Generic
Filter
Showing 331–360 of 1032 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GB-EFA1 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4008B |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Safety & Spontaneous Combustion Monitoring |
| Detection Systems | TCD, Dual FID, ECD, FPD |
| Column Configuration | Four Dedicated Capillary/Packed Columns |
| Temperature Program | 10-Stage Programmable Ramp |
| Carrier Gases | Helium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD) |
| Minimum Detectable Concentrations | CO, C₂H₂ ≤ 0.5 ppm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC-4075 |
| Pricing | Upon Request |
| Measurement Method | Dual-Channel Flow Chromatographic Oxygen Adsorption Method |
| Oxygen Uptake Range | 0.05–4 mL/g (coal) |
| Measurement Error | ≤5% |
| Baseline Drift | ≤0.6 mV/hr |
| Carrier Gas Purity | N₂ ≥99.99% |
| Adsorption Gas Purity | O₂ ≥99.99% |
| Sensitivity | ≥10 mV/mL (N₂ carrier, O₂ peak height) |
| Temperature Control Accuracy | ±0.5°C |
| Power Supply | 220 V ±20%, 50 Hz ±0.5 Hz, 500 W |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4085 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDP-C |
| Pricing | Available Upon Request |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKTAprocess |
| Pricing | Available Upon Request |
| Flow Rate Options | 4–180 L/h, 13–600 L/h, 45–1800 L/h |
| Column Compatibility | AxiChrom® |
| UV Detection | Single-wavelength (280 nm) or Multi-wavelength |
| pH Range | 0–14 |
| Conductivity Range | 1–200 mS/cm |
| Enclosure Rating | NEMA 4X / IP56 |
| Electrical Compliance | UL 508A, EN 61010-1 |
| Max Operating Pressure | PP tubing (6 bar @ ≤40 °C) |
| Operating Temperature | Ambient 2–30 °C |
| Process Fluid | PP system 4–60 °C (3 bar max at 40–60 °C) |
| Dimensions (L×W×H) | 1205 × 850 × 1670 mm |
| Temperature Range | -70°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ≤2.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±2.0°C |
| Humidity Deviation | +2 / -3% RH |
| Heating Rate | 35 min (20°C → 100°C) |
| Cooling Rate | 25 min (20°C → 0°C), 40 min (20°C → -20°C), 60 min (20°C → -40°C), 90 min (20°C → -70°C) |
| Construction | SUS304B outer shell, welded stainless steel test chamber interior |
| Sealing | Dual-layer silicone rubber door gasket |
| Insulation | High-density mineral wool |
| Access Port | One 50 mm diameter cable port (left side) |
| Air Circulation | Axial fan(s), quantity dependent on chamber volume |
| Compliance | Designed for ISO 16750-4, IEC 60068-2-14, MIL-STD-810H environmental stress screening (ESS) protocols |
| Impact Table Surface | 200 × 200 mm |
|---|---|
| Maximum Load Capacity | 10 kg |
| Pulse Duration Range | 0.2–100 ms (programmable, auto-controlled) |
| Peak Acceleration Range | 50–9999 m/s² |
| Waveform Type | Half-sine |
| Shock Direction | Vertical |
| Deceleration Mechanism | Hydraulic-friction dual-stage arrestor |
| Height Adjustment | Digital preset + hydraulic lifting |
| Control & Measurement System | Integrated real-time acquisition unit |
| Frame Weight | 2800 kg |
| Dimensions (W×L×H) | 750 × 2600 × 1000 mm |
| Power Supply | AC 380 V ±10%, 50 Hz, 3 kVA |
| Repetition Rate | 0–100 shocks/min |
| Sampling Rate | 200 kHz |
| Filtering | Analog anti-aliasing + 160 dB/octave digital anti-aliasing filter |
| Compliance Standards | IEC 60068-2-27, GB/T 2423.5, GJB 150.18A, GJB 360B, JJG 497 |
| Software Platform | Windows XP-based with DAO engine, automated Word report generation, real-time display of height, acceleration amplitude, pulse width, and Δv |
| Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T-200B |
| Price Range | USD 1,400 – 7,000 |
| Measurement Range | 600 / 1000 / 1500 mm |
| Collection Area | 200 cm² |
| Sensitivity | 0.05 / 0.075 / 0.1 mm |
| Accuracy | ±0.1% FS |
| Repeatability | ±0.1 / ±0.1 / ±0.15 mm |
| Power Supply | 8–24 V DC, 15 mA |
| Heated Option | 24 V or 220 V AC |
| Output | Square Wave 0–5 V and SDI-12 |
| Operating Temperature | −40 °C to +60 °C |
| Humidity | 0–100% RH |
| Temperature Drift | 0.001% FS/°C |
| Housing Material | Anodized Aluminum |
| Dimensions (Ø × H) | 390 × 760 / 800 / 1000 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AC-73-DH |
| Instrument Type | Portable |
| Dynamic Range | 165 dB |
| Full-Scale Range | ±0.5, ±1, ±2, ±3, or ±4 g |
| Bandwidth | DC to 200 Hz |
| Power Supply | 9.5–18 V DC (galvanically isolated) |
| Housing Compatibility | ≥100 mm borehole diameter |
| Sensor Architecture | Electro-mechanical force-balance with capacitive position sensing and magnetic restoring force |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SM-3 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RD-8 |
| Detection Target | Milk Powder Moisture Content |
| Automation Level | Fully Automatic |
| Analysis Speed | 250 samples per hour (not per minute — corrected per industry standard for gravimetric moisture analyzers) |
| Sample Capacity | 8 positions |
| Temperature Range | Adjustable up to 110 °C |
| Temperature Stability | ±0.3 °C |
| Air Flow Rate | 33 mL/min at 87 °C |
| Compressed Air Requirement | 2.5–7.5 bar |
| Power Supply | 230 V / 115 V, 520 W |
| Dimensions | 185 mm × 240 mm × 450 mm |
| Weight | 9.5 kg |
| Repeatability | <1% RSD |
| Accuracy | <1% deviation vs. reference oven-drying method |
| Compliance | ISO 5537, IDF 26, equivalent to GB/T 5009.3 (Chinese National Standard) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | GGR01 |
| Price Range | USD 72–143 |
| Component Category | Optical Element |
| Substrate Material | Float Glass |
| Surface Quality | Grade 4 |
| Dimensional Tolerance | ±0.5 mm |
| Thickness Tolerance | ±0.5 mm |
| Diffraction Efficiency | 60–80% @ Blaze Wavelength |
| Clear Aperture | ≥90% |
| Laser Damage Threshold | 350 mJ/cm² (200 ns pulsed, 10.6 µm) |
| Groove Density Options | 75, 100, 150 lines/mm (IR) |
| Blaze Wavelengths | 30 nm, 500 nm, 1000 nm, 10.6 µm |
| Blaze Angles | 2°34′ to 35°0′ |
| Dispersion | 3.30–12.3 nm/mrad |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GHX-1000 |
| Rental Rate | USD 2,800/month (excl. tax & shipping) |
| Compliance | CE-marked modules, NIST-traceable calibration options available |
| Software | Cloud-based remote monitoring dashboard with real-time data streaming and audit-log export |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model Range | OPGT/OPGL/OPGM/OPWT Series (25.4 mm OD, 10 mm clear aperture) |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GR 1300/13 |
| Quotation | Upon Request |
| Max Temperature | 1300 °C |
| Heating Length | 1300 mm |
| Heating Zones | 6 independent zones (each 160 mm) |
| Max Achievable Axial Temperature Gradient | 400 °C |
| Internal Dimensions (W×D×H) | 1300 × 100 × 60 mm |
| External Dimensions (W×D×H) | 1660 × 740 × 1345 mm |
| Power Rating | 18 kW |
| Electrical Supply | 3-phase |
| Net Weight | 300 kg |
| Heating Method | Radiant heating via resistance wire wound on ceramic support tubes |
| Loading Access | Top or front door |
| Optional Accessory | Ceramic fiber partition boards for zone isolation |
| Key | Purity: 99.95% |
|---|---|
| Cu Thickness | 50 µm |
| Sheet Resistance | 300–500 Ω/□ |
| Monolayer Coverage | ≥90–96% (size-dependent) |
| Layer Count | Single-layer or 2–4 layers |
| Substrate Dimensions | Custom up to 45 cm × 50 cm |
| Storage | Dry, oxygen-free environment, <30°C, use within 30 days |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GT-1030 |
| Pricing | Available Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | GTM- |
| Price Range | USD 1,400 – 2,800 |
| Load Capacity Options | 0–5 kN, 0–10 kN, 0–20 kN, 0–50 kN |
| Measurement Accuracy | ±0.15% FS (Load), ±0.5% FS (Deformation) |
| Deformation Range | ±5 mm |
| Displacement Rate | 0–1 mm/min (adjustable) |
| Temperature Capability | GTM-1 — Ambient only |
| Sample Dimension Tolerance | Parallelism ≤0.02 mm, Perpendicularity ≤0.02 mm, Surface Roughness Rz ≤1.60 µm |
| Strain Gauge Length Limits | ≤1 mm (3-point bend), ≤5 mm (4-point bend) |
| Compliance Standards | GB/T 10700–2006, GB/T 6569, GB/T 1182, GB/T 1031 |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GUARDiON H2T |
| Dosage Volume | 5 L |
| Airflow Rate | 5 m³/min |
| Sterilization Chamber Capacity | 5 L (generator reservoir) |
| Vaporization Temperature | 25 °C |
| Dehumidification Setpoint | ≤30% RH |
| Filtration Efficiency | ≥99.9999% (HEPA + optional catalytic post-filter) |
| Sterilant | Aqueous hydrogen peroxide (7% w/w) |
| Log Reduction | ≥6-log (≥99.9999%) for Geobacillus stearothermophilus spores and enveloped/non-enveloped viruses |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GXH-3051 |
| Price | Upon Request |
| Measurement Range (CO₂) | 0–1000 ppm / 0–100% vol |
| Zero Drift | ≤ ±1% FS / 4 h |
| Span Drift | ≤ ±1% FS / 4 h |
| Linearity | ≤ ±1% FS |
| Repeatability | ≤ ±1% |
| Warm-up Time | 15 min |
| Weight | 1.5 kg |
| Display | Backlit LCD with Direct Concentration Readout |
| Gas Flow Control | Adjustable via Integrated Flow Regulator |
| Calibration Mode | Six-Port Manual Valve for Zero/Measurement Path Switching |
| Power | Dual Rechargeable Battery System with Low-Voltage Alert |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Online TOC Analyzer |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Online TOC Monitoring System |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Methods | UV/Persulfate, High-Temperature Combustion (680–900 °C), Ozone-Promoted Oxidation, Ultra-Pure UV Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±1% of reading |
| Resolution | 0.05 ppm C |
| Detection Limit | 0.05 ppm C |
| Repeatability | ±1% RSD |
| Sample Throughput | As low as 3 minutes per analysis (configuration-dependent) |
| Dimensions (H×W×D) | 575 × 556 × 612 mm |
| Weight | 60 kg |
| Power Supply | 220 VAC, 10 A |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DW-86L626 |
| Quotation | Upon Request |
| Climate Class | N |
| Cooling Method | Direct Cool |
| Defrost Mode | Manual |
| Refrigerant | Eco-friendly Mixed HFC Blend |
| Noise Level | <50 dB(A) |
| Power Consumption | 1200 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Internal Temperature Range | -40 °C to -86 °C |
| Temperature Uniformity | ±6 °C |
| External Dimensions (W×D×H) | 1035 × 900 × 1980 mm |
| Internal Dimensions (W×D×H) | 760 × 630 × 1310 mm |
| Net Capacity | 626 L |
| Net Weight | 301 kg |
| Compressor Type | Hermetic Reciprocating (Dual Unit) |
| Compressor Power | 927 W per unit |
| Door Configuration | 1 Outer Foam-Insulated Door + 4 Independent Inner Foam Doors |
| Insulation | VIP Vacuum Insulation Panels + Zero-ODP Polyurethane Foam |
| Temperature Control | Microprocessor-Based Digital Controller with LED Display |
| Temperature Sensor | Precision Thermistor |
| Shelving | Adjustable, Load Capacity 50 kg per shelf |
| Casters | Equipped with Locking Swivel Casters |
| Monitoring Ports | 1 Access Port for External Probe or Data Logger |
| Alarm System | Comprehensive Audible/Visual Alarms (High Temp, Low Temp, Power Failure, Door Ajar, Filter Clog, Sensor Fault, Ambient Over-Temp, Low Battery, Voltage Fluctuation) |
| Regulatory Compliance | Registered Medical Device (China NMPA) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DW-60W156 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CPG-100B-1000-P |
| Output Current | Up to 500 A (at 100 V supply, 5 ns pulse width, 300 pH parallel inductance) |
| Pulse Width | Fixed typ. 1–5 ns |
| Repetition Rate | Single-shot to 400 kHz |
| Timing Jitter | < 5 ps (additive) |
| Output Impedance (High-Current Driver Version) | 10–100 mΩ |
| Coupling | AC-coupled |
| RF Connector | Advanced SMA® |
| Trigger Input | 50 Ω terminated, TTL/CMOS compatible |
| Origin | UK |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Models | IRA-256, IRA-512 |
| Interface Options | USB 14-bit, PCI 12-bit |
| Pixel Count | 256 or 512 |
| Pixel Size | 50 µm × 500 µm |
| Pixel Pitch | 50 µm |
| Spectral Range | 800–1700 nm |
| Cooling Method | TE (Peltier) |
| Operating Chip Temperature | < +5 °C (at 24 °C ambient) |
| Full Well Capacity (typ.) | 5×10⁶ e⁻ (high-sensitivity mode), 130×10⁶ e⁻ (high-dynamic-range mode) |
| Read Noise (rms, typ.) | 800 e⁻ (HS), 10 k e⁻ (HDR) |
| Dark Current (rms, typ.) | 190 k e⁻/s (IRA-256), 182.2 k e⁻/s (IRA-512) |
| 1-s Dark Noise (rms, typ.) | 436 e⁻ (IRA-256), 426 e⁻ (IRA-512) |
| Integration Time | 0.01–10 s |
| Analog Output Range | 0–10 V |
| Frame Rate (real-time) | >20 spectra/s |
| Defective Pixel Count | ≤5 (non-adjacent) for IRA-512 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HANATEK CFA |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3886 |
| Safety Rating | Non-Explosion-Proof |
| Weight | ~980 g |
| Display | 4-line × 20-character LCD |
| Dimensions | 115 mm × 70 mm × 211 mm |
| Data Storage Capacity | 500 samples (4 records per test in Calculation Mode) |
| Communication Interface | RS-232 or RS-485 (selectable via menu) |
| Power Supply | 4× AA Ni-MH rechargeable batteries (4.8 V, 1.6 Ah) |
| Sampling Flow Rate | 0.1 cfm (2.83 L/min) |
| Counting Channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm |
| Minimum Detectable Particle Size | 0.3 µm |
| Count Range | 1–70,000,000 particles/ft³ |
| Sampling Duration | 1 s – 99 min 59 s (adjustable in 1-s increments) |
| Sampling Frequency | 1–99 cycles or continuous |
| Operating Temperature | 10–35 °C |
| Test Modes | Single, Repeat, Continuous, Calculation, Remote Control |
| Simultaneous Environmental Monitoring | Particle count + temperature + relative humidity + air velocity (with optional probes) |
| Error Indicators | Out-of-range count, laser power degradation, flow deviation > ±1%, low battery |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Dimensions (HAST-25) | Ø250 × 450 mm |
| Internal Dimensions (HAST-35) | Ø350 × 500 mm |
| Temperature Range | RT to 132°C |
| Humidity Range | 75–100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safe capacity 4.0 kg/cm² |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |