coupling |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 105 mm × 105 mm |
| Image Magnification | Configurable Lens Options |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (high range), ±0.01 mN/m (low range) |
| Camera Resolution | 1984 × 1264 pixels |
| Max Frame Rate | 3009 fps |
| Light Source | High-Power Monochromatic LED |
| Software | OneAttension v5.x |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | 703D |
| Measurement Principle | Wilhelmy Plate/Ring Method (Force Balance) |
| Display | Integrated High-Resolution Digital Screen |
| Operation Mode | Standalone Manual Operation (PC Optional) |
| Temperature Control Support | Yes (via Jacketed Cell, Immersion Probe, Vapor Phase Chamber) |
| Compliance Standards | ASTM D971, ISO 1409, ISO 6295, USP <1046>, EN 14370 |
| Data Output | Real-time on-screen display, USB export, optional printer interface |
| Accessories Included | Platinum Plate, Platinum Ring, Density Sphere, Calibration Kit, Ring Correction Tool, Glass Beakers |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | Unlimited (W) × 50 mm (D) × 200 mm (L) |
| Image Resolution | 744 × 480 pixels |
| Magnification | 744 pixel/mm × 480 pixel/mm |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Theta Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Measurement Capabilities | Contact Angle, Surface Tension, Interfacial Tension, Surface Free Energy |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5 MP) |
| Maximum Sample Size | 12-inch wafer |
| Sample Stage Load Capacity | 500 g |
| Rotational Range | 0–360° |
| Maximum Rotation Speed | 180°/s |
| Angular Resolution | 0.005° |
| Vacuum Interface | Yes |
| Automated Positioning | Yes |
| Camera Frame Rate | Up to 3422 fps |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Principle | Wilhelmy Plate / Du Noüy Ring Method (Force-Based Gravimetric) |
| Temperature Control Options | Thermostatted Jacket, Immersion Probe, Vapor-Phase Chamber |
| Compliance Standards | ASTM D971, ISO 6295, ISO 1409, USP <1058> (for instrument qualification), GLP/GMP-ready data traceability |
| Data Output | Real-time digital display + USB/RS-232 export + optional printer interface |
| Accessories Included | Platinum plate, platinum ring, density sphere, calibration kit, ring correction tool, standard glass beakers |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | Surface/Interfacial Tension (0.01–2000 mN/m), Dynamic Contact Angle (0°–180°), CMC Detection, Solid Surface Free Energy, Powder Wettability, Sedimentation Rate, Liquid Density |
| Resolution | 0.001 mN/m (tension), 0.01° (contact angle) |
| Balance Capacity | 210 g |
| Temperature Control | –20 °C to +200 °C (with jacketed cell or air bath) |
| Compliance | ASTM D971, ISO 1409, ISO 6295, USP <1046>, GLP/GMP-ready data audit trail |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | 3D Topography Module |
| Instrument Type | Benchtop Dynamic Contact Angle & Surface Topography System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-resolution mode) |
| Sample Stage Dimensions | 75 × 75 mm |
| Optical Magnification | 0.7×–4.5× |
| Surface Tension Range | 0–2000 mN/m |
| Z-Range Measurement | 1–60 µm |
| Lateral Sampling Area | 1.41 mm × 1.06 mm (single frame) |
| XY Pixel Resolution | 1.1 µm × 1.1 µm |
| Working Distance | 18 mm |
| Max Sample Height | 22 mm |
| Max Sample Width | 180 mm |
| Measurement Time per Point | 5–30 s (at 1280 × 960 resolution) |
| Roughness Parameters Compliant With | ISO 4287, ISO 4288, ISO 11562 |
| Required Hardware Interface | FireWire (IEEE 1394) or PCI slot |
| Sample Requirement | Diffusely reflective surface |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 10 × 10 mm |
| Image Resolution | 782 × 582 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Max Operating Pressure | 400 bar |
| Temperature Range | 1–200 °C |
| Chamber Volume | 77 mL (without piston), 45 mL (with piston) |
| Pressure Control Method | Precision Piston Actuation or Gas/Liquid Injection |
| Construction Material | Certified Stainless Steel (CE Compliant) |
| Dimensions (Theta + Chamber) | 74 × 25 × 61 cm (L×W×H) |
| Weight | 16 kg |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Maximum Sample Weight | 5.0 g |
| Resolution | 0.001 mg |
| Surface Tension Range | 0–1000 mN/m |
| Surface Tension Resolution | 0.001 mN/m |
| Stage Vertical Speed | 0.01–500 mm/min |
| Standard Sample Vessel Diameter | 50 mm or 70 mm |
| Temperature Range | −10 to +100 °C (standard), optional −30 to +130 °C or ambient to +250 °C |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Principle | Wilhelmy Plate / Du Noüy Ring Method (Force-Based Gravimetric) |
| Compliance | ASTM D971 (Oil-Water Interfacial Tension), ISO 1409, ISO 6295, USP <1058> (for instrument qualification) |
| Temperature Control Options | Circulating bath jacket, integrated temperature probe, vapor-phase temperature control |
| Key Measurables | Surface Tension (mN/m), Interfacial Tension (mN/m), Critical Micelle Concentration (CMC), Dynamic Contact Angle (°), Solid Surface Free Energy (mJ/m²), Powder Wettability (via Washburn method), Sedimentation Rate (mg/s), Liquid Density (g/cm³) |
| Display | Integrated high-resolution LCD with real-time force and tension readout |
| Data Output | USB interface, optional direct thermal printer connection, bundled Attension OneTouch™ software for data logging, CMC curve fitting, and ASTM D971 report generation |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer | KSV NIMA (a brand of Biolin Scientific AB) |
| Product Category | Imported Instrument |
| Model | Microscopy Troughs |
| Price Range | USD 2,700 – 6,800 (FOB Helsinki) |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | Roll-to-Roll |
| Price Range | USD 13,500 – 27,000 |
Show next