Empowering Scientific Discovery

BOXUN BSC-1360A2 Class II Biological Safety Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BOXUN
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Origin Category Domestic (China)
Model BSC-1360A2
Instrument Type Class II A2 Biological Safety Cabinet
External Dimensions (L×W×H) 1420 × 860 × 2225 mm
Internal Work Area Dimensions (L×W×H) 1300 × 500 × 640 mm
HEPA Filter Efficiency ≥99.99% @ 0.3 µm
Inflow Velocity 0.55 m/s ±0.02 m/s
Downflow Velocity 0.35 m/s ±0.02 m/s
Air Recirculation Ratio 70%
Exhaust Ratio 30%
Noise Level ≤67 dB(A)
Vibration Peak-to-Peak ≤5 µm
Average Illuminance ≥650 lux
Operating Temperature Range 10–30 °C
Relative Humidity Limit ≤70% @ 25 °C
Atmospheric Pressure Range 80–105 kPa
Personnel Protection Factor (KI Test) ≥1×10⁵
Product Protection (Settle Plate) ≤5 CFU/plate/test
Cross-Contamination Protection (Impactor Sampler) ≤2 CFU/plate/test
Lighting & UV Lamp 30 W × 1 each
Total Power Consumption 1.4 kW
Electrical Supply AC 220 V ±10%, 50/60 Hz

Overview

The BOXUN BSC-1360A2 is a certified Class II, Type A2 biological safety cabinet engineered for rigorous containment and personnel protection in biosafety level 2 (BSL-2) laboratories. It operates on the principle of inward laminar airflow combined with downward vertical laminar flow—both conditioned through high-efficiency particulate air (HEPA) filtration—to simultaneously protect the operator, the environment, and the work sample. Designed in accordance with NSF/ANSI 49-2022 and EN 12469:2000 standards, the BSC-1360A2 maintains ISO Class 5 (equivalent to Federal Standard 209E Class 100) cleanliness within its work area. Its dual airflow configuration—70% recirculated and 30% exhausted via dedicated ducting—ensures stable containment during routine microbiological, cell culture, recombinant DNA, and diagnostic procedures without requiring connection to external exhaust infrastructure when used with optional canopy or thimble exhaust adapters.

Key Features

  • Intelligent AirClean Control System featuring a full-color LCD interface displaying real-time inflow/downflow velocity, HEPA filter service life estimation, and status indicators for UV lamp, lighting, fan, and power outlets—with bilingual (English/Chinese) fault alerts and calendar/time synchronization.
  • Programmable UV sterilization scheduling aligned to Gregorian calendar, enabling timed activation/deactivation to minimize ozone exposure and eliminate manual oversight errors.
  • Outlet timer function for auxiliary equipment (e.g., needle incinerators), enhancing operational safety and energy efficiency.
  • Adaptive constant-velocity control using dual high-precision hot-wire anemometers; maintains inflow and downflow stability within ±0.02 m/s even as filter resistance increases by up to 50%, with total airflow deviation <10%.
  • Interlocked UV and fluorescent lighting circuits prevent concurrent operation—eliminating accidental UV exposure during active work.
  • Front sash position monitoring with audible/visual alarms triggered if sash exceeds safe operational limits (typically 180–220 mm), preserving negative pressure integrity and preventing turbulence-induced contamination.
  • ISO 5-grade HEPA filters (≥99.998% @ 0.3 µm) constructed from imported filter media offering low initial pressure drop, high mechanical strength, and extended service life; ULPA (ISO 4) upgrade option available for enhanced particle retention (≥99.9995% @ 0.12 µm).
  • Integrated filter failure detection algorithm that triggers multi-modal alerts (acoustic, visual, on-screen text) upon reaching end-of-life thresholds or detecting physical damage or excessive differential pressure.

Sample Compatibility & Compliance

The BSC-1360A2 accommodates standard BSL-2 workflows involving bacterial cultures (e.g., E. coli, S. aureus), mammalian cell lines, viral vectors (non-aerosol-generating protocols), and clinical specimens. Its work area dimensions (1300 × 500 × 640 mm) support dual-user operation with ergonomic 10° inclined tempered glass sash, anti-glare surface treatment, and seamless SUS304 stainless steel interior with radius-cornered construction for validated cleaning and decontamination. All structural materials comply with ISO 8573-1:2010 for compressed air purity and meet UL 61010-1 requirements for laboratory equipment safety. Certification documentation includes third-party verification per NSF/ANSI 49 Annex D (personnel/product/cross-contamination testing), supporting GLP/GMP-aligned validation protocols and FDA 21 CFR Part 11-compliant audit trails when integrated with BOXUN’s optional data logging module.

Software & Data Management

The embedded AirClean controller logs timestamped operational parameters—including sash height, airflow velocities, filter delta-P, UV runtime, and alarm events—for up to 30 days onboard. Data export is supported via USB port in CSV format, compatible with LIMS integration and electronic lab notebook (ELN) platforms. Optional firmware upgrades enable RS-485 Modbus RTU communication for centralized facility monitoring systems. All critical settings are password-protected with role-based access levels (Operator/Supervisor/Administrator), satisfying ALCOA+ data integrity principles for regulated environments.

Applications

  • Microbiological isolation and subculturing under sterile conditions
  • Mammalian and insect cell passaging, transfection, and cryopreservation
  • Preparation of diagnostic reagents and clinical assay kits
  • Handling of low-risk viral stocks (e.g., lentiviral pseudotypes) in non-high-containment settings
  • Pharmaceutical QC testing involving sterility checks and environmental monitoring sample processing
  • Teaching laboratory applications requiring dual-station ergonomics and robust training safeguards

FAQ

What biosafety level does the BSC-1360A2 support?

It is certified for BSL-2 applications per CDC/NIH guidelines and complies with NSF/ANSI 49 requirements for Class II, Type A2 cabinets.
Is external ducting required for safe operation?

No—recirculating mode enables standalone use; however, hard-ducted exhaust is recommended when working with volatile chemicals or higher-risk agents to maintain optimal containment.
Can the cabinet be validated for GMP compliance?

Yes—its design supports IQ/OQ/PQ execution per ASTM E1952 and ISO 14644-3, with documented test reports available upon request.
What maintenance intervals are recommended for HEPA filters?

Annual integrity testing (DOP/PAO scan) is advised; replacement frequency depends on usage intensity and ambient particulate load, typically every 3–5 years under normal laboratory conditions.
Does the unit support remote monitoring?

With optional RS-485 interface and BOXUN’s FacilityLink software, real-time status and historical logs can be accessed via local network or secure cloud portal.