Generic
Filter
Showing 541–570 of 1032 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSystem 750 / 2000 / 4000 / 6000 |
| Price Range | USD $2,500 – $6,200 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | SC3/3, SC8/5, SC11/17, SC16/11, SC Millennium 20, SC20/20, SC33/26, SC36/32 |
| Price Range | USD $1,400 – $2,800 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVE XC |
| Price Range | USD $1,300 – $2,600 |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MYS-1 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N4R-1.0-50 |
| Price Range | USD 4,200–7,000 (FOB) |
| Water Flow Rate | 100–1000 L/h |
| Controllable Resistivity Range | 0.15–1.7 MΩ·cm |
| Control Accuracy | ±0.03 MΩ·cm |
| Max. Inlet Water Pressure | 0.5 MPa |
| Pressure Drop | 0.06 MPa at 3000 L/h |
| Connection Ports | 3/4″ female screw |
| Power Supply | AC 100–130 V / 220–240 V, 50/60 Hz, single-phase, 1 A |
| Enclosure Type | Rack or Cabinet |
| H₂O₂-Compatible Sterilization | Yes (3% hydrogen peroxide) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N9040B UXA X-Series |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | N962A |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Accuracy | ≤ ±5% |
| Operating Temperature | 0–40 °C |
| Operating Relative Humidity | 0–85% RH |
| Measurement Range | 0–30 m/s (auto-ranging across 0–10 / 0–20 / 0–30 m/s) |
| Power Supply | Rechargeable Ni-MH Battery (memory-free) |
| Display | Large-format LED |
| Sensor Element | Thin-film Platinum RTD (ceramic substrate) |
| Compliance | Designed for GLP-aligned field use in occupational & environmental monitoring |
| Origin | Germany |
|---|---|
| Type | Box-Type Muffle Furnace |
| Max Operating Temperature | 1400 °C / 1500 °C / 1600 °C |
| Temperature Uniformity | ±1 °C |
| Heating Element | Silicon Carbide (SiC) Rods |
| Internal Chamber Dimensions | 170 × 290 × 170 mm |
| Max Power Input | 13.0 kW |
| Ramp Time to Max Temperature | ≤45 min |
| Construction | Dual-Wall Stainless Steel Housing with Ceramic Fiber Insulation |
| Compliance | EN 60519-2 (Thermal Protection Class 2), CE Marked |
| Origin | Germany |
|---|---|
| Type | Box-type Muffle Furnace |
| Max. Temperature | 1200 °C |
| Temperature Uniformity | ±1 °C |
| Heating Method | Embedded Resistance Wire in Ceramic Heating Panels |
| Internal Volume | 1–40 L |
| Power Rating | 1.2–6 kW |
| Ramp Time to Max Temp | ≤30 min |
| Construction | Double-walled Stainless Steel (V2A) Housing with Vacuum-Insulated Fiber Modules |
| Door Options | Flip-up or Lift-up Configuration |
| Safety Compliance | EN 60519-2, Thermal Protection Class 2 |
| Software Control | Compatible with Controltherm MV Process Management Suite |
| Origin | Germany |
|---|---|
| Type | Box-Type Muffle Furnace |
| Max. Temperature | 1100 °C or 1200 °C |
| Temperature Accuracy | ±1 °C |
| Max. Power | 6 kW |
| Heating Rate to Max. Temperature | ≤40 min |
| Heating Method | Dual-Side Ceramic Heating Plates (Triple-Side for L24/11–LT40/12 models) |
| Internal Volume | 1–40 L |
| Compliance | EN 60519-2, IEC 61000-6-3, CE Marked |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N 30/45H |
| Instrument Type | Box-Type Muffle Furnace |
| Max. Operating Temperature | 450 °C |
| Temperature Uniformity | ±3 K (within working chamber, per DIN 17052-1) |
| Control Accuracy | ±1 °C |
| Max. Power Consumption | 9 kW |
| Heating Rate to Max. Temp. | ≤30 min |
| Heating Element | Resistance Wire (NiCr Alloy) |
| Internal Chamber Volume Options | 5–500 L |
| Construction | Stainless Steel Inner Chamber (AISI 304), Reinforced Insulation, Horizontal Air Circulation System |
| Compliance | DIN 17052-1, EN 61000-6-3, EN 61000-6-4 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | N 7/H – N 87/H |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1280 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 20 kW |
| Ramp Time to Max Temp | 120 min |
| Heating Configuration | Triple-Sided (Left, Right & Bottom) |
| Internal Volume | 7–61 L |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R 50/250/12 |
| Instrument Type | Tube Furnace |
| Max Temperature | 1200 °C or 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 6.5 kW |
| Heating Time to Max Temp | 60 min |
| Heating Method | Resistance Wire |
| Tube Outer Diameter Range | 50–120 mm |
| Electrical Supply | 1-phase or 3-phase, depending on model |
| Weight | 20–230 kg (model-dependent) |
| Compliance | EN 60519-2 (thermal protection class 2), CE-marked |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHTC 80-230/15 / RHTC 80-710/15 |
| Temperature Range | Up to 1500 °C |
| Temperature Uniformity | ±10 K over specified hot zone length |
| Control Accuracy | ±1 °C |
| Heating Method | Silicon Carbide (SiC) Rod Heaters |
| Maximum Power | 11.7 kW |
| Chamber Inner Diameter | 80 mm |
| External Dimensions (W×D×H) | up to 1070×430×580 mm |
| Weight | up to 90 kg |
| Electrical Supply | 3-phase, 400 V AC |
| Thermal Insulation | High-performance ceramic fiber module system |
| Safety Compliance | EN 60519-2 Class 2 Overtemperature Protection |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | RS 80/300/11 – RS 170/1000/13 |
| Heating Method | Resistance Wire |
| Max Temperature | 1100 °C or 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 12.6 kW |
| Internal Tube Diameter | 80 mm to 170 mm |
| Standard Tube Material | C 530 (Alumina-Rich Ceramic, Suitable for Air Atmosphere) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ViscoLiner |
| Price Range | USD 14,000 – 70,000 |
| Measurement Range | 0.1–1,000,000 cP |
| Temperature Range | −40 °C to +450 °C |
| Max Pressure Rating | 350 bar |
| Repeatability | ±0.25% |
| Accuracy | ±2% |
| Response Time | 1 s |
| Integrated Temperature Sensor | PT100 RTD |
| Temperature Compensation | Yes |
| Flow-Immune Measurement Principle | Vibrational Resonance |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P130 / S130 |
| Price Range | USD 280,000 – 420,000 |
| UV Light Source | 405 nm LED |
| XY Resolution | 2–10 µm |
| Layer Thickness | 5–20 µm |
| Build Volume (P130) | 3.84 × 2.16 × 10 mm (Mode 1) / 38.4 × 21.6 × 10 mm (Mode 2) / 50 × 50 × 10 mm (Mode 3) |
| Build Volume (S130) | Up to 100 × 100 × 50 mm |
| Optical System | High-NA Projection Micro-Lithography Optics |
| Post-Processing | Integrated Vacuum Despersion + UV Curing Station |
| Power Requirement | 200–240 V AC, 50/60 Hz, 3 kW |
| Weight | 450 kg |
| Dimensions | 1720 × 650 × 1820 mm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | NeoSpectra Micro |
| Price | USD 1,400 (FOB) |
| Wavelength Range | 1250–2500 nm |
| Optical Resolution (FWHM @ 1550 nm) | 8 nm or 16 nm |
| SNR (2-s scan, 16-nm res.) | 1000:1 @ 2050 nm |
| Operating Temperature | −5 to +40 °C |
| Wavelength Accuracy | ±1.5 nm @ 1400 nm (<40 °C) |
| Wavelength Repeatability | ±0.1 nm @ 1400 nm, 0.5 A.U., 16-nm res. |
| PSD Sensitivity Threshold | > max PSD/10 |
| Configuration | Reflectance (Rx) or Transmission (Tx) compatible |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LFR MOD 4EC |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Type | Telescope-Style Laser Rangefinder |
| Operating Principle | Pulsed Time-of-Flight Laser Ranging |
| Measurement Range | 16 – 4000 m |
| Distance Accuracy | ±1 m |
| Telescope Magnification | 7× (fixed optical path, optimized for long-range target acquisition) |
| Integrated Sensor Outputs | Distance, Azimuth (0–6400 mils / 360°), Elevation Angle (±60°), and Velocity (derived via sequential ranging) |
| Environmental Rating | IP66/IP67 |
| Laser Class | Class 1 (IEC 60825-1:2014) |
| Wavelength | 905 nm |
| Beam Divergence | 1 mrad |
| Response Time | 0.5 s |
| Power Supply | 9 V DC (standard alkaline or rechargeable battery pack) |
| Shock & Vibration Resistance | MIL-STD-810G compliant |
| RF Immunity | EN 61326-1:2013 compliant |
| Operating Temperature | −30 °C to +60 °C |
| Dimensions | 230 × 210 × 95 mm |
| Weight | 2.6 kg |
| Interface | RS-232 (asynchronous, 9600 bps default, configurable) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGC 8200 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | No.214 |
| Quotation | Upon Request |
| Standards Compliance | ASTM D2863, ISO 4589-2, JIS K6269 & K7201 |
| Combustion Column ID | φ75±3 mm (standard), φ95 mm (optional) |
| Height | 450±5 mm |
| Gas Flow Control | Dual digital mass flow meters (O₂ & N₂) |
| Pressure Monitoring | O₂/N₂ supply pressure gauges + leak detection port |
| Ignition Source | Adjustable propane or pipeline gas burner (flame length 6–25 mm) |
| Sample Holder | U-shaped stainless steel fixture |
| Sample Types | Rigid/flexible plastics, elastomers, rubber compounds, textile fibers, and laminates |
| Power Supply | AC 100 V, 1-phase, 3 A, 50/60 Hz |
| Dimensions (W×D×H) | Approx. 600 × 290 × 660 mm |
| Weight | Approx. 30 kg |
| Key | Temperature Range: +100°C to +132°C (saturated steam temperature) |
|---|---|
| Humidity Range | 75–100% RH (saturated steam) |
| Pressure Control | 0–6 kgf/cm² (PID-controlled, computer-integrated) |
| Operating Pressure | 2.0 kgf/cm² (rated for ≥6 atm burst pressure) |
| Pressure Ramp Time | ≤45 min (0 → 2.0 kgf/cm²) |
| Temperature Control | PID microprocessor-based (VT-4810 controller), RT+10°C to 200°C, K-type thermocouple input, SSR solid-state relay output |
| Steam Circulation | Natural convection of saturated water vapor |
| Test Duration | 0.00–999.99 hr |
| Safety Interlocks | Dual-pressure/temperature sensing, vacuum-assisted air purge, auto-depressurization, auto-vacuum break, auto-refill (up to 1000 hr continuous operation) |
| Compliance | ASTM D2247, DIN 50017, ISO 6270-2, IEC 60068-2-30, NACE TM0177, UL 746C, JIS Z 2243, MIL-STD-810H Method 507.6 |
| Sample Access | Horizontal cylindrical chamber with radial door latch, self-sealing under internal pressure |
| Key | Temperature Range: +100°C to +132°C (saturated steam temperature) |
|---|---|
| Humidity Range | 75–100% RH (saturated steam) |
| Pressure Control | 0–6 kg/cm² via PID-based digital pressure controller |
| Operating Pressure | 2.0 kg/cm² (≥6 atm burst rating) |
| Pressure Ramp Time | ≤45 min (0 → 2.0 kg/cm²) |
| Temperature Control | PID microprocessor with PV/SV dual display, K-type thermocouple input, SSR solid-state relay output, RT+10°C to 200°C range |
| Steam Circulation | Natural convection of saturated steam |
| Timer Range | 0.00–999.99 hr |
| Chamber Geometry | Horizontal cylindrical inner chamber with vacuum-sealed door interlock |
| Safety System | Dual-locking pressure/temperature interlock, automatic depressurization, vacuum purge, and auto-refill (up to 1000 hr continuous operation) |
| Compliance | ASTM D2247, DIN 50017, ISO 6270-2, IEC 60068-2-30, UL 746C, MIL-STD-810H, JIS Z 2243, NACE TM0177, BS EN 60068-2-30 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N25E-SWIR |
| Price | Upon Request |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 10 nm |
| Spectral Sampling Interval | 6.3 nm |
| Effective Slit Length | 9.6 mm |
| Optical Throughput Efficiency | >50% |
| Relative Aperture | f/2.0 |
| Slit Width | 30 µm |
| Stray Light Level | 0.5% |
| Detector Type | Mercury Cadmium Telluride (MCT) |
| Detector Cooling | Thermoelectric (TE) |
| Full-Frame Pixel Count | 320 × 256 (240 active rows) |
| Pixel Size | 30 × 30 µm |
| A/D Output | 14-bit |
| Dynamic Range | 800:1 |
| Frame Rate (Full Frame) | 100 fps |
| Exposure Time Range | 0.1–20 ms |
| Computer Interface | LVDS |
| Lens Mount | C-Mount |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nordson Dage Quadra™ 5 |
| Price Range | USD $130,000–$195,000 (est.) |
| Instrument Type | Scanning X-ray System |
| X-ray Tube Power | ≤10 W (0.35 µm spot size), ≤20 W (0.95 µm spot size) |
| X-ray Source | QuadraNT™ Sealed Transmission Tube |
| Detector | AspireFP™ Flat-Panel Detector |
| Integrated Micro-CT Stage | Yes |
| Thermal Stage for Reflow Simulation | Yes |
| Compliance Standards | IPC-A-610, IPC-7095, ISO/IEC 17025 (for lab accreditation), FDA 21 CFR Part 11 (software audit trail enabled) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NRF31 |
| Pricing | Available Upon Request |
| Detection Radiation Types | Gamma (γ) and X-rays, Neutrons |
| Detector Technology | Silicon Semiconductor |
| Dose Equivalent Range | 1 μSv – 9.999 Sv (0.1 mrem – 999.9 rem) |
| Accuracy | ±10% for γ/X-rays (0.1 mSv – 9.999 Sv, ¹³⁷Cs) |
| Energy Range | γ/X-rays: 35 keV – 6 MeV |
| Neutrons | 0.025 eV – 15 MeV |
| Energy Dependence | ±20% (γ/X), ±50% (neutrons) |
| Angular Dependence | ±20% (γ/X), ±30% (neutrons) |
| Battery Life | >1 year (8 h/day usage) or >4 months (continuous operation) |
| Dimensions | 60 W × 78 H × 33 D mm |
| Mass | ~125 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | O3-LIDAR |
| Laser Source | Nd:YAG-based UV laser system (266 nm fundamental, 289 nm & 316 nm Raman-shifted) |
| Detector | High-quantum-efficiency photomultiplier tubes (PMTs) with solar-blind UV response |
| Operating Wavelengths | 289 nm and 316 nm (DIAL pair) |
| Maximum Detection Altitude | Up to 25 km (dependent on atmospheric conditions) |
| Pulse Repetition Frequency | 20–50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blue Series |
| Spectral Range | 200–1100 nm |
| Detector | CCD (2048-pixel linear array) |
| Optical Resolution (FWHM) | 0.13–6.0 nm (dependent on grating and slit configuration) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well, 1 s integration) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | <0.1% at 435 nm |
| Interface | USB 2.0, SMA905 fiber input, 16-bit ADC |
| Integration Time | 1 ms – 65 s |
| Grating Options | 300–2400 g/mm (holographic & ruled) |
| Slit Options | 14–200 µm |
| Focal Ratio | f/4 |
| Optical Design | Symmetric Czerny–Turner with crossed-beam geometry |
| Power Supply | <100 mA via USB port |
| Dimensions | 25.4 × 76.2 × 127 mm (1 × 3 × 5 in) |
| Weight | 397 g (14 oz) |
| Table Top Dimensions | 200 × 200 mm |
|---|---|
| Maximum Load Capacity | 10 kg |
| Pulse Duration Range | 0.6–20 ms (programmable, automatic) |
| Peak Acceleration Range | 150–20,000 m/s² |
| Pulse Waveform | Half-sine |
| Impact Direction | Vertical |
| Secondary Impact Prevention | Hydraulic–friction braking system |
| Height Adjustment | Digital preset + hydraulic lifting |
| Control & Measurement System | Integrated shock analysis unit |
| Table Mass | 2800 kg |
| Overall Dimensions | 750 × 2600 × 1000 mm |
| Power Supply | AC 380 V ±10%, 50 Hz, 3 kVA |