Bioer
Filter
Showing 31–47 of 47 results
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | MB-202 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤ 12 min (varies by block) |
| Oscillation Frequency | 300–3000 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 s – 99 h 59 min |
| Power Input | AC 100–240 V, 50/60 Hz, 180 W |
| Dimensions (L×W×H) | 310 × 210 × 145 mm |
| Net Weight | 5.9 kg |
| Block Recognition | Auto-detect (9 standard blocks included) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | MB-202 |
| Temperature Range | 0°C to 100°C (0.1°C resolution) |
| Temperature Accuracy | ≤ ±0.5°C (15°C–100°C) |
| Temperature Uniformity | ≤ ±0.5°C (20°C–45°C) |
| Shaking Speed | 300–3000 rpm |
| Orbital Amplitude | 3 mm |
| Timer Range | 1 s to 99 h 59 min |
| Power Input | 100–240 V AC, 50/60 Hz, 180 W |
| Dimensions (L×H×W) | 310 × 210 × 145 mm |
| Net Weight | 5.9 kg (host only) |
| Standard Blocks | A (384-well), B (96×0.2 mL skirted/unskirted), C (54×0.5 mL), D (35×1.5 mL), E (35×2.0 mL), F (12×5.0 mL), G (12×15 mL), H (4×50 mL), J (32×0.2 mL + 20×1.5 mL) |
| Brand | Bioer |
|---|---|
| Model | Mini Run |
| Type | Horizontal Electrophoresis Apparatus |
| Power Input | AC 100–110 V, 50–60 Hz or AC 220 V, 50 Hz (with included step-down transformer) |
| Output | DC 50 V / DC 100 V |
| Electrophoresis Chamber Volume | 250 mL (dual-chamber design) |
| Dimensions (L×W×H) | 192 × 130 × 60 mm |
| Net Weight | 320 g |
| Gel Tray Configurations | Four 60 × 55 mm slots or two 110 × 55 mm slots |
| Comb Specifications | 4 × 1 mm × 8 teeth |
| Electrode Material | Platinum-coated stainless steel |
| Housing & Lid Material | Corrosion-resistant engineering thermoplastic |
| Compatible Gels | Agarose and polyacrylamide gels |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Bioer |
|---|---|
| Model | N3-8 |
| Type | Non-Circulating Heating Water Bath |
| Capacity | 8 L |
| Temperature Range | Ambient ±5°C to 99.9°C |
| Temperature Stability | ±0.2°C at 37°C |
| Display | LED Digital |
| Power Supply | AC 220–240 V, 50/60 Hz, 600 W |
| Internal Chamber Dimensions | 325 × 265 × 150 mm (L×W×H) |
| External Dimensions | 445 × 285 × 316 mm (L×W×H) |
| Safety Features | Low-Water-Level Protection, Over-Temperature Cut-Off, Compressor Overload Protection (for models with optional cooling), Current Overload Protection |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (TC-XP-E), 48×2 dual-block (TC-XP-D), 384-well (TC-XP-F), or 4-slide in situ hybridization platform (TC-XP-H) |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Uniformity | ±0.4 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Control Range | 4–99.9 °C |
| Dimensions (L×W×H) | 470 × 340 × 260 mm |
| Net Weight | 10 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-16H |
| Extraction Method | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 16 Samples per Run |
| Sample Volume Range | 50–10,000 µL |
| Consumables | Individual Tubes + Magnetic Rod Array Cartridge |
| Oscillation Mode | Multi-Mode, Multi-Stage Adjustable |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 29.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-32E |
| Principle | Magnetic bead-based separation |
| Automation Level | Dedicated fully automated platform |
| Sample Throughput | 1–32 samples per run |
| Processing Time | As fast as 8 minutes per batch |
| Heating Capacity | Deep-well heating block with programmable lysis/elution temperature control (ambient to 95 °C) |
| Magnet Type | Permanent magnet rod array with dynamically adjustable oscillation amplitude |
| Sample Plate Compatibility | 2.2 mL 96-well deep-well plates |
| Interface | USB port for protocol transfer and system update |
| Oscillation Mode | Vertical reciprocating motion |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 28.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 350 W |
| Safety Features | Interlocked door sensor, built-in UV-C germicidal lamp (254 nm), aerosol-resistant sealing design |
| Modular Expandability | Optional 48-well adapter module available |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-96 |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 8–15 minutes |
| Compatible Plate Format | 96-well deep-well plates (2.2 mL) |
| Interface | USB, LAN |
| Operating System Support | Windows 7 / 8.1 / 10 |
| Dimensions (L×W×H) | 907 × 495 × 571 mm |
| Net Weight | 81.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 1000 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-96E |
| Extraction Method | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 96 |
| Compatible Plate Format | 2.2 mL 96-well Deep-Well Plate |
| Heating/Cooling | Integrated Heated and Cooled Elution Station (4–105 °C) |
| Oscillation Mode | Vertical Vibration |
| Dimensions (L×W×H) | 820 × 492 × 564 mm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, 800 W |
| Interface | USB |
| HEPA Filtration | Yes |
| UV Sterilization | Built-in |
| Safety Features | Interlocked Door Sensor, Drip-Proof Partition, Real-Time Contamination Monitoring |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPAs-9600 |
| Instrument Type | Magnetic Bead-Based Automation |
| Throughput | 96 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time (96 samples) | ≤30 min |
| Power Supply | AC 220 V, 50 Hz, 1500 VA |
| Dimensions (L×W×H) | 1400 × 700 × 1980 mm |
| Sample Compatibility | Whole blood, swabs, urine, animal/plant tissues |
| Input Vessel Types | Cryovials, microcentrifuge tubes, collection tubes |
| Integrated Functions | Sample aliquoting, magnetic bead-based nucleic acid purification, and PCR master mix dispensing |
| Contamination Control | UV sterilization, HEPA-filtered laminar airflow, droplet capture technology |
| Human-Machine Interface | Full-color capacitive touchscreen with intuitive GUI |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥3.0 °C/s |
| Temperature Accuracy | ≤±0.3 °C |
| Well-to-Well Temperature Uniformity | ≤±0.4 °C at 95 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-EA |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48-well (dual-format), 4-slide in situ hybridization module |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Range | 4–105 °C |
| Dimensions (L×W×H) | 368 × 250 × 285 mm |
| Net Weight | 10.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-EA-B-96GA |
| Temperature Range | 4–99 °C |
| Communication Interfaces | USB, RJ45 |
| Input Power | 100–240 V AC, 50–60 Hz (1000 W) |
| Module Dimensions | 156.5 × 253 × 125.8 mm |
| Host Dimensions | 256.5 × 414.5 × 65 mm |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | HB-202 |
| Temperature Range | 10–105°C |
| Temperature Accuracy | ≤ ±0.5°C |
| Heating Time | ≤12 min (20°C → 100°C) |
| Dimensions (L×W×H) | 300 × 200 × 160 mm |
| Net Weight | 2.8 kg |
| Power Supply | 220 V~, 50 Hz, 120 W |
| Temperature Uniformity Across Block | ≤ ±0.5°C |
| Timer Range | 1 min – 99 h 59 min |
| Cooling Method | Peltier (TE) element |
| Heating Method | Resistive heating element |
| Standard Block Configurations | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate), E (115 × 73 × 38 mm water bath insert) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | MB-102 |
| Temperature Range | 0°C to 100°C (with active cooling down to ambient −14°C) |
| Temperature Accuracy | ≤ ±0.5°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Heating Time | ≤12 min (20°C → 100°C) |
| Cooling Rate | ≥6°C/min (100°C → ambient), ≥0.8°C/min (ambient → −10°C) |
| Cooling Time | ≤8 min (ambient → −10°C), ≤15 min (100°C → ambient +10°C) |
| Oscillation Speed | 300–1500 rpm |
| Oscillation Amplitude | 3 mm |
| Timer Range | 1 min – 99 h 59 min |
| Dimensions (L×W×H) | 328 × 249 × 166 mm |
| Net Weight | 8.5 kg |
| Power Supply | AC 220 V ±22 V, 150 W, 50 ±1 Hz |
| Standard Blocks | A (40 × 1.5 mL), B (54 × 0.5 mL), C (96 × 0.2 mL), D (24 × φ15 mm), H (40 × 2.0 mL), G (26 × 0.5 mL + 24 × 1.5 mL), J (96-well microplate) |
| Brand | Bioer |
|---|---|
| Model | HB-T1 |
| Type | Programmable Metal Block Heater |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.2°C |
| Temperature Uniformity | ≤±0.5°C |
| Temperature Stability (Fluctuation) | ≤±0.1°C |
| Temperature Resolution | 0.1°C |
| Heating Time | ≤10 min (from 20°C to 100°C) |
| Cooling Time | ≤8 min (from 100°C to 4°C) |
| Programmable Timer | 0–99 h 59 min or ∞ |
| Max. Program Steps | 9 |
| Max. Cycles | 99 |
| Heat Lid Temp | ≥ Block Temp +10°C (disabled if block <15°C) |
| Heat Lid Heating Time | ≤10 min (to 110°C) |
| Heat Lid Design | Removable, pressure-capable without heating element |
| Power Supply | AC 100–220 V, 50–60 Hz (via universal 24 V DC adapter) |
| Interface | USB-B for PC connectivity |
| Display | 3-digit LED |
| Status Indication | Tri-color LED (red = heating, yellow = holding, green = cooling) |
| Safety Features | Dual independent over-temperature protection (block & heat lid), sensor fault buzzer alarm |
| Dimensions (L×W×H) | 150 × 170 × 145 mm |
| Net Weight | ≤1.8 kg (varies by module) |
| Brand | Bioer |
|---|---|
| Model Series | HB-T1, HB-T2, CHB-T1, CHB-T2 |
| Temperature Range | 0°C to 100°C (model-dependent) |
| Temperature Accuracy | ≤ ±0.2°C |
| Heating Time | ≤ 8 min (20°C → 100°C) |
| Dimensions | 150 × 170 × 145 mm (L × W × H) |
| Net Weight | ≤ 2.0 kg |
| Power Input | HB/CHB-T1 & T2: AC 100–240 V, 50/60 Hz |
| Timer Range | 0–99 h 59 min |
| Max Program Steps | 9 |
| Max Cycles per Program | 99 |
| Standard Block Modules | A (20 × 0.5 mL), B (35 × 1.5 mL), C (54 × 0.5 mL), D (96 × 0.2 mL), E (35 × 2.0 mL) |