Huakeyi
Filter
Showing all 11 results
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HK-7501 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Online Analyzer |
| Measurement Method | Nessler Reagent Spectrophotometry |
| Measurement Range | 0–10 mg/m³ (customizable) |
| Detection Limit | 0.05 mg/m³ |
| Zero Drift | ±1% FS/month |
| Cycle Time | 5 min |
| Heating Temperature | 180–240 °C |
| Sample Flow Rate | 4–5 L/min |
| Reagent Consumption | Nessler Reagent 1 L/month, Potassium Sodium Tartrate Solution 0.5 L/month |
| Ambient Temperature | −10 to 50 °C |
| Power Supply | AC 200–240 V |
| Power Consumption | ≤1 kW |
| Compressed Air | 0.6–0.8 MPa |
| Enclosure Dimensions | 850 × 600 × 1780 mm (L×W×H) |
| Analog Output | 1 channel (0–10 mA / 0–20 mA / 4–20 mA, isolated, max load 750 Ω) |
| Relay Outputs | 3 channels |
| Communication Interface | RS485 |
| Filtration Precision | 2 µm (metal-ceramic composite membrane) |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-258 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Sensor |
| Measurement Range | 0.00–200 µg/L |
| Accuracy | ±0.3% FS or 1 µg/L (whichever is greater) |
| Repeatability | 0.05% |
| Detection Limit | 0.1 µg/L |
| Resolution | 0.1 µg/L, 0.01 mg/L |
| Temperature Compensation Range | 0–50 °C (manual or automatic) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Response Time (T90) | ≤60 s at 25 °C |
| Power Supply | Built-in 3.7 V rechargeable Li-ion battery |
| Battery Life | ≥40 h per charge |
| IP Rating | IP68 |
| Dimensions (Transmitter) | 123 mm × 86 mm × 267 mm (L×W×H) |
| Weight (Transmitter) | 1.5 kg |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3140WSA |
| Pricing Range | USD 7,000–14,000 (FOB) |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Measurement Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg for 3–1000 µg H₂O |
| Minimum Dispensed Volume | 1 µL (via syringe) |
| Electrolytic Current Output | 0–400 mA |
| Electrolysis Rate | 2.2 mg/min (37 µg/s) |
| Power Consumption | 50 W |
| Operating Voltage | 100–240 VAC, 50/60 Hz |
| Dimensions | 400 × 260 × 240 mm (L×W×H) |
| Weight | 2.0 kg |
| Data Storage | 500 timestamped records with searchable filters (date range, sample ID) |
| Connectivity | Standard USB 2.0, RJ-45 Ethernet port |
| Display | 800×480 color TFT-LCD touchscreen with bilingual (English/Chinese) UI |
| Stirring Speed | 5 adjustable levels |
| Safety & Diagnostics | Real-time electrode open/short circuit detection, blank current auto-compensation, endpoint drift correction, overcurrent/overheat protection |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-5810 |
| Price Range | USD 14,000 – 70,000 |
| Sample Processing | Waste Water Treatment |
| Regeneration Capacity | 8–20 L per cycle |
| Regeneration Efficiency | ≥98% for virgin cation resin |
| Acid Consumption (5% HCl) | ≤60 L/cycle |
| Rinse Water Consumption | ≤120 L/cycle |
| Cycle Time | ~3 hours |
| Construction Materials | Stainless steel frame, transparent organic glass columns, PVC piping |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 200–220 V |
| Dimensions (L×W×H) | 660 × 570 × 1480 mm |
| Weight | 100 kg |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-6010 |
| Measurement Range | pH 2.00–11.00 |
| Temperature Range | 0.00–99.9 °C |
| ATC Range | 0.1–60 °C |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.1 pH |
| Temperature Accuracy | ±0.5 °C |
| Output Signals | Isolated 0–10 mA / 0–20 mA / 4–20 mA (±1% FS) |
| Sample Temp. | 5.0–50.0 °C |
| Max. Sample Pressure | <0.6 MPa |
| Ambient Temp. | 5–50 °C |
| Humidity | ≤95% RH |
| Dimensions (Enclosure) | 300 mm × 400 mm × 200 mm (W×H×D) |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | ≤40 W |
| Dielectric Strength | 1500 VAC for 1 min |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-7100A / HK-7101 |
| Instrument Type | Fixed Online Gas Detector |
| Detectable Gases | CH₄, CO₂, HC (hydrocarbons), and other combustible/toxic gases |
| Measurement Principle | Infrared (IR) and Catalytic Bead (Pellistor) |
| Response Time (T90) | ≤10 s (catalytic), ≤15 s (IR) |
| Accuracy | ±3% FS (full scale) |
| Measurement Range | CH₄: 0–100% LEL |
| CO₂ | 0–5000 ppm, 0–2%, 0–5%, or 0–100% vol (configurable) |
| Display | Dual-language OLED (Chinese/English) |
| Output Signal | 4–20 mA analog + optional RS485 Modbus RTU |
| Power Supply | DC 18–30 V (bus- or zone-powered) |
| Enclosure Rating | IP66 |
| Operating Temperature | −40 °C to +70 °C |
| Explosion Protection | Ex d II C T6 Gb |
| Compliance | GB 15322.1–2003 |
| Wiring | 3-wire or 4-wire |
| Power Consumption | ≤5 W |
| Atmospheric Pressure Range | 86–106 kPa |
| Transmission Distance | 4–20 mA ≤1000 m (2.5 mm² cable) |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-7200A/7201 |
| Instrument Type | Fixed-mount (online) gas detector |
| Detectable Gases | HCN, CO, and other toxic gases |
| Response Time (T90) | ≤15 s |
| Measurement Accuracy | ±1% FS |
| Measurement Range | (0–100)% LEL |
| Detection Principles | Infrared (IR), Electrochemical (EC), Metal Oxide Semiconductor (MOS), Photoionization Detection (PID) |
| Display | Dual-language OLED (Chinese/English) |
| Output Signals | 4–20 mA analog + optional RS485 Modbus RTU |
| Power Supply | DC 18–30 V |
| Enclosure Rating | IP66 |
| Explosion Protection | Exd II CT6Gb |
| Compliance Standards | GB 15322.1–2003, GB 12358–2006 |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-8510 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry (in accordance with HJ/T 399–2007) |
| Wavelength | 600 nm |
| Measurement Range | 100–1000 mg/L (extendable to 10,000 mg/L via on-board dilution) |
| Accuracy | ±5% for COD > 50 mg/L |
| Repeatability | ±5% |
| Detection Limit | 0.1 mg/L |
| Analysis Time | 20 minutes per batch |
| Batch Capacity | 16 samples |
| Display | 7-inch capacitive touchscreen (Chinese/English switchable) |
| Data Storage | Up to 100,000 records (measurements, calibrations, system logs) |
| Interface | USB 2.0 for data export |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 10 W |
| Dimensions | 390 × 248 × 175 mm |
| Weight | 5 kg |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HK-8520 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Nessler Reagent Spectrophotometry (in accordance with HJ 535–2009) |
| Measurement Range | 0–50 mg/L NH₃–N (extendable to 60 mg/L via built-in dilution algorithm) |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±(5% of reading + 0.1 mg/L) |
| Repeatability | ±5% RSD |
| Measurement Time | 15–20 min per sample |
| Batch Capacity | 16 samples |
| Display | 7-inch capacitive touchscreen (Chinese/English switchable) |
| Data Storage | Up to 100,000 records (measurements, calibrations, system logs) |
| Interface | USB 2.0 for data export |
| Temperature Control | Integrated thermostatic cuvette chamber |
| Light Source | Imported monochromatic LED (peak wavelength ~420 nm) |
| Optical System | Patented dual-beam ratio-metric photometric path |
| Calibration Options | 1-, 2-, or multi-point calibration with user-defined standards |
| Auto-Stabilization Detection | Real-time signal convergence assessment |
| Dimensions | 390 × 248 × 175 mm |
| Weight | 5 kg |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | ≤10 W |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-8530 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Spectrophotometry (Diphenylcarbazide Method) |
| Target Analyte | Hexavalent Chromium (Cr(VI)) |
| Analysis Time | 20 min |
| Accuracy | ±5% of reading |
| Resolution | 0.001 mg/L |
| Detection Range | 0–50 mg/L (extendable to 60 mg/L via dilution) |
| LOD | 0.001 mg/L |
| Display | 7-inch TFT LCD touchscreen (Chinese/English switchable) |
| Temperature Control | Integrated thermostatic system |
| Light Source | Imported monochromatic LED (540 nm) |
| Calibration Options | Single-point, two-point, or multi-point |
| Data Storage | ≥100,000 records (measurements, calibrations, system logs) |
| Interface | USB port for data export |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 10 W |
| Dimensions | 390 × 248 × 175 mm |
| Weight | 5 kg |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-8610 |
| Price | Upon Request |
| Dimensions (Single-Channel) | 760 × 670 × 753 mm |
| Dimensions (Multi-Channel) | 1540 × 560 × 1360 mm |
| Input Voltage | 220 VAC, 50 Hz |
| Power Consumption | ≤180 W (Single), ≤300 W (Multi) |
| Touchscreen | 7-inch (Single), 10-inch industrial HMI |
| Turbidity Sensor Range | 0–100 NTU |
| Pressure Sensor Range | 0–1.6 MPa |
| pH Sensor Range | 0–14 |
| Filtration Volume Setting Range | 0–9999 L |
| Filtration Pump Flow Rate | 1.2 L/min |
| Sedimentation Processing Time (excl. settling) | ≤15 min per 10 L sample |
| Vacuum Pump Speed | 0–12 L/min, Ultimate Vacuum: 24 kPa |
| Recovery Rate | ≥30% |
| Microscope Optical System | VIS60 Infinity-Corrected, Parfocal Distance ≥60 mm |
| Stage Travel | 125 × 75 mm, Minimum Step: 0.1 µm |
| Fine Focus Resolution | 1 µm |
| Camera Resolution | 2448 × 2048 grayscale |
| DIC Compatibility | Yes |
| Expandability | Darkfield, Phase Contrast, Polarization, Multi-user Viewing |