| [Origin | Hebei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-9860 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +5 °C to 450 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C → 50 °C (ambient-assisted) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Installation Span | 152.4 mm (6-inch standard) |
| Oven Temperature Stability | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% (100–350 °C) |
| Programmable Temperature Ramps | 8-step linear |
| Maximum Run Time | 6000 min |
| Dimensions (L×H×W) | 520×480×500 mm |
| Net Weight | 50 kg |
| Power Requirement | 220 V ±10%, 2500 W] |
| [Origin | Hebei, China |
|---|---|
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C → 50 °C |
| Carrier Gas Flow Control | 0–1200 mL/min |
| Carrier Gas Pressure Control | 0–970 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| Column Compatibility | Packed (3–5 mm OD) & Capillary (6-inch standard interface) |
| Dimensions (L×H×W) | 520×480×500 mm |
| Weight | 50 kg |
| Power | 2500 W |
| Voltage | 220 V ±10% |
| Temperature Stability | ±0.1 °C |
| Programmable Steps | 8-stage linear ramp |
| Max Run Time | 6000 min |
| Detector Support | Up to 4 simultaneous (FID/TCD/ECD/NPD/FPD), configurable in series or parallel |
| Data Storage | 20 method sets with full chromatogram recall |
| Display | 5.7″ LCD (320×240), bilingual Chinese/English UI] |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | EDX 8000H |
| Configuration | Benchtop/Floor-Standing |
| Industry-Specific Use | Electronics & RoHS Compliance |
| Elemental Range | Na (11) to U (92) |
| Quantitative Range | 1 ppm to 99.99 wt% |
| Energy Resolution | 149 ± 5 eV (Mn Kα) |
| Repeatability | RSD ≤ 0.05% (at 100 s counting time, certified reference materials) |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–70% RH |
| Power Supply | AC 220 V ± 5 V, 50 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic (PRC) |
| Model | FJ-403GI |
| Pricing | Upon Request |
| Measurement Quantity | Personal Dose Equivalent Hp(10) |
| Dose Range | 0.01 µSv – 9999 mSv |
| Dose Rate Range | 0.1 µSv/h – 200 mSv/h |
| Communication Interface | Infrared (IR) Data Transfer |
| Power Supply | Two AA 1.5 V alkaline batteries or one 3.6 V high-energy lithium battery |
| Battery Life | Up to 1000 hours (at background radiation, 1.5 V) |
| Data Storage Capacity | 160 dose history records (time-stamped, auto-logged) |
| Alarm Functions | Configurable dose rate threshold, cumulative dose threshold, and incremental dose audio alert |
| Compliance | Calibrated to ICRP-defined Hp(10) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | Beilao-20 |
| Price | USD 570 (approx.) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2.5 |
| Price Range | USD 14,000–21,000 |
| Measurement Principle | Laser Light Scattering |
| Measured Parameters | PM10 and PM2.5 mass concentration |
| Measurement Range | 0.001–10 mg/m³ or 0.001–100 mg/m³ |
| Sampling Flow Rate | 2.83 L/min ±2% |
| Detection Limit | 2 µg/m³ |
| Minimum Resolution | 0.001 mg/m³ |
| Parallelism | ≤5% |
| Data Reporting Interval | 1–9999 s |
| Display | Real-time LCD screen |
| Calibration Method | NIST-traceable standard membrane |
| Communication Interface | RS232 with synchronized data streaming |
| Environmental Compensation | Automatic humidity correction |
| Compliance Standards | GB 5748-85, WS/T 206–2001, LD 98–1996, GBZ 2–2002, GBZ 159–2004 |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TOP RAY 160 |
| Pricing | Available Upon Request |
| Maximum Sample Capacity | 160 g |
| Readability | 0.001 g |
| Repeatability | ±0.0005 g |
| Moisture Range | 0.01–100.00% (w/w) |
| Temperature Range | 50–160 °C (adjustable in 1 °C increments) |
| Heating Source | Dual Heraeus quartz halogen lamps |
| Heating Chamber Material | Full stainless steel (AISI 304) |
| Power Supply | 230 V ±15%, 50/60 Hz |
| Drying Accuracy | ±1% (relative to reference method, e.g., Karl Fischer or loss-on-drying per ASTM E1868) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 737 / 737R |
| Quotation | Available upon Request |
| Temperature Range (737) | Ambient +5°C to 80°C |
| Temperature Range (737R) | 4°C to 80°C |
| Temperature Control | Microprocessor-based, non-programmable |
| Temperature Display | Digital LED, 0.1°C resolution |
| Temperature Accuracy | ±0.15°C |
| Temperature Uniformity | ±0.2°C across chamber |
| Speed Range | 20–420 rpm (configurable beyond standard range) |
| Orbit Diameter | 20 mm |
| Drive Mechanism | Dynamically balanced three-axis eccentric drive |
| Safety Interlock | Motor stops automatically when chamber door is opened |
| Chamber Material | Powder-coated stainless steel |
| Shelf Compatibility | Stackable, optional shelving kits available |
| Platform Dimensions (W×D) | 520 × 451 mm |
| Chamber Dimensions (W×D×H) | 615 × 520 × 595 mm (737), 615 × 520 × 755 mm (737R) |
| External Dimensions (W×D×H) | 845 × 600 × 850 mm (737), 845 × 600 × 1010 mm (737R) |
| Net Weight | 113 kg (737), 124 kg (737R) |
| Shipping Weight | 164 kg (737), 173 kg (737R) |
| Flask Capacity Support | 50–6000 mL |
| Max Flask Load per Platform | 72 × 50 mL, 42 × 125 mL, 25 × 250 mL, 16 × 500 mL, 9 × 1000 mL, 6 × 2000 mL, 4 × 2800 mL, 4 × 4000 mL, 2 × 6000 mL |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BD2000 |
| Pricing | Available Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Genesis ALD |
| Substrate Width | Up to 420 mm |
| Process Temperature | Up to 250 °C |
| Precursor Channels | Configurable (standard ≥4) |
| ALD Film Thickness Range | Up to 100 nm |
| Dynamic Deposition Rate (Al₂O₃) | 10 nm·m/min |
| Uniformity | ≤±1.5% (3σ, across full web width) |
| System Footprint | Customizable per integration requirements |
| Weight | Site-specific (typically 1,200–2,500 kg) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HP100 |
| Price Range | USD 700–1,400 |
| Heating Power | 1000 W |
| Max Operating Temperature | 300 °C |
| Display | 7-inch Full-Color TFT Touchscreen |
| Heating Surface Dimensions | 203 mm × 203 mm (8 inch × 8 inch) |
| Temperature Control Resolution | 0.1 °C |
| Temperature Stability | ±0.5 °C |
| Programmable Lift Mechanism | 5-step, 0–30 mm travel (0.1 mm resolution) |
| Timer Range | 0.1 s to 100,000 s |
| Program Storage | 100 user-defined recipes (5 steps each) |
| Construction | Corrosion-resistant hard-anodized aluminum top plate |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SC100D |
| Price Range | USD 1,400 – 2,800 |
| Max. Rotation Speed | 0–10,000 rpm |
| Speed Resolution | 1 rpm |
| Timing Resolution | 0.1 s |
| Acceleration Range (no-load) | 10–50,000 rpm/s |
| Maximum Substrate Diameter | 203 mm (8-inch wafer) |
| Chamber Diameter | 203 mm |
| Programmable Recipes | 100 recipes × 100 steps |
| Max. Process Duration | 3000 s |
| Control System | Industrial PLC with servo motor drive |
| HMI | 7-inch full-color capacitive touchscreen |
| Chamber Material | HDPE inner cavity |
| Enclosure | Stainless steel (SUS304) |
| Viewing Window | Solvent-resistant polycarbonate (PC) |
| Spray System | Quadruple independent nozzle array (developer, DI water, optional process chemicals) |
| Compliance | Designed for Class 1000 cleanroom-compatible operation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Bettersize2000 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.02–2000 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | ≤10 s per run |
| Laser Source | Imported fiber-coupled semiconductor laser (lifetime ≥25,000 h) |
| Optical System | Dual-lens design with auto-alignment |
| Detector Array | 90-element high-sensitivity photodiode array |
| Ultrasonic Power | 50 W |
| Circulation Tank Volume | 600 mL |
| Flow Rate | 3000–8000 mL/min |
| Operating System Compatibility | Windows XP/7/8/10 |
| Interface | USB 2.0/3.0 |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions & Weight | 800 × 500 × 410 mm, 45 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFT |
| Pricing | Available Upon Request |
| Compliance | ASTM D4151 |
| Construction | Stainless Steel Enclosure with Tempered Glass Viewing Window |
| Ignition Source | No. 18 Needle Burner (Adjustable Flame Height) |
| Timing Resolution | 0.01 s |
| Accessories | Standardized Brushing Device, Sample Holder Assembly, Stainless Steel Specimen Clamps |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XG5010 |
| Price Range | USD 28,000 – 70,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Radiation Dose Rate & Spectral Analyzer |
| Energy Resolution | <65% FWHM @ 5.16 keV (²³⁹Pu) |
| Energy Linearity | ≤±1% (60 keV–2.0 MeV) |
| Long-Term Stability | ≤±1% over 8 h |
| Operating Temperature | +5°C to +35°C |
| Relative Humidity | ≤80% at 30°C |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Detector | φ40 mm × 1 mm Si-PIN X-ray detector |
| Interface | RS-232 serial communication |
| Software | PHA18 Pulse Height Analysis software (Windows 98 compatible) |
| Quality System | ISO 9001 certified |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | FJ428G |
| Instrument Category | Dosimeter / Dose Rate Meter |
| Instrument Type | Portable |
| Measured Medium | Air |
| Detector Type | Environmental Radiation Detector |
| Radiation Type | X and γ |
| Measurement Range | (1–10,000) × 10⁻⁸ Gy/h |
| Accuracy | ±10% reading error |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1000IIA2 |
| Price | USD 4,200 (FOB) |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1200 × 780 × 1950 mm |
| Internal Work Area (L×W×H) | 1000 × 700 × 680 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm (EN 1822-1 |
| Inflow Velocity | 0.35 ± 0.025 m/s |
| Downflow Velocity (Center) | 0.26 ± 0.025 m/s |
| Downflow Velocity (Rear) | 0.27 ± 0.025 m/s |
| Side Airflow Velocity | 0.38 ± 0.025 m/s |
| Air Leakage Rate | ≤1×10⁻⁶ m/s @ 500 Pa |
| Sound Pressure Level | ≤62 dB(A) |
| Vibration Amplitude (Half-Peak) | ≤5 µm |
| Illumination | ≥300 lux |
| Power Supply | AC 220 V, 50 Hz, Single Phase |
| Power Consumption | 0.6 kW |
| Net Weight | <200 kg |
| HEPA Filter Size & Qty | 995 × 600 × 38 mm × 1 |
| Fluorescent Lamp / UV Lamp | 20 W × 1 / 20 W × 1 |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BHC-1300IIA/B3 |
| Instrument Class | Class II A2 Biological Safety Cabinet (30% Exhaust) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity (Center) | 0.27 m/s |
| Inflow Velocity | ≥0.5 m/s |
| Noise Level | ≤58 dB(A) |
| Power Consumption | 2.1 kW |
| Weight | 340 kg |
| Lighting | 30 W × 2 Fluorescent Lamps + 30 W UV Lamp |
| Illumination | ≥650 lx |
| Airflow Configuration | Left/Right/Top Exhaust Options |
| Certified Protection Levels | Personnel Protection (≤10 CFU/plate, impact sampler), Product Protection (≤5 CFU/plate), Cross-Contamination Protection (≤2 CFU/plate) |
| Compliance | Meets ISO 14644-1 Class 5 (ISO Class 5, formerly “100”), EN 12469:2000, and GB/T 16292–16294 (Chinese Pharmacopoeia & GMP requirements) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-Made) |
| Model | BHC-1300IIA2 |
| Cabinet Type | Class II, Type A2 (30% Exhaust / 70% Recirculated) |
| External Dimensions (L×W×H) | 1500 × 815 × 2270 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.33 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Lighting Intensity | ≥650 lux |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 2.0 kW (including dedicated GFCI outlets) |
| Net Weight | 340 kg |
| Lighting | Two 30 W fluorescent lamps + one 20 W UV lamp |
| Exhaust Options | Left, right, or top discharge |
| User Capacity | Dual-operator configuration |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Class II, Type B2 (Total Exhaust) Biosafety Cabinet |
| Model | BHC-1300IIB2 |
| External Dimensions (L×W×H) | 1525 × 830 × 2300 mm |
| Internal Work Area Dimensions (L×W×H) | 1300 × 600 × 640 mm |
| Filter Efficiency | HEPA ≥99.995% @ 0.3 µm |
| Downflow Velocity | 0.30 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Total Power Consumption | 2.0 kW (including auxiliary socket) |
| Weight | 340 kg |
| Lighting | 2 × 36 W fluorescent lamps |
| UV Lamp | 1 × 30 W |
| Illuminance | ≥650 lx |
| Duct Port Diameter | Ø250 mm |
| Safety Certification Compliance | EN 12469:2000, NSF/ANSI 49-2022, GB 50346-2011 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | BHC336 |
| Pricing | Available Upon Request |
| Origin | Hebei, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | BHP9514 |
| Price | Upon Request |
| Sample Positions | 18 |
| Minimum Detection Time | 5 min |
| Detector Core | Photomultiplier Tube (PMT) |
| Spectral Detection Range | 300–650 nm |
| Display | LCD Touchscreen |
| Data Output | Built-in Micro Printer & PC Interface |
| Environmental Operating Range | 5–40 °C, 10–90% RH (at 25 °C) |
| Toxicity Indicator | LED Status Lights (Pass/Fail) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BHY-FIR1118 |
| Pricing | Available Upon Request |
| Operating Voltage | 220 V AC |
| Rated Power | 500 W |
| Chamber Dimensions | 400 × 260 × 220 mm (L × W × H) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BHY-FM100 |
| Pricing | Available Upon Request |
| Maximum Sample Load per Vial | 1/3 of Vial Volume |
| Feed Size | <10 mm |
| Final Particle Size | Down to 0.1 µm |
| Oscillation Frequency | 1200 cycles/min |
| Timer Range | 0–72 h |
| Voltage/Power | 220 V AC / 200 W |
| Input Frequency | 50 Hz |
| Dimensions (W×D×H) | 450 × 375 × 280 mm |
| Weight | 18 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BI-2500 |
| Detection Range | <100 Da, KD = 10⁻³ M (1 mM) to 10⁻¹² M (1 pM), angular resolution <10⁻⁴° |
| Sample Channels | 3 |
| Injection Volume | >50 µL |
| Analysis Time Scale | milliseconds to hours (kinetically resolved) |
| Temperature Control | Ambient only |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BI-4500 |
| Price Range | USD 70,000 – 140,000 |
| Sample Flow Channels | 5 |
| Light Source | Dual 670 nm LEDs |
| Detection Speed | 4 ms |
| Incident Angle Range | 40–47° (gas phase), 67–81° (liquid phase) |
| Sensitivity | < 0.06 RU RMS (0.01 mdeg RMS) |
| Drift | ≤ 1 RU/hour (≤ 0.17 mdeg/hour) under ambient temperature drift < 1 °C/hour |
| Interface | USB 3.0 |
| Dimensions | 355 × 250 × 515 mm (W × H × D) |
| Weight | 11.5 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Binder ED, FD, FED, FP |
| Pricing | Available Upon Request |
| Chamber Volumes (ED) | 23 L, 53 L, 115 L, 240 L, 400 L, 720 L |
| Chamber Volumes (FD) | 23 L, 53 L, 115 L, 240 L |
| Chamber Volumes (FED/FP) | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range (ED) | Ambient +5 °C to 300 °C |
| Temperature Control Accuracy (ED) | ±1 °C |
| Timer Range | 0–99 h |
| Safety Class | DIN 12880, Dual-Stage Independent Overtemperature Protection |
| Ventilation | Rear 50 mm exhaust duct + front adjustable air damper |
| Standard Interior | Chrome-plated wire shelves (2 pcs) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Binder FDL, MDL |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Binder VD / VDL Series |
| Price | Upon Request |