BOXUN
Filter
Showing 1–30 of 70 results
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BC-J160S / BC-J80S |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Input Power | 550 W |
| Heating Method | Water-jacketed |
| Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Stability (at 37 °C) | ≤ ±0.1 °C |
| CO₂ Range | 0–20% (v/v) |
| CO₂ Control | Infrared (IR) sensor, accuracy ±0.1% |
| CO₂ Recovery Time | ≤ concentration value × 1.2 min |
| Humidification | Natural evaporation |
| Chamber Volume | 160 L / 80 L |
| Interior Dimensions (W×D×H) | 550 × 500 × 650 mm |
| Exterior Dimensions (W×D×H) | 700 × 620 × 980 mm |
| Shelving | 3 adjustable stainless-steel shelves |
| Filtration | HEPA-grade filter, ≥99.998% efficiency for particles ≥0.3 µm |
| Interface | RS-485 port with PC connectivity and included data logging software |
| Safety Features | Dual independent temperature control circuits, UV sterilization lamp, door-heating anti-condensation system, power-failure parameter retention and auto-recovery |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BC-J80 (Gas-Jacketed, TCD-based CO₂ Control) |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Fluctuation | ≤ ±0.2°C |
| Temperature Resolution | 0.1°C |
| CO₂ Range | 0–19.9% |
| CO₂ Control Method | Thermal Conductivity Detector (TCD) |
| CO₂ Recovery Time | ≤ (setpoint %) × 2 minutes |
| Chamber Volume | 80 L (nominal) |
| Internal Dimensions (W×D×H) | 420 × 400 × 550 mm |
| External Dimensions (W×D×H) | 580 × 560 × 900 mm |
| Shelf Capacity | 2 adjustable stainless-steel shelves |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Rated Power | 700 W |
| Humidification Method | Natural Evaporation |
| Filtration Efficiency | ≥99.998% for particles ≥0.3 µm (dual-stage HEPA filtration) |
| Sterilization Mode | 90°C high-humidity thermal decontamination |
| Interface | RS-485 for PC/data logger connectivity |
| Backup Function | Parameter memory with power-fail recovery |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | BG-160 |
| Price Range | USD 700–1,400 (FOB) |
| Temperature Control Range | Ambient +2°C to 65°C |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.5°C |
| Heating Method | Water-Jacketed |
| Power Input | 1030 W |
| Interior Dimensions (W×D×H) | 550 × 500 × 650 mm |
| Exterior Dimensions (W×D×H) | 700 × 630 × 965 mm |
| Shelving | 3 Adjustable Stainless Steel Trays |
| Display | LCD with Microprocessor-Based Controller |
| Communication Interface | RS-485 |
| Programmability | 10 segments × 100 cycles |
| Data Protection | Power-Fail Memory & Auto-Restart Function |
| Optional Accessories | Thermal Printer (curve logging), GPRS Remote Alarm Module, PC Monitoring Software |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BG-270 |
| Price Range | USD 700–1,400 (FOB) |
| Temperature Range | Ambient +2°C to 65°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C |
| Temperature Fluctuation | ±0.2°C |
| Heating Method | Water-Jacketed |
| Power Input | 1530 W |
| Inner Chamber Dimensions (W×D×H) | 600 × 600 × 750 mm |
| External Dimensions (W×D×H) | 750 × 730 × 1065 mm |
| Shelf Capacity | 3 Adjustable Stainless Steel Shelves |
| Control Interface | LCD with Microprocessor-Based PID Controller |
| Programmability | 10 segments × 100 cycles |
| Communication | RS-485 port for PC/data logger integration |
| Safety Features | Over-Temperature Alarm, Auto-Restart after Power Recovery, Parameter Memory Retention |
| Optional Accessories | Thermal Printer (curve logging), GPRS Remote Alert Module, PC Monitoring Software |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | BG-80 |
| Price Range | USD 140–700 (FOB) |
| Temperature Control Range | Ambient +2°C to 65°C |
| Temperature Resolution | 0.1°C |
| Temperature Fluctuation | ±0.2°C |
| Temperature Uniformity | ±0.5°C |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Heating Method | Water-jacketed |
| Input Power | 630 W |
| Inner Chamber Dimensions (W×D×H) | 400 × 400 × 500 mm |
| External Dimensions (W×D×H) | 550 × 530 × 815 mm |
| Shelf Capacity | 2 adjustable stainless steel shelves |
| Interface | RS-485 for external data logging or PC connectivity |
| Programmable Cycle | Up to 10 segments × 100 cycles |
| Backup Function | Power-loss parameter retention with auto-recovery |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BGZ-146 / BGZ-246 |
| Display Type | LCD Upgrade Version |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Temperature Range | Ambient +5 °C to 300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Input Power | 2000 W |
| Interior Dimensions (W×D×H) | 550 × 500 × 550 mm |
| Exterior Dimensions (W×D×H) | 840 × 625 × 780 mm |
| Shelving | 3 adjustable stainless-steel shelves |
| Timer Range | 0–99 h 60 min |
| Interface | RS-485 for PC/data logger connectivity |
| Construction | Cold-rolled steel exterior with eco-friendly metallic paint |
| Air Circulation | Precision-engineered forced-air system with imported motor and impeller |
| Safety Features | Power-loss parameter retention and auto-recovery, over-temperature alarm, real-time monitoring capability |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BGZ-240 |
| Price Range | USD 700–1,150 (FOB) |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | Ambient +5°C to 250°C |
| Temperature Uniformity | ±2% (at setpoint) |
| External Dimensions (W×D×H) | 890 × 745 × 905 mm |
| Internal Chamber Dimensions (W×D×H) | 600 × 520 × 750 mm |
| Chamber Material | Mirror-Finish Stainless Steel (SUS304) |
| Heating Method | Forced-Air Circulation with Adjustable Fan Speed (6-step) |
| Control Resolution | 0.1°C |
| Temperature Stability | ±1°C at 100°C |
| Rated Power | 2150 W |
| Chamber Volume | 234 L |
| Standard Shelves | 3 pcs (max. 10 pcs) |
| Shelf Load Capacity | 15 kg per shelf |
| Timer Range | 0–9999 min/h |
| Delay Start Range | 0–999 min |
| Programmable Stages | 10 segments × 100 cycles |
| Interface | RS-485 for PC connectivity |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Recovery Function | Auto-restart with parameter retention after power interruption |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-1CD / BJ-2CD |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100 @ ≥0.5 µm) |
| Adjustable Air Velocity Range | 0.1–0.6 m/s |
| Noise Level | ≤62 dB(A) |
| Illuminance | ≥300 lx |
| Vibration Half-Peak Amplitude | ≤3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.2 kW (BJ-1CD) / 0.37 kW (BJ-2CD) |
| Net Weight | 115 kg (BJ-1CD) / 205 kg (BJ-2CD) |
| Work Area Dimensions | 830 × 700 × 520 mm (BJ-1CD) / 1300 × 700 × 520 mm (BJ-2CD) |
| External Dimensions | 891 × 725 × 1577 mm (BJ-1CD) / 1460 × 725 × 1577 mm (BJ-2CD) |
| HEPA Filter Specifications | 765 × 548 × 50 mm × 1 (BJ-1CD) / 1236 × 549 × 50 mm × 1 (BJ-2CD), Unibody Pleated HEPA, ≥99.995% @ 0.3 µm |
| Pre-filter | Synthetic Fiber Medium-Efficiency Panel Filter |
| Lighting | 30 W Fluorescent Lamp × 1 + 20 W UV Lamp × 1 (BJ-1CD) / 40 W Fluorescent Lamp × 1 + 30 W UV Lamp × 1 (BJ-2CD) |
| Safety Interlock | UV Lamp & Main Light Interlocked |
| Control Interface | LCD Display with Real-Time Parameters (Air Velocity, Differential Pressure, Cumulative Operating Time, Clock, HEPA Status) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-1CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Working Surface Dimensions (W×D×H) | 830 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 990 × 744 × 1680 mm |
| HEPA Filter Specification | 800 × 604 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Fan Type | High-efficiency centrifugal blower |
| Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Illumination | ≥300 lx (30 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.2 kW |
| Net Weight | 115 kg |
| Work Surface Material | SUS304 brushed stainless steel |
| Cabinet Material | Cold-rolled steel with epoxy-powder coating |
| Control Interface | LCD display with multi-parameter monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BJ-2CD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-Operator, Single-Face Configuration |
| Airflow Pattern | Vertical Unidirectional Flow |
| Working Surface Dimensions | 1300 × 700 × 495 mm (W × D × H) |
| Overall Dimensions | 1460 × 744 × 1680 mm (W × D × H) |
| HEPA Filter Specification | 1270 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 40 W) |
| UV Lamp | 30 W, germicidal |
| Vibration Amplitude | ≤5 µm (peak-to-peak, X/Y/Z axes) |
| Adjustable Air Velocity Range | 0.3–0.6 m/s (6-step digital setpoint with real-time display) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.37 kW |
| Net Weight | 205 kg |
| Control Interface | LCD panel with multi-parameter real-time monitoring |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BJ-3CD |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| Airflow Pattern | Vertical Downflow |
| Rated User Capacity | Three-person, single-sided operation |
| Working Surface Dimensions (W×D×H) | 1800 × 700 × 495 mm |
| Overall Dimensions (W×D×H) | 1960 × 744 × 1680 mm |
| HEPA Filter Specification | 1770 × 604 × 50 mm, single unit |
| Illumination | ≥300 lux (fluorescent lamp, 30 W × 2) |
| UV Lamp | 30 W × 1 |
| Average Air Velocity Range | 0.3–0.6 m/s (6-step adjustable, real-time digital display) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 0.55 kW |
| Net Weight | 280 kg |
| Construction Materials | Cold-rolled steel housing |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BSC-1000A2 |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1220 × 860 × 2225 mm |
| Internal Dimensions (L×W×H) | 1100 × 500 × 640 mm |
| Filter Efficiency (for 0.3 µm particles) | ≥99.99% |
| Inflow Velocity | 0.55 m/s ± 0.02 m/s |
| Downflow Velocity | 0.35 m/s ± 0.02 m/s |
| Airflow Pattern | 70% recirculated, 30% exhausted |
| Work Area Classification | ISO 5 (equivalent to US FED STD 209E Class 100) |
| Personnel Protection Factor (KI test) | ≥1 × 10⁵ |
| Product Protection (colony count) | ≤5 CFU/test |
| Cross-Contamination Protection (impactor sampling) | ≤2 CFU/test |
| Noise Level | ≤67 dB(A) |
| Vibration Peak-to-Peak | ≤5 µm |
| Illumination | ≥650 lux |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤70% at 25 °C |
| Ambient Pressure Range | 80–105 kPa |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Total Power Consumption | 1.25 kW (including integrated AC outlets) |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BSC-1000B2 |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1120 × 895 × 2340 mm |
| Internal Work Area Dimensions (L×W×H) | 1000 × 500 × 640 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm |
| Inflow Velocity | 0.55 m/s |
| Downflow Velocity | 0.35 m/s |
| Downflow Control Accuracy | ±0.015 m/s |
| Pressure Differential Range | 0–500 Pa |
| Noise Level | ≤67 dB(A) |
| Vibration Peak-to-Peak | ≤5 µm |
| Average Illuminance | ≥650 lx |
| Operating Ambient Temperature | 10–30 °C |
| Relative Humidity | ≤70% (at 25 °C) |
| Atmospheric Pressure Range | 80–105 kPa |
| Lighting | 2 × 30 W fluorescent lamps + 1 × 18 W UV lamp |
| Power Consumption | 2.1 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BSC-1360A2 |
| Instrument Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1420 × 860 × 2225 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 500 × 640 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm |
| Inflow Velocity | 0.55 m/s ±0.02 m/s |
| Downflow Velocity | 0.35 m/s ±0.02 m/s |
| Air Recirculation Ratio | 70% |
| Exhaust Ratio | 30% |
| Noise Level | ≤67 dB(A) |
| Vibration Peak-to-Peak | ≤5 µm |
| Average Illuminance | ≥650 lux |
| Operating Temperature Range | 10–30 °C |
| Relative Humidity Limit | ≤70% @ 25 °C |
| Atmospheric Pressure Range | 80–105 kPa |
| Personnel Protection Factor (KI Test) | ≥1×10⁵ |
| Product Protection (Settle Plate) | ≤5 CFU/plate/test |
| Cross-Contamination Protection (Impactor Sampler) | ≤2 CFU/plate/test |
| Lighting & UV Lamp | 30 W × 1 each |
| Total Power Consumption | 1.4 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BSC-1360B2 |
| Instrument Type | Class II Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1420 × 895 × 2340 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 500 × 640 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm |
| Inflow Velocity | 0.55 m/s |
| Downflow Velocity | 0.33 m/s |
| Downflow Control Accuracy | ±0.015 m/s |
| Pressure Differential Range | 0–500 Pa |
| Noise Level | ≤67 dB(A) |
| Vibration Half-Peak | ≤5 µm |
| Average Illuminance | ≥650 lx |
| Operating Ambient Temperature | 10–30 °C |
| Relative Humidity | ≤70% @ 25 °C |
| Atmospheric Pressure Range | 80–105 kPa |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Total Power Consumption | 2.2 kW |
| Lighting | 2 × 40 W fluorescent lamps + 1 × 30 W UV lamp |
| Supply Filter Size | 1326 × 606 × 70 mm |
| Exhaust Filter Size | 782 × 515 × 90 mm |
| Work Surface | Removable SUS304 stainless steel with integrated liquid collection trough and drain valve |
| Airflow Sensors | Imported U.S.-made constant-velocity anemometers |
| Fan System | EBMPAPST (Germany) centrifugal blowers |
| Safety Interlocks | UV/light interlock, sash position alarm, fan shutdown at sash closure |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | BSD-YX(F)3400 |
| Price Range | USD 2,800–7,000 (est.) |
| Instrument Type | Full-Temperature Oscillator / Shaker |
| Timer Range | 0–999 h |
| Oscillation Frequency | Orbital 30–300 rpm, Reciprocating 30–250 rpm |
| Oscillation Amplitude | Orbital Ø26 mm, Reciprocating 0–50 mm |
| Temperature Range | RT+8°C to 60°C |
| Shelf Quantity | 2 shelves |
| Brand | BOXUN |
|---|---|
| Model | BXG-1000 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Control Temperature Range (Dark) | 0–70°C |
| Control Temperature Range (Illuminated) | 10–70°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity (at 25°C) | ±2°C |
| Temperature Fluctuation (at 25°C) | ±0.5°C |
| Illuminance Range | 0–30,000 lux (10-step adjustable) |
| Internal Chamber Dimensions (L×W×H) | 1363×670×1123 mm |
| External Dimensions (L×W×H) | 1505×1006×1811 mm |
| Standard Shelving | 4 stainless steel shelves (max. 12) |
| Standard Light Panels | 4 multi-spectrum LED or fluorescent light panels (max. 6) |
| Input Power (Standard) | 3350 W |
| Input Power (Humidity-Enabled Variant) | 3950 W |
| Programming Capacity | 30 segments × 99 cycles |
| Data Logging Capacity | 250,000 records |
| Real-time Log View | Last 1600 temperature entries |
| Interface | USB 2.0, RS485 |
| Compliance Options | FDA 21 CFR Part 11–compliant software (optional), GMP/GLP audit trail enabled (optional) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-100 |
| Price Range | USD 2,100 – 4,200 (est.) |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.5°C |
| External Dimensions (W×D×H) | 620 × 640 × 1165 mm |
| Internal Chamber Dimensions (W×D×H) | 450 × 500 × 450 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Heated Shelf System with Independent Zone Control |
| Vacuum Level | ≤133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 100 L |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power | 1400 W |
| Timer Range | 0–9999 min |
| Shelving | 2 adjustable heated shelves with individual temperature monitoring and control |
| Noise Reduction | Integrated acoustic enclosure for vacuum pump (−40 dB(A) vs. external pump setup) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXK-250S |
| Instrument Type | Vacuum Oven |
| Temperature Range | Ambient +2°C to 250°C |
| Temperature Uniformity | ±0.3°C |
| External Dimensions (W×D×H) | 770×780×1515 mm |
| Internal Chamber Dimensions (W×D×H) | 600×600×700 mm |
| Chamber Material | Stainless Steel |
| Heating Method | Shelf-Mounted Heaters with Forced Convection |
| Vacuum Level | 133 Pa |
| Pump Flow Rate | 2 L/s |
| Chamber Volume | 250 L |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Rated Power | 2200 W |
| Timer Range | 0–9999 min |
| Number of Adjustable Shelves | 3 (Individually Temperature-Controlled) |
| Display | LCD Microprocessor Controller |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-100M |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 870 mm |
| External Dimensions | 750 × 800 × 1180 mm |
| Chamber Volume | 100 L |
| Heating Power | 6.8 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-110FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 585 × 750 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temp Range | 80–130 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Drying Duration | 10–6000 min |
| Power Input | 5.4 kW |
| Voltage | 220 V ± 10 %, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80 % RH |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-110VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 835 mm |
| External Dimensions | 535 × 640 × 1275 mm |
| Chamber Volume | 110 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Temp Range | 105–135 °C |
| Melting Temp Range | 50–100 °C |
| Holding Temp Range | 40–60 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Melting/Holding Time Range | 0–6000 min |
| 预约 Function | Up to 100 h |
| Heating Power | 3.5 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Operating Ambient | 5–40 °C, 20–80% RH |
| Cooling System | Standard air-cooling + secondary water-cooling + condenser |
| Safety Protections | Overtemperature shutdown, low-water cutoff, overpressure mechanical relief, independent electronic overpressure sensor, anti-scald insulation, overload protection, short-circuit protection, earth leakage protection |
| User Access Levels | Engineer / Administrator / Operator (3-tier permission management) |
| Interface | Capacitive touchscreen, RS-485 ×2, G1/2A calibration port, waterproof socket ×1 |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-120M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 740 mm |
| External Dimensions | 850 × 910 × 1080 mm |
| Chamber Volume | 120 L |
| Temperature Range (Sterilization) | 105–135°C |
| Temperature Range (Drying) | 102°C |
| Temperature Range (Melting) | 40–100°C |
| Temperature Range (Heating/Insulation) | 25–85°C |
| Time Range (Sterilization) | 4–120 min |
| Time Range (Drying/Melting/Insulation) | 0–999 min |
| Pre-set Delay | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Efficiency | <1% residual moisture |
| Heating Power | 9.9 kW |
| Power Supply | ~380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air cooling with built-in fan |
| Air Intake Filtration | Integrated HEPA-grade air filter |
| Dual Water Inlet System | Selectable pure water or tap water supply |
| Standard Sample Temperature Probe | Real-time monitoring of load temperature |
| C.W.S. Condensate Water Reuse System | Recirculates sterilization condensate |
| W.P.S. Waste Processing System | Filters and purifies exhaust steam and condensate prior to discharge |
| Safety Features | Mechanical self-locking + electronic interlock door mechanism, overtemperature cutoff, independent safety limiter, overpressure auto-relief, fault self-diagnosis, water-level auto-refill |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-150M |
| Instrument Type | Vertical Steam Sterilizer |
| Max Temperature | 135 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø500 × 870 mm |
| External Dimensions | 850 × 910 × 1180 mm |
| Chamber Volume | 150 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp Range | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time Range | 4–120 min |
| Drying Time Range | 0–999 min |
| Melting/Holding Time Range | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 10.5 kW |
| Power Supply | 380 V ±38 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BXM-30R |
| Instrument Type | Vertical |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.14 MPa |
| Chamber Dimensions | Φ300 × 420 mm |
| External Dimensions | 395 × 395 × 780 mm |
| Chamber Volume | 29 L |
| Power Rating | 2 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating/Design Temp. | 126 °C / 128 °C |
| Operating/Design Pressure | 0.14 MPa / 0.165 MPa |
| Timer Range | 0–120 min |
| Basket Dimensions | Φ280 × 340 mm (1 unit) |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-50M |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 520 mm |
| External Dimensions | 750 × 800 × 950 mm |
| Chamber Volume | 50 L |
| Sterilization Temp Range | 105–135 °C |
| Drying Temp | 102 °C |
| Melting Temp Range | 40–100 °C |
| Holding Temp Range | 25–85 °C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.1 kW |
| Supply Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Temp | 5–40 °C |
| Ambient Humidity | 20–80% RH |
| Chamber & Basket Material | SUS304 Stainless Steel |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-60VF |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 150 °C |
| Maximum Working Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 635 mm |
| External Dimensions | 585 × 750 × 1075 mm |
| Chamber Volume | 60 L |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (extendable to 6000 min) |
| Drying Temperature Range | 80–130 °C |
| Melting/Soaking Range | 50–100 °C |
| Holding Range | 40–60 °C |
| Power Input | 4.8 kW |
| Voltage | 220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-75M |
| Instrument Type | Vertical |
| Max Temperature | 135°C |
| Max Working Pressure | 0.22 MPa |
| Chamber Dimensions | Ø400 × 700 mm |
| External Dimensions | 750 × 800 × 1080 mm |
| Chamber Volume | 75 L |
| Sterilization Temp Range | 105–135°C |
| Drying Temp Range | 102°C |
| Melting Temp Range | 40–100°C |
| Holding Temp Range | 25–85°C |
| Sterilization Time | 4–120 min |
| Drying Time | 0–999 min |
| Melting/Holding Time | 0–999 min |
| Delay Start | Up to 99 h 60 min |
| Design Pressure | 0.25 MPa |
| Drying Residual Moisture | <1% |
| Heating Power | 5.9 kW |
| Power Supply | ~220 V ± 22 V, 50 Hz ± 1 Hz |
| Ambient Operating Conditions | 5–40°C, 20–80% RH |
| Chamber & Basket Material | SUS304 stainless steel |
| Cooling Method | Forced-air rapid cooling |
| Air Intake Filtration | Built-in HEPA-grade filter |
| Dual Water Inlet System | Selectable pure water or tap water |
| Condensate Recycling System (C.W.S.) | Integrated |
| Waste Gas & Effluent Purification System (W.P.S.) | Integrated |
| Standard Sample Temperature Probe | Yes |
| Data Logging & Export | Yes |
| Safety Features | Mechanical self-locking + electronic interlock door, overtemperature cutoff, independent safety limiter, overpressure relief valve, fault self-diagnosis |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BXM-85FI |
| Instrument Type | Vertical |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 585 × 750 × 1165 mm |
| Chamber Volume | 85 L |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Model | BXM-85VE |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 150 °C |
| Max Pressure | 0.38 MPa |
| Chamber Dimensions | Ø400 × 725 mm |
| External Dimensions | 535 × 640 × 1165 mm |
| Chamber Volume | 85 L |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | < +1 °C |
| Sterilization Time Range | 0–120 min (customizable up to 6000 min) |
| Power Supply | ~220 V ±22 V, 50 Hz ±1 Hz |
| Ambient Operating Conditions | 5–40 °C, 20–80% RH |