| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | XZ-151-III |
| Instrument Type | Vacuum Drying Oven |
| Temperature Range | RT+10 to 250°C |
| Temperature Uniformity | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Vacuum Level | ≤133 Pa |
| Internal Chamber Dimensions (W×D×H) | 750×530×380 mm |
| Chamber Material | 304 Stainless Steel |
| Heating Method | External Forced-Air Circulation |
| Operating Ambient Temperature | +5 to +45°C |
| Insulation | Fiberglass Blanket |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | XZ-91-II |
| Instrument Type | Vacuum Drying Oven |
| Temperature Range | RT+10 to 250°C |
| Temperature Fluctuation | ±0.5°C |
| Internal Chamber Dimensions | 450 × 450 × 450 mm |
| Temperature Resolution | 0.1°C |
| Operating Ambient Temperature | 5–45°C |
| Inner Chamber Material | 304 Stainless Steel |
| Heating Method | External (Four-Side) Radiant Heating |
| Temperature Uniformity | ±1°C |
| Ultimate Vacuum Level | ≤133 Pa |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XZD-2500 |
| Operating Mode | Continuous |
| Speed Range | 500–2500 rpm |
| Motion Type | Horizontal Orbital Shaking |
| Amplitude | 4 mm |
| Speed Display | LED Linear Bar Graph |
| Ambient Temperature Range | 4–45 °C |
| Rated Load Capacity | 5000 g |
| Power Supply | 220 V, 50 Hz |
| Input Power | 100 W |
| Timer Range | 1 min – 99 h 59 min |
| Dimensions (W×D×H) | 240 × 420 × 430 mm |
| Standard Accessories | Two foam tube racks (A250 & A515), replaceable tray垫 (B7) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XZS-50-II |
| Instrument Type | Vacuum Oven |
| Temperature Range | RT+10 to 250 °C |
| Temperature Uniformity | ±0.5 °C |
| Chamber Dimensions (per chamber) | 415 × 370 × 345 mm (W×D×H) |
| Temperature Resolution | 0.1 °C |
| Operating Ambient Temperature | 5–45 °C |
| Inner Chamber Material | 304 Stainless Steel |
| Heating Method | Forced-Air Circulation (External Heating) |
| Ultimate Vacuum Level | ≤133 Pa |
| Cabinet Configuration | Stacked Dual-Chamber Vertical Design |
| Brand | DreTop |
|---|---|
| Origin | Shanghai, China |
| Model | YU-3GW |
| Instrument Type | Magnetic Stirring Water Bath |
| Speed Range | 0–1200 rpm |
| Temperature Range | +5 to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability (at 37 °C) | ±0.5 °C |
| Bath Capacity | 3 L |
| Power Supply | 220 V ±10%, 50 Hz |
| Total Power | 300 W |
| Stirring Motor | DC 8 W |
| Construction | 304 Stainless Steel Bath & Lid, PP/High-Temp Resistant Control Housing, Powder-Coated Steel Enclosure |
| Heating Method | U-shaped Immersion Heater |
| Temperature Sensor | CU50 RTD |
| Display | LED Digital |
| Control | PID with Auto-Tuning |
| Safety Options | Optional Over-Temperature and Low-Water Alarms |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZAI-350 Series |
| Price Range | USD 5,100–11,000 (FOB) |
| Instrument Type | Manual Anaerobic Incubator |
| Oxygen Concentration Range | 0.1–25% (v/v) |
| Temperature Control Range | RT + 3°C to 60°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Sample Chamber Dimensions (W×D×H) | 400 × 300 × 280 mm |
| Gas Supply Configuration | Vacuum-assisted gas exchange with micro-flow-controlled N₂ (99.99%), mixed gas (85% N₂ / 5% H₂ / 10% CO₂), and integrated catalytic oxygen scavenging |
| Anaerobic Maintenance Duration (after gas cutoff) | >12 h at O₂ ≤1% |
| Construction | 304 Stainless Steel Interior & Glove Port Housing |
| Viewing Window | 12 mm Tempered Glass |
| Vacuum Pump | Oil-free Piston Type |
| Safety Features | Over-temperature Alarm (audible/visual), Power Failure Memory, Auto Fault Detection, UV Sterilization Lamp (standard) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ZAI-350-II |
| Temperature Range | RT+3°C to 60°C |
| Temperature Uniformity & Fluctuation | ±1°C |
| Oxygen Concentration Range | 0.1–20% (v/v) |
| Gas Supply Options | Single-gas (premixed anaerobic gas: 5% H₂ + 10% CO₂ + 85% N₂) or dual-gas (separate N₂ and premixed gas cylinders) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Anaerobic Maintenance Duration | >12 h after gas supply cessation |
| Vacuum Pump | Oil-free dry diaphragm pump |
| Viewing Window | 12 mm tempered glass |
| Interior Material | 304 stainless steel |
| UV Sterilization | Integrated germicidal lamp |
| Control Interface | LCD display with touch-enabled operation (ZAI-350-II variant includes real-time O₂ % readout and local atmospheric pressure monitoring) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | ZAI-350Plus |
| Instrument Type | Automated Anaerobic Incubator |
| Temperature Range | RT+3°C to 65°C |
| Temperature Uniformity & Stability | ±0.1°C |
| Oxygen Concentration Range | 0.1–25% (displayable in % or ppm) |
| Gas Supply Modes | Vacuum evacuation, gas purging, mixed gas (85% N₂ / 5% H₂ / 10% CO₂), and ultra-high-purity N₂ (99.99%) |
| Chamber Dimensions (W×D×H) | 1200 × 730 × 1320 mm |
| Humidity Control | Natural (unregulated) |
| Internal Construction | 304 Stainless Steel Chamber |
| Viewing Window | 12 mm Tempered Glass |
| Vacuum Pump | Oil-free Dry Piston Pump |
| Power Supply | 220 V, 50 Hz |
| Input Power | 650 W |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manual Anaerobic Incubator |
| Model | ZAI-350R |
| Temperature Range | 4–60°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| O₂ Concentration Range | 0.1–25% |
| Gas Supply | Pre-mixed Gas (5% H₂ + 10% CO₂ + 85% N₂) |
| Chamber Dimensions (W×D×H) | 800 × 690 × 660 mm |
| Operating Voltage | 220 V, 50 Hz |
| Power Consumption | 650 W |
| Anaerobic Maintenance Duration | >12 h (after gas supply cessation) |
| Vacuum Pump | Oil-free dry diaphragm pump |
| Viewing Window | 725 × 275 mm tempered glass (12 mm thick) |
| Construction | 304 stainless steel inner chamber, cold-rolled steel outer shell with electrostatic powder coating |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT+5°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control Range & Accuracy | 95% RH ±3% RH |
| Chamber Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Standard Features | Access Port for Sampling, Independent Over-Temperature Protector, RS485 Communication Interface, Programmable Controller, Micro-Printer Output, Real-Time Humidity Display System, Integrated Pressure-Reducing Valve |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Type | Water-Jacketed CO₂ Incubator |
| CO₂ Sensing | Thermal Conductivity (TC) Sensor |
| Temperature Control Range | RT + 5°C to 60°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range | 0–20% vol |
| CO₂ Accuracy | ±0.1% vol |
| Humidity Control Method | Natural Evaporation (95% RH ±3%) |
| Capacity | 50 L – 270 L (ZCQ/ZCW standard models) |
| External Dimensions | 545×465×710 mm – 750×715×1030 mm |
| Standard Configuration | HEPA Air Filter (≥0.3 µm, 99.998% efficiency), Mirror-Finish Stainless Steel Interior, Water Jacket with Low-Water Alarm & Auto Cut-off, Door Heating System, Infrared CO₂ Sensor, 90°C Wet-Heat Sterilization (optional), Ozone-Free UV Lamp |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR), Single-Beam Dual-Wavelength Sensor |
| Temperature Control Range & Accuracy | RT+3°C to 55°C, ≤ ±0.1°C |
| Temperature Uniformity | ≤ ±0.3°C |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% |
| Humidity Control | 95% RH ±3% |
| Chamber Capacity | 160 L (nominal) |
| External Dimensions (W×D×H) | 650 × 620 × 950 mm |
| Internal Dimensions (W×D×H) | ≥500 × ≥530 × ≥630 mm |
| Standard Configuration | UV Germicidal Lamp (Ozone-Free), ULPA Air Filtration (≥99.999% @ 0.3 µm), Reservoir-Type Humidity Pan, Heated Inner Glass Door, Silver-Ion Antimicrobial Coating, RS485 Data Interface |
| Optional Features | 90°C Wet-Heat Sterilization Cycle, Reversible Door Hinge, Multi-Tier Stackable Design |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | 4–60 °C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol |
| Chamber Capacity | 150 L |
| External Dimensions (W×D×H) | 605 × 625 × 1375 mm |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (natural evaporation) |
| Chamber Capacity | 160 L |
| Internal Dimensions (W×D×H) | 500 × 490 × 650 mm |
| Standard Configuration | UV Germicidal Lamp (ozone-free) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT+5°C to 60°C |
| Temperature Uniformity | ±1°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (Natural Evaporation) |
| Chamber Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Standard Configuration | UV Germicidal Lamp (Optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (Natural Evaporation) |
| Chamber Capacity | 270 L |
| External Dimensions (W×D×H) | 600 × 600 × 750 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Thermal Conductivity (TC) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C, ±0.2°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (natural evaporation via reservoir-based humidification) |
| Capacity | 270 L |
| Internal Dimensions (W×D×H) | 600 × 590 × 750 mm |
| Standard Configuration | UV Germicidal Lamp (ozone-free) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 270 L |
| Internal Dimensions (W×D×H) | 600 × 600 × 750 mm |
| Standard Configuration | UV Germicidal Lamp (Optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 50 L |
| External Dimensions (W×D×H) | 475 × 496 × 735 mm |
| Internal Dimensions (W×D×H) | 345 × 355 × 410 mm |
| Standard Configuration | UV Germicidal Lamp (Optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT+5°C to 60°C, ±0.2°C |
| Temperature Uniformity | ±0.2°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 50 L |
| External Dimensions (W×D×H) | 545 × 465 × 710 mm |
| Standard Configuration | RS485 Communication Interface, Silicone Tube Port |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (Natural Evaporation) |
| Chamber Volume | 50 L |
| External Dimensions (W×D×H) | 475 × 496 × 735 mm |
| Internal Dimensions (W×D×H) | 345 × 355 × 410 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (Natural Evaporation) |
| Chamber Capacity | 80 L |
| External Dimensions (W×D×H) | 400 × 400 × 500 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT +5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 80 L |
| External Dimensions (W×D×H) | 400 × 400 × 500 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 160 L |
| External Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Standard Configuration | UV Germicidal Lamp (Optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C, ±0.2°C |
| Temperature Uniformity | Not specified in source data |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (natural evaporation) |
| Chamber Capacity | 160 L |
| Internal Dimensions (W×D×H) | 500 × 500 × 650 mm |
| Standard Configuration | UV Germicidal Lamp (optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT +5°C to 60°C, ±0.2°C |
| Temperature Uniformity | Not specified in datasheet |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (natural evaporation) |
| Chamber Volume | 270 L |
| External Dimensions (W×D×H) | 775 × 765 × 1050 mm |
| Internal Dimensions (W×D×H) | 600 × 600 × 750 mm |
| Standard Configuration | UV Germicidal Lamp (optional 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C, ±0.2°C |
| Temperature Uniformity | Not specified (consult technical support) |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (natural evaporation via water reservoir) |
| Chamber Capacity | 270 L |
| External Dimensions (W×D×H) | 775 × 765 × 1050 mm |
| Internal Dimensions (W×D×H) | 600 × 600 × 750 mm |
| Standard Configuration | UV Germicidal Lamp (254 nm, ozone-free) |
| Optional | 90°C High-Temperature Humid Heat Sterilization Cycle |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT+5°C to 60°C, ±0.2°C uniformity |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | Natural evaporation, ≥95% RH (±3% RH) |
| Capacity | 50 L |
| External Dimensions (W×D×H) | 475 × 496 × 735 mm |
| Internal Dimensions (W×D×H) | 345 × 355 × 410 mm |
| Standard Configuration | UV Germicidal Lamp (Ozone-Free), Stainless Steel Reservoir-Type Humidity Pan, Heated Inner Glass Door, Water Level Monitoring System |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH |
| Chamber Capacity | 50 L |
| External Dimensions (W×D×H) | 475 × 496 × 735 mm |
| Internal Dimensions (W×D×H) | 345 × 355 × 410 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | RT + 5°C to 60°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol, ±0.1% vol |
| Humidity Control | 95% RH ±3% RH (Natural Evaporation) |
| Chamber Capacity | 80 L |
| External Dimensions (W×D×H) | 400 × 400 × 500 mm |
| Standard Configuration | UV Germicidal Lamp (Optional: 90°C High-Temperature Humid Heat Sterilization) |