| Brand | EcoTech |
|---|---|
| Model | PhenoTron®-SR |
| Origin | Beijing, China |
| Imaging Modalities | Hyperspectral (400–1000 nm & 900–1700 nm), UV-MCF Fluorescence Hyperspectral, Chlorophyll Fluorescence Imaging (LEDIF & Full-Frame), Thermo-RGB Fusion |
| Spatial Resolution | Up to 1024 px (VIS-NIR), 640 px (SWIR), 20 MP RGB + 640×512 IR |
| Spectral Channels | 440 (VIS-NIR), 220 (SWIR) |
| Positioning Accuracy | ±1 mm (XYZ robotic stage) |
| Software | SpectrAPP, FluorVision, EcoTech GUI (touchscreen + PC client, wireless control) |
| Compliance | Designed for GLP-aligned plant phenotyping workflows |
| supports audit-ready metadata logging, protocol versioning, and ROI-based parameter export per ISO 20673 | 2019 (Plant Phenomics — Data Acquisition and Management Principles) |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PheoPlot® Portable |
| Spectral Range (Standard) | 400–1000 nm (448 bands, F/1.7, 1024-pixel spatial resolution, SNR ≥ 400:1, 330 FPS full-frame) |
| Spectral Range (Optional) | 900–1700 nm (224 bands, F/1.7, 640-pixel spatial resolution, SNR ≥ 1000:1, 670 FPS full-frame) |
| Thermal Imaging | 640 × 512 IR resolution, −20 °C to +150 °C |
| RGB Imaging | 20 MP |
| Platform Span | 1.5 m (standard), up to 2.0 m (optional) |
| Height Adjustment | 50–160 cm |
| Positioning Accuracy | <1 mm |
| Battery Life | >8 h (dual Li-ion, parallel configuration) |
| Software | Embedded Linux OS + Windows PC GUI with protocol scripting (up to 10 automated sequences) |
| Compliance | Designed for GLP-aligned field phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Europe |
| Model | PTM-NG26 |
| Sensor Type | Distributed PLS-10R Intelligent Leaf Sensors |
| Measurement Principle | Open-system gas exchange with integrated microclimate sensing |
| Deployment Range | Up to 30 m per sensor node |
| Data Output | Net CO₂ assimilation rate (A<sub>net</sub>, µmol CO₂·m⁻²·s⁻¹), Transpiration rate (E, mmol H₂O·m⁻²·s⁻¹), Stomatal conductance (g<sub>s</sub>, mol H₂O·m⁻²·s⁻¹), Intercellular CO₂ concentration (C<sub>i</sub>, µmol·mol⁻¹), Leaf temperature (T<sub>L</sub>, °C), Leaf–air temperature differential (ΔT, °C), Photosynthetically Active Radiation (PAR, µmol·m⁻²·s⁻¹), Ambient air temperature & relative humidity, Atmospheric CO₂ concentration (µmol·mol⁻¹), Barometric pressure (kPa), Vapor Pressure Deficit (VPD, kPa) |
| Data Storage | Local SD card + cloud synchronization via secure HTTPS API |
| Compliance | Designed for GLP-aligned experimental workflows |
| Brand | EcoTech |
|---|---|
| Model | RhizoTron® |
| Origin | Beijing, China |
| Core Technology | Hyperspectral Imaging (400–1000 nm, optional 900–1700 nm) + UV-Induced Autofluorescence Imaging |
| Imaging Platform | Motorized Tilt-Scanning Stage (60° standard, optional 45°/70°/90°) |
| Spectral Resolution | <5 nm (VIS-NIR), <10 nm (SWIR) |
| Spatial Resolution | ≤0.1 mm/pixel at 10 cm working distance |
| RGB Sensor | 2448 × 2048 pixels |
| Software Suite | PhenoRoot™ (root morphology), SpectrAPP® (hyperspectral analytics), optional Thermo-RGB Fusion & Chlorophyll Fluorescence Analysis Modules |
| Compliance | Designed for GLP-compliant plant phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Imported (Sensors & Data Logger: Europe |
| Rhizotron Imaging Unit | USA) |
| Model | SoilTron-Rhizo |
| Construction | Stainless Steel Cylinder (Rhizo-50: Ø125 cm, H=250 cm, 3 mm wall |
| Rhizo-80 | Ø200 cm, H=375 cm, 4 mm wall) |
| Root Observation Zones | 4 (Rhizo-50) or 5 (Rhizo-80) horizontal layers |
| Soil Moisture Sensors | TRIME PICO 32 TDR probes (0–100% vol., ±1% @ 0–40%, IP68) |
| Temperature Range | –15–50 °C (±0.2 °C) |
| Imaging System | SuperHAD II 1/3" IT CCD, 768×494 px, 30 fps, 55° FOV, 360° rotatable mirror tube, fiber-optic illumination |
| Data Logger | 16-channel (optional 32), 16-bit resolution, ±20 mV to ±2.5 V, 0.03% accuracy, 220,000 timestamped records, 3 s–4 h sampling interval, GSM/GPRS/Internet telemetry |
| Software | RootFly (standard), WinRhizo (optional), proprietary data analysis suite with statistical aggregation, regression, and time-series visualization |
| Compliance | Designed for GLP-aligned long-term ecological monitoring |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | SpectraScan-R |
| Imaging Modality | VIS-NIR Hyperspectral + High-Resolution RGB Scanning |
| Spectral Range (Standard) | 400–1000 nm |
| Optional Extensions | 900–1700 nm or 1000–2500 nm SWIR |
| Spatial Resolution | 512 × 512 pixels (configurable to 1024 × 1024) |
| Spectral Resolution | 7 nm (204 bands) |
| Field of View | 31° (55 × 55 cm at 1 m) |
| Imaging Distance | 15 cm to infinity |
| Integrated Touchscreen | 4.3″ with 13 physical control keys |
| Data Acquisition Mode | Push-broom with embedded preview camera (5 MPix) |
| Software Platform | WinRHIZO Pro (Professional Edition) with Scanner.cal calibration support, SAM classification, Savitzky-Golay spectral smoothing |
| Compliance | Compatible with GLP-compliant data workflows |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | SSI-ET Modular |
| Instrument Type | Research-grade rodent (mouse/rat) metabolic phenotyping system |
| Channel Configurations | 4-, 8-, 16-, or scalable multi-channel (up to 24+) |
| Gas Analytes | CO₂ (0–5% / 0–15%, dual-range NDIR), O₂ (0–100%, paramagnetic), H₂O (RH 0.2–100%, dew point −40 to +40°C) |
| Flow Control | Precision mass flow controllers (5–2000 mL/min), thermal-mass flow meters (±2% accuracy) |
| Data Acquisition | 12-channel DAQ (8 × 16-bit analog, 4 × dedicated thermistor inputs, 100 Hz sampling) |
| Software | EcoMetab v5.x with real-time RQ, VO₂, VCO₂, EE calculation |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Optional Modules | Implantable telemetry (E-mitter compatible), infrared thermography integration, activity monitoring (beam-break/PIR), environmental control (T/RH/O₂/CO₂ regulation), cage-integrated load cells & fat temperature sensors |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo-RGB Integrated |
| Pricing | Upon Request |
| IR Resolution | 640 × 512 pixels |
| Thermal Sensitivity | 30 mK |
| Temperature Range | −25 °C to +150 °C |
| Accuracy | ±2 °C or ±2% of reading |
| Spectral Band | 7.5–13.5 µm |
| RGB Resolution | 20 MP (configurable to higher) |
| Calibration | Multi-point blackbody calibrated with traceable certificate |
| Fusion Technology | Pixel-level co-registered thermal–visible alignment with four built-in segmentation models and eight combinable algorithms |
| Brand | EcoTech |
|---|---|
| Origin | Canada |
| Model | WinSCANOPY |
| Software Versions | WinSCANOPY Mini LS, Reg, Pro |
| Image Input | Hemispherical (fisheye) or narrow-angle canopy images |
| Platform | Windows OS |
| Compliance | Designed for ISO 13837, ASTM E2916, and FAO-recommended LAI protocols |
| Data Export | CSV, Excel, XML |
| Optional Hardware | Calibrated fisheye lens, tripod, remote shutter release |
| Upgrade Path | Linear version upgrade (Mini LS → Reg → Pro) via license key |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | Zebrafish High-Throughput |
| Detection Technology | Fluorescent Fiber-Optic Oxygen Sensing |
| Channel Capacity | 96 simultaneous channels |
| Oxygen Measurement Accuracy | ±0.1% O₂ @ 1% O₂ or ±0.05 mg/L @ 0.44 mg/L |
| Oxygen Resolution | 0.01% O₂ @ 1% O₂ or 0.005 mg/L @ 0.44 mg/L |
| Response Time | <30 s |
| Temperature Sensor Range | 0–50°C, Resolution: 0.012°C, Accuracy: ±0.5°C |
| Pressure Sensor Range | 300–1100 mbar, Resolution: 0.11 mbar, Accuracy: ±6 mbar |
| Max Sampling Frequency | 10–20 Hz per active channel |
| Power Supply | 5 VDC via USB |
| Dimensions (O₂ Host) | 162 × 102 × 32 mm |
| Weight (O₂ Host) | 670 g |
| Chamber Material | Sterilizable transparent polystyrene |
| In Situ Compatibility | Yes — designed for incubators and orbital shakers |
| Non-Invasive & Non-Destructive Operation | Yes |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FluorTron®-Robot |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Finland |
| Model | GrainSense |
| Type | Handheld / Flow-through / Benchtop NIR Seed Analyzer |
| Measurement Principle | Near-Infrared (NIR) Transmittance Spectroscopy |
| Key Parameters | Protein, Moisture, Fat, Carbohydrates |
| Sample Throughput | 3 g (handheld), ~100 g/s (flow-through) |
| Operating Temp | 5–45 °C (handheld), 0–45 °C (flow-through) |
| Communication | Bluetooth LE 5.0 (handheld), Ethernet/RS-485 (flow-through) |
| Compliance | CE, RoHS, IP65 (flow-through enclosure), GLP-supporting data logging |
| Brand | EcoTech |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | METOS® |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | USA |
| Model | P3500 |
| Sensor Types | EC, VisNIR, Capacitance, Penetrometer |
| Max. Profiling Depth (Auto) | 60 cm |
| Max. Profiling Depth (Manual) | 90 cm |
| Sampling Resolution | 240 data points per insertion |
| Data Acquisition Rate | 1 Hz |
| GPS Integration | Yes |
| Sampling Tube Included | Yes |
| Compliance | ASTM D698/D1557 (soil compaction), ISO 11277 (soil texture), ISO 13879 (EC measurement), USP <1058> (analytical instrument qualification framework) |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoTron® |
| Key Features | Integrated LED cultivation, hyperspectral imaging (400–1000 nm), fiber-optic O₂/pH/temperature sensing, chlorophyll fluorescence imaging (FluorCam), thermal infrared (Thermo-RGB), high-throughput 96-well respirometry (REDFLASH), programmable circadian lighting (0–500 µmol·m⁻²·s⁻¹ PAR), morphometric seed & root phenotyping |
| Compliance | Designed for ISO/IEC 17025-aligned lab workflows, supports GLP-compliant data audit trails and FDA 21 CFR Part 11–ready software modules (optional) |