LICA
Filter
Showing all 7 results
| Brand | LICA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LI-G2004 Ethylene Oxide Analyzer |
| Pricing | Available Upon Request |
| Measurement Principle | Cavity-Enhanced Absorption Spectroscopy (CEAS) |
| Detection Limit (C₂H₄O) | < 2 ppb (1σ, 1 sec) |
| H₂O Interference Limit | < 200 ppm (1σ, 1 sec) |
| Ethylene Oxide Range | 1 ppb – 1 ppm |
| Water Vapor Range | 500 – 30,000 ppm (non-condensing) |
| Data Output Rate | 1 Hz |
| Response Time | < 1 s (1/e) |
| Sample Flow Rate | 0.5 – 1 SLM |
| Operating Temperature | 0 – 45 °C |
| Operating Humidity | 0 – 98 %RH (non-condensing) |
| Inlet Fitting | ¼" Swagelok |
| Communication Interfaces | RS-232 serial, built-in Wi-Fi, Ethernet (RJ-45), USB-A, HDMI |
| Dimensions | 22" × 9" × 5.5" (56 cm × 23 cm × 14 cm) |
| Weight | 4 kg |
| Power Requirement | 14–36 VDC, 2.5 A |
| Power Consumption | < 30 W |
| Onboard Storage | 30 GB SSD |
| Calibration Method | Remote over Wi-Fi |
| Warranty | 12 months |
| Brand | LICA |
|---|---|
| Origin | Beijing, China |
| Model | 300-TC |
| Spectral Range | 400–1000 nm |
| Spectral Bands | 300 |
| Spatial Pixels per Line | 1200 |
| Max Frame Rate | 300 Hz |
| IMU Accuracy (Pitch/Roll) | <0.03° |
| IMU Accuracy (Heading) | <0.1° |
| IMU Output Rate | 1000 Hz |
| Weight | 400 g |
| Dimensions (L×W×H, w/o lens) | 110 × 75 × 70 mm |
| Power Consumption | 15 W |
| Platform Compatibility | DJI M300/M350 RTK drones with X-Port gimbal |
| Mounting Mass (system + gimbal) | ≤710 g |
| Brand | LICA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LI-2100 |
| Price | USD 30,500 (FOB Beijing) |
| Vacuum Level | <1000 Pa |
| Leak Rate | <1 Pa/s |
| Extraction Capacity | 14 samples per run |
| Throughput | >110 samples/day |
| Extraction Efficiency | >98% |
| Water Recovery Rate | 99–101% |
| Vacuum Pump | 5 L/min, 24 V DC, Max Pressure 5 mbar |
| Cooling | Compressor-coupled cryogenic trap, Min Temp −95 °C |
| Heating | Resistive cartridge heating, Max Temp 190 °C |
| Display | 7″ TFT LCD (800×480, 65K colors), touch-enabled HMI |
| Safety | Overtemperature cutoff, auto-alarm for cooling failure & vacuum breach |
| Dimensions (H×W×D) | 90 × 74 × 110 cm |
| Weight | 120 kg |
| Brand | LICA |
|---|---|
| Model | LI-G3001 |
| Measurement Targets | CH₄, CO₂, H₂O |
| Precision (1σ, 1 s / 10 s) | CH₄ < 2 ppb / < 1 ppb |
| Measurement Ranges | CH₄ 1–200 ppm |
| Operating Temperature | 0–45 °C |
| Operating Humidity | 0–95 %RH (non-condensing) |
| Data Acquisition Rate | ≥1 Hz (1/e response time) |
| Sample Flow Rate | 350 sccm |
| Power Consumption | < 30 W |
| Connectivity | Wi-Fi |
| Onboard Storage | 30 GB |
| Dimensions | 56 × 36 × 19 cm |
| Weight | 8 kg |
| Brand | LICA |
|---|---|
| Origin | Beijing, China |
| Model | LR1601 |
| Operating Principle | Push-broom |
| Platform Compatibility | Airborne & Ground-based |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.7 nm |
| Spectral Sampling Interval | 2.1 nm |
| Number of Spectral Bands | 561 (binning option: 281) |
| Spatial Pixels per Line | 1364 |
| Max Frame Rate | 249 fps |
| LiDAR Scan Rate | 320,000 pts/sec |
| Maximum Range | 150 m |
| Horizontal Accuracy | ±2 cm (1σ) |
| Vertical Accuracy | ±1 cm (1σ) |
| IMU Attitude RMS (Pitch/Roll) | 0.04° (PPK-aided) |
| GNSS Support | GPS, GLONASS, BeiDou, RTK |
| System Weight | 2.4 kg |
| Optional Sensors | RGB Camera, Thermal Imaging Camera |
| Brand | LICA |
|---|---|
| Model | PS-9000 |
| Measurement Principle | Dynamic Closed-Chamber Method (NDIR-based) |
| CO₂ Range | 0–6000 ppm |
| H₂O Range | 0–60000 ppm |
| Accuracy | <1% of reading |
| Repeatability | <1 ppm |
| Operating Temperature | −20 to +60 °C |
| Power Consumption | <40 W (controller), <2.2 W (SC-12N chamber) |
| Battery | 24 V / 8 Ah Li-ion |
| Runtime | 3–4 h per charge |
| Dimensions (controller) | 37 × 30 × 16 cm |
| Weight (controller, with battery) | 6.8 kg |
| Chamber Type | SC-12N portable soil respiration chamber |
| Chamber Area | 276.27 cm² |
| Chamber Volume | 3451 cm³ |
| Cable Length | 2 m |
| Soil Sensor | Volumetric Water Content (0.00–0.70 m³/m³ in mineral soils |
| 0.0–1.0 m³/m³ in substrates), Temp Range | −40 to +60 °C, Temp Accuracy: ±1 °C (−40 to 0 °C), ±0.5 °C (0 to 60 °C) |
| Communication | Wi-Fi, RS-232, SDI-12 |
| Data Storage | microSD card |
| Flow Rate | 3 L/min |
| Pump Supply | 12 V, <0.5 A |
| Brand | LICA |
|---|---|
| Model | PS-9600 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Simultaneous Target Gases | CH₄, CO₂, H₂O |
| Precision (1σ, 10 s / 100 s) | CH₄ ≤1.2 ppb / 0.6 ppb |
| Measurement Ranges | CH₄ 0–100 ppm (R² ≥ 0.9998) |
| Operating Temperature | −20 °C to +50 °C |
| Power Consumption | ≤35 W |
| Dimensions (Analyzer) | 55.38 × 35.5 × 19 cm |
| Weight (Analyzer) | 9 kg |
| SC-12 Chamber Dimensions | 27.5 × 24.5 × 44.5 cm |
| Chamber Footprint | 276.27 cm² |
| Chamber Actuation Time | ≤10 s |
| Chamber Weight | 4.05 kg |
| Data Storage | SD card |
| Communication Interfaces | RS-232, SDI-12, Wi-Fi |
| Battery | Dual rechargeable Li-ion packs included |
| Control Interface | Native Android/iOS mobile application |