Beckman Coulter
Filter
Showing 31–60 of 77 results
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CytoFLEX mosaic |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Spectral Flow Cytometer |
| Application Domain | Research |
| Lasers | 4–6 |
| Detection Channels | 63–88 |
| Optical Resolution | 80 nm |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Acquisition Rate | 30,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 10–240 µL/min |
| Compensation Method | Real-time Automatic Compensation & On-the-fly Spectral Unmixing |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Product Category | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Coefficient of Variation (rCV) | <10% |
| Fluorescence Sensitivity (8-peak calibration beads) | V447: 8 peaks |
| 8531 | 8 peaks |
| Y595 | 8 peaks |
| R670 | 6 peaks |
| R710 | 5 peaks |
| R792 | 4 peaks |
| Sample Acquisition Rate | 16,000 events/sec |
| Automated Sample Loading | Yes |
| Sample Flow Rate | 6 µL/min |
| Compensation Method | Automatic |
| Brand | Beckman Coulter |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Side Scatter (SSC) Detection Channels | 5 |
| Particle Size Detection Range | 40 nm – 1 µm |
| Automated Sample Loading | Yes |
| Compensation Method | Fully Automated |
| Sorting Capability | Optional |
| Sorting Output Ports | 6-way |
| Voltage Adjustment Required | No |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CytoFLEX S Series |
| Technology Pathway | Analytical Flow Cytometry |
| Product Type | Flow Cytometry Analyzer |
| Primary Use Case | Research |
| Laser Configuration | Up to four spatially separated lasers (375 nm, 405 nm, 488 nm, 561 nm) |
| Fluorescence Detection Channels | Up to 13 parameters with full-channel rCV < 3% |
| Optical Resolution | Side Scatter (488 nm) < 300 nm, Violet Side Scatter (405 nm) < 80 nm (vs. polystyrene beads) |
| Sample Flow Rate | 10–240 µL/min (user-selectable in 10/30/60 µL/min presets or fully adjustable) |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Event Acquisition Rate | Up to 30,000 events/sec (continuous, software-adjustable) |
| Automated Sample Loading | Integrated plate-based autosampler optional |
| Compensation Method | Real-time automatic compensation with saved compensation matrices |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Sorting Flow Cytometer |
| Application Domain | Research |
| Laser Configuration | Up to 4 Lasers (405 nm, 488 nm, 561 nm, 638 nm) |
| Fluorescence Detection Channels | 15 Total (Configurable BPF Filters) |
| Optical Precision | rCV < 3% across all channels |
| Side Scatter Resolution | < 300 nm (488 nm excitation), < 200 nm (405 nm excitation) |
| Sample Flow Rate | 10–100 µL/min |
| FITC Sensitivity (488 nm) | < 30 MESF |
| Cell Acquisition Rate | 40,000 events/sec |
| Sorting Throughput | 30,000 cells/sec |
| Nozzle Diameter | 100 µm |
| Droplet Frequency | 35 kHz |
| Sorting Logic | Quadruple-Stream Sorting with Mixed-Mode and Discard-Capture Capability |
| Compensation | Fully Automated Real-Time Compensation |
| Sample Loading | Integrated Auto-Sampler (40,000 events/sec loading speed) |
| Voltage Adjustment Required | No |
| Biosafety Options | Optional Aerosol Containment Cabinet or Standalone Aerosol Exhaust System |
| Software Platform | CytExpert for CytoFLEX SRT (FDA 21 CFR Part 11–Ready Audit Trail, GLP/GMP-Compliant Data Integrity Features) |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic IVD Instrument |
| Model | DxFLEX |
| Product Category | Clinical Flow Cytometry System |
| Application Domain | In Vitro Diagnostic (IVD) Laboratories |
| Laser Configuration | 3 Lasers / 13 Fluorescence Parameters |
| Fluorescence Sensitivity | ≤30,000 Equivalent Stained Particles (ESPs) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ECHO 6XX |
| Deck Positions | 2 |
| Pipetting Accuracy | <8% CV |
| Pipetting Range | 2.5 nL – 5 µL |
| Throughput | Up to 750,000 samples per day |
| Dimensions (W×D×H) | 53.9 cm × 68.3 cm × 92.5 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | EPICS XL / XL-MCL |
| Product Type | Flow Cytometry Analyzer |
| Regulatory Classification | Imported Instrument |
| Software Platform | System II™ |
| Detection Capability | 4-color fluorescence, multi-parameter analysis |
| Sample Throughput (XL-MCL) | Up to 100 samples/hour |
| Fluidics Architecture | Closed-system design with pre-aspirational mixing and barcode-enabled tri-channel positive sample identification |
| Optical Configuration | Interchangeable filter sets for flexible assay configuration |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F0650 |
| Instrument Type | Benchtop Centrifuge |
| Maximum Capacity | 6 × 50 mL |
| Maximum Speed | 21,000 rpm (with Allegra 64R) |
| Maximum RCF | 41,400 × g (with Allegra 64R) |
| Rotor Type | Fixed-Angle |
| k-Factor | 795 |
| BioC Certification | Not Applicable |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | F1010 |
| Instrument Type | Benchtop Centrifuge Rotor |
| Rotor Type | Fixed-Angle |
| Max Capacity | 10 × 10 mL |
| Max Speed | 26,000 rpm |
| Max RCF | 57,440 × g |
| k-Factor | 500 |
| Compatible Systems | Allegra 64R and Allegra X-30 Series Centrifuges |
| BioC Certification | Not Applicable |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Gallios |
| Product Type | Flow Cytometry Analyzer |
| Category | Cell Analysis Instrument |
| Import Status | Imported |
| Distribution Model | Authorized Distributor |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HIAC 9703+ |
| Instrument Type | Optical Liquid Particle Counter |
| Sample Volume Range | 1 mL to 1000 mL |
| Particle Size Detection Range | 0.5 µm to 600 µm |
| Regulatory Compliance | FDA 21 CFR Part 11, ISO 21501-4 |
| Preconfigured Pharmacopoeial Methods | USP <788>, USP <789>, EP 2.9.19, JP 6.07, KP 5.2.10 |
| Software | PharmSpec v5.x with Audit Trail, Electronic Signatures, and Automated Backup/Restore |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | J6 |
| Maximum RCF | 6,835 × g |
| Maximum Speed | 6,000 rpm |
| Microprocessor Control | Yes |
| Acceleration/Deceleration Rates | 9/9 |
| Programmable Methods | 10 |
| Brushless Drive Motor | Yes |
| Capacity | 6 L (e.g., 12 blood bags, 18 microplates, or 336 RIA tubes) |
| Rotor Compatibility | JS-4.2A, JS-4.2SMA ARIES (auto-balancing within ±50 g), JE-6B & JE-5.0 elutriation rotors |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LS 13 320 XR |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 10 nm – 3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | 10 seconds |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | LS Series |
| Measurement Range | 17 nm – 2000 µm |
| Accuracy | < 1% |
| Repeatability | < 1% |
| Resolution | Capable of resolving two peaks with a peak diameter ratio > 2.5 |
| Detection Channels | 116 |
| Detector Array | 132 photodiode detectors |
| Light Source | Solid-state laser (rated lifetime > 70,000 hours) |
| Optical Design | Dual-lens patented configuration with multi-wavelength and polarized light capability |
| Sample Introduction | Dry dispersion and wet suspension modes supported |
| Compliance | Designed to support ISO 13320, ASTM E2412, and USP <429> requirements for particle size distribution analysis |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MET ONE 3400+ |
| Instrument Type | Optical Particle Counter |
| Flow Rates | 28.3 L/min, 50 L/min, 100 L/min |
| Standard Sizing Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (model-dependent) |
| Laser Source | Long-life laser diode (MTBF ≥ 10 years) |
| Power | AC input 80–264 VAC |
| Dimensions | 26.7 × 26 × 21 cm (10.5" × 10.25" × 8.25") |
| Weight | 5.6 kg (no battery), 6.9 kg (with 2 cells) |
| Enclosure | 316 stainless steel |
| Operating Environment | 0–40°C, 10–90% RH (non-condensing) |
| Compliance | FDA 21 CFR Part 11 ready, ISO 21501-4, ISO 14644-1, EU GMP Annex 1 compatible |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000 |
| Instrument Type | Optical Airborne Particle Counter |
| Particle Size Channels | Standard 2-channel (0.3 µm & 0.5 µm), optional 4-channel configuration |
| Light Source | Long-life laser diode |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × L × H) |
| Weight | 0.68 kg |
| Housing Material | 304 stainless steel |
| Power Supply | 9–28 VDC |
| Max. Power Consumption | 3.3 W (serial/pulse), 4.3 W (Ethernet) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Flow Control | Precision orifice-based |
| Flow Rate Options | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Counting Efficiency | ≥50% at 0.3 µm |
| Coincidence Loss | ≤5% at 2×10⁶ particles/ft³ (7.06×10⁷ particles/m³) for 6002/6003 variants |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Pulse output, 4–20 mA analog, RS-232, RS-485 (Modbus RTU or FXB), Ethernet TCP/IP |
| Diagnostic Indicators | Multi-color LED status indicator (normal operation, count alarm, sensor fault, flow fault, comms fault) |
| Optional Sensors | Integrated temperature and relative humidity (RH/T) probe |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MET ONE 6000P |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 cfm or 1.0 cfm |
| Sizing Thresholds | 0.3 µm and 0.5 µm |
| Channel Configurations | Standard 2-channel or optional 4-channel |
| Light Source | Long-life laser diode |
| Housing Material | Stainless steel |
| Dimensions | 17.15 × 11.43 × 31.75 cm (W × D × H) |
| Weight | 4.62 kg (10.2 lb) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max. Power Consumption | 50 W (DC), 7.9 W (AC) |
| Operating Temperature | 10–32 °C |
| Operating Humidity | 5–95% RH, non-condensing |
| Storage Temperature | −40–70 °C |
| Storage Humidity | 5–98% RH, non-condensing |
| Counting Efficiency Loss | ≤5% at 2×10⁶ particles/ft³ (7.1×10⁷ particles/m³) and at 4×10⁵ particles/ft³ (1.4×10⁷ particles/m³) |
| False Count Rate | ≤1 particle per 5 minutes |
| Flow Control | Microprocessor-based with differential pressure sensor |
| Pump Type | Integrated vacuum pump |
| Compliance | ISO 21501-4:2018, ISO 14644-1:2015, FDA 21 CFR Part 11 (data integrity support), EU GMP Annex 1 (2022) alignment |
| Output Interfaces | 4–20 mA analog, Ethernet TCP/IP, Modbus RTU (RS-485), pulse output, optional wireless modules |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MET ONE 7000 |
| Instrument Type | Optical Airborne Particle Counter |
| Flow Rate Options | 0.1 CFM or 1.0 CFM |
| Particle Size Sensitivity | 0.5 µm |
| Channel Configurations | 2-channel or 4-channel selectable |
| Light Source | Long-life laser diode |
| Housing Material | Electropolished stainless steel, VHP-resistant optics |
| Compliance | ISO 21501-4, ISO 14644-1/2, IEST-RP-CC021.1, FDA 21 CFR Part 11 (with optional audit trail software), GMP-environment validated design |
| Operating Temperature | 10–32 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 24 VDC ±10% or 100–230 VAC, 50/60 Hz |
| Max Power Consumption | 6.9 W (Ethernet DC), 12.5 W (Wireless AC) |
| Vacuum Requirement | ≥40.6 cm Hg |
| Flow Control | Precision orifice-based |
| Counting Loss | ≤5% at 2×10⁶ particles/ft³ (7005 variant) or 4×10⁵ particles/ft³ (7015 variant) |
| False Count Rate | ≤1 particle per 5 minutes |
| Communication Interfaces | Ethernet TCP/IP, RS-485 Modbus RTU/FXB, 4–20 mA analog output, wireless (optional) |
| Enclosure Rating | NEMA 4X |
| Weight | 3.73 kg (AC), 3.67 kg (DC) |
| Dimensions | 22.9 W × 12.5 D × 16.0 H cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 2+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.5–5.0 µm |
| Channels | 2 |
| Flow Rate | 2.83 L/min |
| Counting Efficiency | 50% at 0.5 µm, 100% ≥0.75 µm (per ISO 21501-4) |
| Zero Count Level | ≤1 count / 5 min (per JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ (10% coincidence loss, per ISO 21501-4) |
| Data Storage Capacity | 10,000 records |
| Display | 3.5″ color TFT, 320 × 240 pixels |
| Operating Temperature | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | >10 h typical, ≥5.5 h continuous |
| Dimensions | 10.7″ × 3.9″ × 2.1″ |
| Weight | 1.5 lbs (0.68 kg) |
| Enclosure Material | Polycarbonate-ABS blend |
| Compliance | ISO 14644-1, ISO 21501-4, JIS B9921, FS 209E |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported |
| Model | MET ONE HHPC 6+ |
| Instrument Category | Optical Particle Counter |
| Particle Size Range | 0.3–10 µm (6 channels per ISO 14644-1 & ISO 21501) |
| Flow Rate | 2.83 L/min |
| Weight | 1.5 lbs (0.68 kg) |
| Display | 3.5" color LCD (320 × 240) |
| Data Storage | 10,000 records |
| Counting Efficiency | 50% at 0.3 µm |
| Zero Count Level | ≤1 count/5 min (JIS B9921) |
| Maximum Concentration Limit | 4,000,000 particles/ft³ with <10% coincidence loss (ISO 21501) |
| Operating Environment | 10–40 °C, ≤95% RH (non-condensing) |
| Battery Life | ≥10 h typical, ≥5.5 h minimum continuous |
| Charging Time | 3.5 h |
| Housing Material | Polycarbonate-ABS blend |
| Dimensions | 10.7" × 3.9" × 2.1" (272 × 99 × 53 mm) |
| Connectivity | USB 2.0, Ethernet (HTTP-based web interface), USB flash drive support |
| User Interface Languages | English, Japanese |
| Alarm Configuration | User-defined particle count thresholds |
| Security | Optional administrator password protection |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MET ONE R4800/R4900 |
| Instrument Type | Optical Particle Counter |
| Minimum Detectable Size | 0.3 µm (R4803/R4903) or 0.5 µm (R4805/R4815/R4905/R4915) |
| Flow Rate | 0.1 CFM (2.83 L/min) or 1.0 CFM (28.3 L/min) |
| Detection Principle | Laser Diode-Based Light Scattering |
| Channel Configuration | Dual-channel (e.g., 0.3/0.5 µm or 0.5/5.0 µm) |
| Counting Efficiency Loss | <5% at 2×10⁶ particles/ft³ |
| Operating Temperature | 12–41°C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Interface | Open-collector FET output (max. 150 mA sink, 30 VDC off-state) |
| Communication | RS-485 (R4800 series) or 4–20 mA analog (R4900 series) |
| Housing Material | Stainless steel |
| Weight | 0.3 kg |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm) |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 20,627 × g |
| Maximum Capacity | 36 × 2.0 mL |
| Dimensions (W × D × H) | 31.0 × 42.0 × 27.0 cm |
| Temperature Range | 5–40 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 s to 99 min 59 s (or continuous) |
| Display | Simultaneous rpm and RCF readout |
| Rotor Compatibility | FA361.5 fixed-angle rotor (standard), plus three additional optional rotors |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Microfuge 20 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Maximum RCF | 20,627 × g |
| Maximum Capacity | 36 × 1.5/2.0 mL tubes |
| Temperature Control | Non-refrigerated (Microfuge 20) |
| Rotor Options | 4 interchangeable fixed-angle rotors including biocontainment-certified rotor |
| Dimensions (W×D×H) | 31 × 42 × 27 cm |
| Compliance | Meets IEC 61010-1 safety standards |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Benchtop Refrigerated Centrifuge |
| Model | Microfuge 20R |
| Centrifuge Category | High-Speed Refrigerated Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 20,627 × g |
| Max Capacity | 36 × 2.0 mL |
| Dimensions (W × D × H) | 31 × 66 × 29.1 cm |
| Rotor Type | Fixed-Angle (e.g., FA361.5) |
| Application Scope | Cellular & bacterial pelleting, nucleic acid/protein isolation, subcellular fractionation, phase separation, receptor binding assays, and particulate sedimentation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Microfuge® 16 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Microcentrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Cellular & Bacterial Pelletation |
| Maximum Capacity | 24 × 2.0 mL |
| Maximum Speed | 14,800 rpm |
| Maximum RCF | 16,163 × g |
| Dimensions (W × D × H) | 22.6 cm × 26.6 cm × 17.6 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | MoFlo XDP |
| Product Category | High-Performance Flow Cytometry-Based Cell Sorting System |
| Sample Size Range | 0.5–50 µm |
| Maximum Analysis Rate | >100,000 cells/sec |
| Maximum Sorting Rate | >70,000 cells/sec |
| Fluorescence Parameters | Up to 18 colors + 2 scatter channels (with multi-laser configuration) |
| Sorting Output | 4-way simultaneous sorting |
| Nozzle Options | 8 interchangeable nozzles (50–200 µm) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multisizer 4e |
| Instrument Type | Electrical Sensing Zone (ESZ) Particle Analyzer |
| Measurement Principle | Coulter Principle (Electrical Sensing Zone) |
| Size Range | 0.4 µm – 1600 µm (diameter) |
| Volume Range | 0.033 fL – 2.145 × 10⁹ fL |
| Resolution | Up to 400 user-selectable channels |
| Compliance | ASTM D6913, ISO 13319, USP <788>, FDA 21 CFR Part 11, GLP/GMP-ready |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Navios EX |
| Technology Platform | Spectral Flow Cytometry |
| Instrument Type | Clinical-Grade Flow Cytometer |
| Laser Configuration | Up to 3 Lasers |
| Detection Channels | 12 |
| Forward Scatter (FSC) Collection Modes | Wide (1–18°), Narrow (1–8°), Wide Enhanced (optimized for submicron particles) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Navios |
| Product Category | Flow Cytometry Analyzer |
| Intended Use | Clinical Diagnostics |
| Lasers | 405 nm (violet), 488 nm (blue), 638 nm (red) |
| Detection Channels | Up to 10-color capability |
| Fluorescence Sensitivity | <112 MESF (FITC), <78 MESF (PE), <15 MESF (PC5) |
| Forward & Side Scatter Detection | Photodiode-based FSC/SSC |
| Fluorescence Detection | Photomultiplier Tube (PMT)-based |
| Optical System | Solid-state diode lasers with integrated flow cell |
| Flow Cell Dimensions | 150 µm × 460 µm rectangular quartz cuvette |
| Temperature Control | Integrated thermal regulation for optical path stability |
| Data Processing | Real-time digital signal processing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Regulatory Certification | China NMPA Import Registration No. 20172401770 |
| Compliance | Designed for CLIA- and CAP-aligned clinical laboratories |