FPI
Filter
Showing 121–150 of 163 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MAX-DOAS |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Instrument Type | Online Aerosol Organic Carbon/Elemental Carbon Analyzer |
| Measurement Principle | Thermal-Optical Transmittance (TOT) or Thermal-Optical Reflectance (TOR) |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040-compatible protocols |
| Sample Inlet | Standard PM2.5 or PM10 inlet with heated line (optional) |
| Detection Method | Laser transmittance/reflectance monitoring during thermal desorption |
| Flow Control | Proportional solenoid valves + mass flow controllers (MFCs) |
| Furnace Construction | High-purity alumina ceramic furnace bricks with ceramic fiber-insulated heating elements |
| OC/EC Split Point Determination | Automated optical carbon charring correction algorithm |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OCEC-100 |
| Instrument Principle | Thermal-Optical Transmission/Reflection (TOT/TOR) |
| Configuration | Continuous Online Monitoring System |
| Compliance | Designed for ASTM D7520, IMPROVE_A, NIOSH 5040, EUSAAR-2 protocol alignment |
| Data Output | Real-time OC/EC mass concentration (µg/m³), split point identification, charring correction trace |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | OMA-3000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Hangzhou) Co., Ltd. |
| Model | OMA-3220 |
| Type | UV Absorption Spectrophotometric Analyzer |
| Detection Principle | Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Measurement Range | Sub-ppm to low-ppm H₂S |
| Detection Limit | < 10 ppb (typical, dependent on path length and optics) |
| Light Source | Pulsed Xenon Flash Lamp |
| Design | Solid-state, module-based, no moving parts |
| Calibration | Automated zero/span and self-diagnostic cycle |
| Compliance | Designed for continuous industrial process monitoring per IEC 61511 functional safety guidelines (SIL2-capable architecture), compatible with ISO 8573-1 compressed air purity class monitoring workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OMA-3510 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ONH5000 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.00001–3.0 wt% |
| Nitrogen Range | 0.00001–3.0 wt% |
| Hydrogen Range | 0.00000–0.25 wt% |
| Oxygen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Nitrogen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Hydrogen Precision | ±0.00002 wt% or RSD ≤ 2.0% |
| Sensitivity | 0.000001 wt% |
| Typical Analysis Time | 120–180 s (including purge, delay, and measurement) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ONH5000 |
| Power Supply | 8.0 kW Pulse Electrode Furnace |
| Max Furnace Temperature | >3500 °C |
| Detection Principles | Infrared Absorption (O), Thermal Conductivity (N, H) |
| Carrier Gases | He or N₂ |
| Compliance | ASTM E1019, ISO 14284, GB/T 11261–2022, GB/T 20123–2006 |
| Sample Form | Solid metallic & non-metallic materials |
| Measurement Elements | O, N, H (simultaneous or individual) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PMS-200 |
| Configuration | Dual-Channel Integrated Sampler |
| Flow Rate | Single-Channel: 16.67 L/min |
| Dual-Channel | 15 L/min (PM₂.₅) and 16.67 L/min (PM₁₀–PM₂.₅) |
| Vacuum Pressure Range | 80–106 kPa |
| Flow Stability | ≤2% of setpoint over 24 h |
| Maximum Flow Accuracy | ±2% of setpoint |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Service Life Under Max Load & Resistance | 2–3 years |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMS-200A |
| Configuration | Integrated Low-Flow PM Sampler |
| Nominal Flow Rate | 16.67 L/min |
| PM10 & PM2.5 Fractionation | Equipped with ISO/EPA-compliant impactor or cyclonic PM2.5 separator |
| Filter Capacity | 16 pre-loaded filters per cassette |
| Automation | Pneumatically actuated filter exchange |
| Environmental Operating Range | -30 °C to +50 °C with active thermal regulation |
| Data Interface | RS-232, USB, and GPRS telemetry |
| Compliance | Designed to meet EPA Reference Method EQPM-0899-004, ISO 23270:2023 (Ambient air — Measurement of mass concentration of PM2.5 and PM10), and Chinese HJ 93-2013 technical specifications |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PMS-200M |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Ambient Air Sampler |
| Instrument Architecture | Multi-Channel Sequential Gas & Aerosol Sampler |
| Flow Range | Customizable (Typical Standard Range: 16.7–100 L/min per Channel) |
| Pressure Drop Handling | Up to 25 kPa (at max flow) |
| Flow Stability | ±2% over 24 h (with active feedback control) |
| Flowmeter Accuracy | ±1.5% of reading (NIST-traceable thermal mass flow sensors) |
| Rated Service Life at Max Load | ≥12,000 operating hours |
| Continuous Operation Duration at Max Flow & Backpressure | ≥24 h per cycle |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Pre-3000 + 315 VOC Online Analyzer |
| Product Category | Atmospheric VOC Online Monitoring System |
| Measurement Principle | Cryogenic Preconcentration Coupled with Capillary Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Detection Target | C2–C12 Volatile Organic Compounds (VOCs), including alcohols, ketones, esters, halogenated hydrocarbons, and aromatic compounds |
| Typical Detection Limit | Sub-ppbv (dependent on compound, integration time, and system configuration) |
| Water Removal Efficiency | >99% at −100 °C |
| Cryogenic Temperature Range | −100 °C to ambient |
| Thermal Desorption Rate | >40 °C/s (direct-resistive heating) |
| Carrier Gas Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for H₂, air, and carrier gas (N₂ or He) |
| Enclosure | 19-inch rack-mount industrial chassis (standard 4U height) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GC-2000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ProGC-3010 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QCD |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | RC-1000/2000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | SG-100 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SP-3800 Series |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1000 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 600–1100 nm & 1000–1800 nm |
| Analysis Time | <30 s |
| Wavelength Repeatability | ±0.05 nm |
| Sampling Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1200 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | <1 second per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Compliance | CE, RoHS (as per manufacturer documentation) |
| Power Supply | Integrated rechargeable lithium-ion battery |
| Connectivity | Bluetooth 4.2 + Android mobile application |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1500 |
| Instrument Type | Portable |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 spectrum/sec |
| Spectral Resolution | 1 nm sampling interval |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Detector | TE-Cooled InGaAs |
| Chemometrics Software | RIMP |
| Power Supply | Integrated Rechargeable Battery |
| Display | Built-in LCD |
| Data Storage | Onboard Memory |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1500 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1520TM |
| Instrument Type | Portable |
| Optical Principle | Holographic Gold-Coated Concave Grating Scanning |
| Detection Mode | Diffuse Reflectance |
| Software | RIMP Chemometrics Platform |
| Compliance | Designed for ISO 17025-aligned textile testing workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Scanning Grating with TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm |
| Spectral Resolution | ≤ 8 nm (FWHM) |
| Wavelength Accuracy | ±0.2 nm |
| Data Sampling Interval | 1 nm |
| Scan Speed | Full-spectrum acquisition in < 60 s |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP v4.x (with PLS, PCR, SVM, and model validation modules) |
| Temperature Control | Integrated Peltier-based sample compartment (±0.1 °C stability) |
| Compliance | Meets ISO 12099:2017 for NIR instrument performance verification |
| Connectivity | Ethernet (RJ45), USB 2.0, optional Wi-Fi module |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Spectral Acquisition Speed | 0.2 s per spectrum |
| Spectral Resolution | 1 nm data sampling interval |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Detector | Thermoelectrically Cooled (TEC) InGaAs Array |
| Sample Handling | Motorized Rotating Sample Tray |
| Built-in Reference Standards | Yes |
| Network Connectivity | Ethernet & USB |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-3000 |
| Instrument Type | Laboratory |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 scan/s |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Digital Grating + TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm (expandable to 1000–2500 nm) |
| Scanning Mechanism | Grating-Based Wavelength Scanning |
| Software Platform | RIMP Chemometrics Suite (Chinese UI) |
| Connectivity | Ethernet, USB, Remote Management via Web-Based Instrument Control Platform |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail (via RIMP logging) |