Beckman Coulter
Filter
Showing 61–77 of 77 results
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Imported Instrument |
| Model | OPTIMA AUC |
| Detection Range | 5 µg/mL – 150 mg/mL |
| Sample Volume | 380 µL |
| Analysis Duration | Hours (typically 2–8 h per run) |
| Temperature Control Range | 0–40 °C |
| Detection Modes | UV-Vis Absorbance (190–800 nm) and Interference Optics |
| Simultaneous Wavelengths | Up to 20 |
| Maximum Rotor Capacity | 8 cells (An-50 Ti rotor) |
| Throughput | Up to 7 samples per run (standard configuration), up to 21 sample conditions via sequential or multi-temperature protocols |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Optima MAX-TL |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Ultracentrifuge (>30,000 rpm) |
| Function | General-purpose ultracentrifugation |
| Configuration | Horizontal rotor compatible |
| Separation Level | Cellular and bacterial subfractionation |
| Maximum Capacity | 40.8 mL |
| Maximum Speed | 120,000 rpm |
| Maximum RCF | 657,000 × g |
| Dimensions (W × D × H) | 73.9 × 61.7 × 39.4 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Desktop Ultracentrifuge |
| Speed Range | Up to 120,000 rpm |
| Maximum RCF | 657,400 × g |
| Maximum Capacity | 8 × 5.1 mL |
| Refrigeration | Yes (Cryogenic Cooling) |
| Rotor Compatibility | Full backward compatibility with Optima TL-series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Safety Certification | BioSafe-compliant design |
| Display | Full-color LCD touchscreen with multilingual UI (including Chinese and English) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-TL |
| Instrument Type | Tabletop Centrifuge |
| Speed Range | Up to 120,000 rpm |
| Max RCF | 657,000 × g |
| Max Capacity | 6 × 85 mL |
| Dimensions (W×D×H) | 61.7 × 73.9 × 34.5 cm |
| Rotors Compatibility | Full interchangeability with Optima TL series rotors (fixed-angle, swinging-bucket, vertical, near-vertical) |
| Safety Features | Integrated HEPA filtration, biosafety-certified rotors and tubes |
| Display | Touchscreen LCD with bilingual (English/Chinese) UI support |
| Application Scope | Subcellular fractionation, virus purification, lipoprotein isolation, macromolecular sedimentation |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Benchtop Ultracentrifuge |
| Speed Range | Up to 150,000 rpm |
| Max RCF | 1,019,400 × g |
| Max Capacity | 194.4 mL |
| Sample Volume Range | 0.175–194.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Compliance | Designed for GLP/GMP environments with electronic audit trail support |
| Rotor Types | Fixed-angle, swinging-bucket, vertical, near-vertical |
| Safety | Integrated biosafety features including optional HEPA aerosol containment |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Optima MAX-XP |
| Centrifuge Type | Benchtop Ultracentrifuge |
| Maximum Speed | 150,000 rpm |
| Maximum RCF | 1,019,000 × g |
| Maximum Capacity | 6 × 32.4 mL |
| Dimensions (W × H × D) | 58.4 × 73.7 × 40.9 cm |
| Sample Volume Range | 0.175–194 mL |
| Operating Temperature Range | 0–40 °C |
| Noise Level | <55 dBA (typical at 150,000 rpm) |
| Interface Language | English / Chinese selectable |
| Security Compliance | User authentication, electronic audit trail, FDA 21 CFR Part 11–ready software architecture |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 rpm |
| Max RCF | 802,400 / 694,000 × g |
| Max Capacity | 1.5 L |
| Temperature Range | 0–40 °C (1 °C increment) |
| Temp Accuracy | ±0.5 °C |
| Acceleration Profiles | 10 selectable |
| Deceleration Profiles | 11 selectable (including coast-down) |
| Speed Control Resolution | ±2.00 rpm (≥1,000 rpm) |
| Runtime | up to 999 h 59 min |
| Noise Level | <51 dBA |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, ISO 13485 certified, GLP/GMP-compatible design |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Drive System | Refrigerated Brushless Induction Motor |
| Temperature Control | 0–40 °C (±0.5 °C) |
| Power Supply | 180–264 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Acoustic Noise Level | <51 dBA |
| Standby Power Consumption | <60 W |
| Compliance | ISO 13485, IEC 61010-1, FDA 21 CFR Part 11 (software-enabled audit trail), GLP/GMP-ready configuration options |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Optima XPN |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Class | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Primary Function | Analytical & Preparative Ultracentrifugation |
| Typical Configuration | Fixed-angle Rotor System |
| Separation Target | Subcellular Organelles, Viruses, Macromolecular Complexes |
| Maximum Capacity | 1.5 L |
| Max Speed Options | 100,000 / 90,000 / 80,000 rpm |
| Max RCF | 802,000 × g / 694,000 × g / 548,300 × g |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Floor-standing ultracentrifuge |
| Speed Range | 100,000 / 90,000 / 80,000 rpm |
| Maximum RCF | 802,000 / 694,000 / 548,300 × g |
| Maximum Capacity | 1.5 L |
| Rotor Compatibility | Fixed-angle, swinging-bucket, vertical, near-vertical, and zonal rotors |
| Dimensions (W × D × H) | 94 × 68.1 × 125.7 cm |
| Safety Compliance | Meets IEC 61010-1, UL 61010-1, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vi-CELL BLU |
| Assay Time | Fast Mode 80 s/sample, Standard Mode 110 s/sample |
| Cell Concentration Range | 2 × 10⁴ to 1.5 × 10⁷ cells/mL |
| Sample Volume | Fast Mode 170 µL, Standard Mode 200 µL |
| Throughput | 96 samples per run |
| Detectable Cell Size | 2–60 µm |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Vi-CELL MetaFLEX |
| Pricing | Available Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Model | Vi-CELL XR |
| Origin | USA |
| Product Type | Automated Cell Viability and Counting System |
| Sample Volume Range | 0.5–100 µL |
| Cell Size Detection Range | 2–700 µm |
| Imaging Sensor | 1394 × 1040 CCD array |
| Interface | IEEE 1394 (FireWire) |
| Focus Mechanism | Motorized Auto-Focus |
| Reagent Kits Available | Vi-CELL XR Quad Pack, Vi-CELL AS/S Quad Pack |
| Calibration Standards | Vi-CELL Concentration Control, Vi-CELL Focus Control |
| Data Export Format | Native Excel (.xlsx), CSV, TIFF image archives |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China (Manufactured under Beckman Coulter’s global quality system) |
| Type | Analytical Flow Cytometer |
| Laser Configuration | 1–3 lasers (violet 405 nm, blue 488 nm, red 638 nm) |
| Detection Channels | Up to 13 parameters (including FSC, SSC, and fluorescence) |
| Optical Resolution | rCV < 3% across all channels |
| side scatter resolution | < 300 nm (488 nm laser), < 80 nm (405 nm laser) vs. polystyrene beads |
| Flow Rate | Fixed settings at 10, 30, and 60 µL/min |
| user-defined range | 10–240 µL/min |
| Fluorescence Sensitivity | ≤30 MESF (FITC), ≤10 MESF (PE) at 15-parameter configuration |
| Throughput | Up to 30,000 events per second (EPS) |
| Automation | Integrated autosampler with plate loader (96-/384-well compatible) |
| Compensation | Real-time automated compensation (spillover matrix-based) |
| Sorting Capability | Optional integrated cell sorting module (12-way sorting) |
| Voltage Control | User-adjustable PMT voltage per detector |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CytoFLEX SRT |
| Price Range | USD $15,000–$120,000 (FOB) |
| Technology Platform | Sorting Flow Cytometry |
| Product Type | High-Performance Benchtop Flow Cytometer with Integrated Cell Sorting |
| Intended Use | Research-Only |
| Sample Delivery Rate | 10–100 µL/s (continuously adjustable) |
| Sorting Output | 4-way electrostatic sorting |
| Voltage Adjustment Required | Yes |
| Optical Configuration | V-B-Y-R (Violet-Blue-Yellow-Green-Red) up to 15 fluorescence detectors |
| Biosafety Options | Optional aerosol containment system compatible with Class II biological safety cabinets |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Kaluza |
| Product Type | Flow Cytometry Data Analysis Software |
| Intended Use | Research-Grade Flow Cytometry Data Processing |
| Minimum Display Resolution | 1440×900 |
| File Format Support | FCS 2.0/3.0/3.1, LMD |
| Operating System | Windows 7 (64-bit) and later |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer | Beckman Coulter, Inc. |
| Product Type | Optical Airborne Particle Counter System |
| Model | MET ONE FMS |
| Instrument Category | Optical Particle Counter |
| Compliance | ISO 14644-1, ISO 21501-4, FDA 21 CFR Part 11, EU GMP Annex 1 |