Lovibond (Tintometer)
Filter
Showing 31–60 of 64 results
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model F |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Color Scale | Lovibond RYBN |
| Red Scale | 0.1–79.9 |
| Yellow Scale | 0.1–79.9 |
| Blue Scale | 0.1–49.9 |
| Neutral Scale | 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Illuminant Compliance | CIE Standard Illuminant C |
| Sample Chamber | Removable White Liner with Precision-Registered Cell Notch |
| Power Supply | External Low-Voltage DC Adapter |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Model F |
| Optical Principle | Visual color matching against calibrated glass color standards |
| Illumination | Standardized D65 daylight simulator with controlled viewing geometry |
| Viewing System | Dual-field comparator with fixed 45°/0° optical path |
| Sample Format | Liquid or semi-solid in standard 10 mm or 25 mm pathlength cuvettes |
| Compliance | ASTM D1500, ISO 2049, AOCS Cc 13b-92, IP 15, BS 684-2.17 |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | Model Fx (PFXeo) |
| Light Source | Tungsten-Halogen Lamp |
| Wavelength Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Spectrophotometric |
| Housing Material | Anodized Aluminum |
| Dimensions | 301 mm (W) × 152 mm (H) × 331 mm (D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing) |
| Storage Environment | −20–85 °C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Data Interfaces | USB, RS-232 |
| Certifications | CE |
| Supported Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Compliant Standards | ISO 15305, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, BS 684 Section 2.20, MS 252 Part 16, IP 17, GB/T 22460-2008, Lovibond® RYBN, Lovibond RY10:1 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model Fx |
| Price Range | USD 6,800 – 13,600 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | MODEL-F |
| Measurement Principle | Dual-field visual comparison against Lovibond® RYBN glass filter standards |
| Color Scale | Lovibond Red (R): 0.1–79.9, Yellow (Y): 0.1–79.9, Blue (B): 0.1–49.9, Neutral (N): 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Twin 12 V / 10 W tungsten-halogen lamps |
| Illumination | Daylight-mimicking (CIE Standard Illuminant C approx.) with integrated blue filter for spectral consistency |
| Optical System | Precision prism-based dual-view field with standardized viewing geometry |
| Sample Path Length | Adjustable from 0.1 to 153 mm (0.004 to 6 in) |
| Power Supply | 220 V AC / 12 V DC adapter |
| Dimensions & Weight | 330 × 410 × 230 mm |
| Certifications | CE compliant |
| Accessories | Interchangeable R/Y/B/N filter discs (e.g., Part Nos. 180200, 180300–180400), RYBN standard filter sets (184000–187000) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Product Type | Nesslerization-Compatible Glass Color Comparator Tubes |
| Model Designations | AF228, DB420, AF262, DB421, AF306, DB423, AF306/P, DB424/13.5 |
| Tube Format | Paired Sets (Matched Optical Path Length) |
| Material | Borosilicate Glass, ASTM E2020-22 Compliant |
| Nominal Path Length | 10 mm, 13.5 mm, 20 mm, 25 mm, 50 mm (Model-Dependent) |
| Calibration Traceability | NIST-Traceable Reference Standards Available |
| Compliance | ISO 7887, ASTM D1209, ASTM D5391, USP <631>, EN ISO 7887-2 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195 |
| Optical Configuration | 9-band interference filter photometer |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | Δx,y ≤ ±0.0004 |
| Measurement Time | <30 s |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–50 mm |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 VAC (external adapter) |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Calibration | One-touch automated baseline calibration |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions (W×D×H) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA, Gardner, Iodine, Saybolt, ASTM Color, FAC, EBC, ASBC, ICUMSA, Pfund, ADMI, EP, USP, CIE L*C*h, Hunter Lab, spectral reflectance/data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFXi195 Series |
| Price Range | USD 6,800 – 13,600 (FOB UK) |
| Light Source | Tungsten Halogen Lamp |
| Cell Material | Stainless Steel Cuvette Holder |
| Calibration | RCMSi-certified Verification Kit Included |
| Software | Windows-based Lovibond® ColorSoft v5.x |
| Compliance | ASTM D1209, D1500, D5386 |
| Data Interface | USB 2.0 |
| Display | Backlit LCD with On-Screen Guidance |
| User Access Control | Password-protected Admin Mode |
| Maintenance | Tool-free Cuvette Tray Removal & Lamp Replacement |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA (ASTM D1209), Gardner (ASTM D1544/D6166), Iodine (DIN 6162), CIE XYZ/Lab, Spectral Reflectance Data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Measurement Standards | Pt-Co/Hazen/APHA, Gardner, Iodine, CIE L*a*b*, CIE XYZ, Spectral Reflectance (360–780 nm) |
| Display | 7-inch TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO 9001, ISO/IEC 17025, ASTM D1209, ASTM D1500, ASTM D5386, ISO 6271, ISO 4630 |
| Data Management | GLP-compliant audit trail (date/time, operator ID, sample ID), internal storage for ≥10,000 results |
| Sample Handling | Removable stainless-steel cuvette holder, compatible with 10–50 mm pathlength glass or quartz cuvettes, optional flow-through cell |
| Enclosure | Powder-coated stainless-steel chassis with chemical-resistant surface finish |
| Software | Included ColorSoft™ PC software for spectral visualization, CIE chromaticity diagram plotting, deviation analysis (ΔE*ab, ΔL*, Δa*, Δb*), and custom standard creation |
| Remote Maintenance | RCMSi™ Remote Calibration & Monitoring System enabled |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), spectral reflectance (31-wavelength LED array) |
| Standards Supported | ASTM D1500 (Petroleum), ASTM D156 (Saybolt), ASTM D5386 (Color by Instrument), ISO 2764 (Pt-Co/Hazen/APHA), ISO 4630 (Gardner), CIE L*a*b*, CIE Yxy, ΔE*ab |
| Display | 7-inch TFT LCD with multi-language UI (including English, Chinese, Spanish, French, German) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥10,000 results with GLP-compliant audit trail (date, time, operator ID, sample ID, method ID) |
| Sample Compartment | Removable stainless-steel cell holder, compatible with 10–50 mm pathlength cuvettes (glass, quartz, disposable plastic) |
| Calibration | Factory-calibrated with NIST-traceable liquid standards |
| Enclosure | IP54-rated stainless-steel chassis with chemical-resistant coating |
| Software | Lovibond ColorControl v5.x (Windows), supports CIE chromaticity diagrams, spectral curve overlay, deviation analysis (ΔL*, Δa*, Δb*, ΔE*ab), custom standard creation, and 21 CFR Part 11–compliant user access control |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), Gardner, FAC, APHA/Pt-Co, Saybolt |
| Display | High-contrast backlit LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO/IEC 17025 traceable standards support (ASTM D1500, ASTM D6166, ISO 4630, ISO 27875, ISO 6271), GLP-compliant data logging |
| Sample Handling | Removable stainless-steel measurement cell, flow-through cuvette option available |
| Software | Included Lovibond Colour Control Software (Windows-compatible), CIE chromaticity diagram visualization, spectral reflectance/data export (CSV, XML), remote instrument control |
| Data Management | User ID, sample ID, timestamp, method ID, and deviation metrics (ΔE*, Δa*, Δb*, saturation ratio, hue angle offset) stored per measurement |
| Enclosure | Corrosion-resistant stainless-steel housing |
| Power | 100–240 V AC, 50/60 Hz |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/4 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), spectral reflectance/transmittance analysis |
| Standard Scales | EBC, ASBC, Gardner, Saybolt, Pt-Co (APHA), ISO 27677, ASTM D1209/D1500/D5386/D6166 |
| Display | Backlit LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Software | RCMSi Remote Calibration & Maintenance System, Lovibond Color Control Software v5.x |
| Compliance | ISO/IEC 17025 traceable calibration standards, ISO 9001-certified reference materials, GLP-compliant data logging (date/time/operator ID/sample ID) |
| Sample Handling | Removable stainless-steel cuvette chamber, compatible with 10–50 mm pathlength cells (standard and flow-through options) |
| Housing | Corrosion-resistant stainless steel chassis |
| Data Output | CSV, XML, PDF reports |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/5 |
| Compliance Standards | EP, USP, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data |
| Interface | USB & LAN (RCMSi Remote Calibration and Maintenance System) |
| Display | Large backlit LCD with multilingual UI (including Chinese) |
| Sample Holders | Compatible with multiple pathlength cuvettes (10–50 mm), optional flow-through cell |
| Construction | Stainless steel measurement chamber, chemical-resistant housing |
| Software | Included Color Control Software for spectral visualization, CIE chromaticity diagrams, data export, instrument remote control, GLP-compliant reporting |
| GLP Features | Date/time stamp, user ID, sample ID, audit trail, password protection |
| Customization | User-defined color standards, selectable display parameters, language selection, access-level passwords |
| Delta-E & Bias Analysis | Quantitative deviation reporting (ΔL*, Δa*, Δb*, ΔE*ab, hue angle, saturation ratio, bias factor) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D5386 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/6 |
| Measurement Principles | Absorption photometry at fixed wavelengths & full-spectrum reflectance/transmittance |
| Standard Methods Supported | Pt-Co/Hazen/APHA, Gardner, Saybolt, ASTM D1209, ASTM D5386, ISO 6271, ISO 2761, CIE L*a*b*, CIE XYZ, Klett (Blue Filter KS-42), Hess-Ives |
| Display | 7-inch high-resolution TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥2,000 measurements with GLP-compliant metadata (date/time, operator ID, sample ID, method ID) |
| Compliance | ISO/IEC 17025 traceable calibration standards available |
| Sample Format | Compatible with 10–50 mm pathlength glass or quartz cuvettes |
| Construction | Stainless steel optical chamber housing with chemical-resistant anodized aluminum chassis |
| Light Source | Long-life halogen tungsten lamp with stabilized power supply and automatic intensity compensation |
| Wavelength Range | 380–780 nm (full-spectrum mode) |
| Repeatability | ≤0.1 ΔE*ab (CIE 1976) for stable samples under controlled conditions |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/7 |
| Measurement Standards | ICUMSA, Pfund, Series 52 (Brown), CIE L*a*b*, Spectral Reflectance/Transmittance |
| Interface | USB & LAN |
| Display | Large backlit LCD |
| Language Support | Multilingual (including Chinese) |
| GLP Compliance | Date/Time stamp, Sample ID, Operator ID logging |
| Construction | Stainless steel measurement cell housing |
| Cell Compatibility | Standard cuvettes (10–50 mm pathlength), optional flow-through cell |
| Software | Included Lovibond Colour Control Software (CIE chromaticity diagrams, spectral data export, remote instrument control) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D1500, D5386 |
| Remote Maintenance | RCMSi Network Verification System |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/8 |
| Measurement Standards | ADMI, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data (380–780 nm, 10 nm intervals) |
| Display | 7-inch TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO 9001, ISO/IEC 17025 (via certified reference standards), ASTM D1209, ASTM D5386, ISO 6271, ISO 2211 |
| GLP Support | Date/time stamp, sample ID, operator ID, audit trail export |
| Sample Cell Compatibility | 10–50 mm pathlength cuvettes (rectangular, round, flow-through optional) |
| Housing | Stainless steel chassis with chemical-resistant anodized aluminum front panel |
| Calibration | RCMSi Remote Calibration Management System enabled |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interfaces | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 V AC (external adapter) |
| Housing | Steel with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heater | Up to 95 °C |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Software Features | GLP-compliant reporting, operator ID, sample ID, timestamp, RCMSi remote calibration and maintenance system |
| Built-in Color Scales | Lovibond RYBN, ASTM D1500, IP 17, ICUMSA, AOCS, Saybolt, CIE XYZ/xyY, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 / PFXi950 / PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Colorimetric Repeatability | Δx,y ≤ ±0.0002 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Filter Set | 16 Interference Filters |
| Data Storage Capacity | 100,000 Measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 Backlit LCD |
| Keypad | 23 Membrane Keys with Audible Feedback |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Power Supply | 90–240 V AC (External Adapter) |
| Dimensions | 515 × 196 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| GLP Features | Timestamped Audit Trail, User ID, Sample ID, Calibration Log |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 Automated Colorimeter |
| Optical Path Length | Up to 153 mm (6") |
| Compliance Standards | AOCS, ASTM D1500, ASTM D1209, ISO 2761, ISO 4630, ISO 6271, USP <631>, CIE 1931 & CIE 1976 (L*a*b*) |
| Data Interfaces | USB 2.0, 10/100 Mbps Ethernet (LAN) |
| Display | High-contrast backlit LCD with multilingual GUI (including English, German, French, Spanish, Chinese) |
| Software | Windows-based Lovibond ColorSoft v5.x with GLP audit trail, user management, and RCMSi remote calibration verification |
| Light Source | Tungsten-halogen lamp (replaceable) |
| Construction | Stainless steel housing with chemical-resistant coating |
| Optional Accessories | Integrated sample heater (for solid-to-liquid transition), custom filter sets, 1", 5.25", 10 mm, and 100 mm pathlength cells |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | RT700 |
| Measurement Principles | CIE-compliant 0°/d geometry (diffuse illumination, 0° viewing) |
| Illuminants | D65, A, C, F2, F7, F11 |
| Observer Angle | 2° and 10° standard observer |
| Color Spaces | CIE XYZ, Yxy, L*a*b*, Hunter LAB, L*C*h°, CMC (l:c), CIE94, DIN6172, Whiteness (CIE, Ganz, ASTM E313), Yellowness (ASTM D1925, E313), Delta E (ΔE*ab, ΔE00, ΔE94) |
| Repeatability | ≤0.08 ΔE*ab (white tile, 10 readings) |
| Lamp Type | Tungsten-halogen (long-life, stable output) |
| Aperture Options | 8 mm, 12 mm, 20 mm (user-selectable) |
| Display | High-contrast LCD with intuitive icon-based interface |
| Connectivity | USB port for data export and firmware updates |
| Compliance | ISO 5-4:2022, ISO 7724-1:2022, ASTM D2244, ASTM E308, CIE No. 15:2018 |
| Software Compatibility | OnColor™ v5.x (Windows-based, supports GLP audit trail, user access levels, report generation per ISO/IEC 17025) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | RT850I |
| Instrument Type | Integrating Sphere Spectrophotometer |
| Measurement Geometry | d/8° (diffuse illumination / 8° viewing angle), compliant with CIE No. 15, ISO 7724-1, ASTM E308, and DIN 5033-7 |
| Illuminants | D65, A, C, F2, F7, F11 |
| Observer Angle | 10° standard observer |
| Wavelength Range | 400–700 nm |
| Optical Resolution | 10 nm |
| Repeatability | ΔE*ab < 0.02 (white tile, 10 readings) |
| Inter-instrument Agreement | ΔE*ab < 0.15 (BCRA Series II tiles) |
| Sample Port Diameter | 25 mm (standard), optional 8 mm & 4 mm apertures |
| Data Output | CIE L*a*b*, L*C*h*, ΔE*ab, ΔE*cmc, ΔE*94, ΔE*00, Yxy, XYZ, spectral reflectance curves |
| Compliance | CE, UKCA, RoHS |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Model | RT850i |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Sample Port Options | 3 selectable apertures |
| UV Filter | Optional |
| Preview Imaging System | Built-in real-time sample positioning camera |
| Connectivity | USB 2.0 |
| Software | OnColor™ PC software suite |
| Compliance | Designed for ISO 7724, ASTM E308, CIE No. 15, DIN 5033, and ISO 11664 colorimetric standards |
| Sample Compatibility | Opaque solids, translucent plastics, liquids (in cuvettes), powders (with accessory holders), textiles, coatings, glass, petroleum products |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268 |
| Type | Automatic Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Areas (mm) | 20°: 10×10, 60°: 9×15, 85°: 5×36 |
| Measurement Ranges | 20°: 0–2000 GU, 60°: 0–1000 GU, 85°: 0–160 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–2000 GU) |
| Geometry | CIE 1931 Standard Observer (2°), Illuminant C |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Response Time | 1.0 s |
| Display | 3.5″ TFT capacitive touchscreen |
| Data Storage | 1,000 readings (Basic), 5,000 (Statistical & Continuous modes) |
| Interface | USB, RS-232 |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Software | OnShade QC Suite (GLP-compliant reporting, audit trail, export to CSV/PDF) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268/60 Gloss Meter |
| Measurement Angles | 20° / 60° / 85° (TG268) |
| Compliance | ISO 2813, ASTM D 523, ASTM D 2457, GB/T 9754 |
| Measurement Area | 20°: 10 × 10 mm |
| 60° | 9 × 15 mm |
| 85° | 5 × 3 mm (TG268) |
| 60° | 9 × 15 mm (TG60) |
| Gloss Range | 20°: 0–2000 GU |
| 60° | 0–1000 GU |
| 85° | 0–160 GU (TG268) |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) — TG268 |
| Reproducibility | ±0.2 GU / ±0.5 GU / ±0.5% GU across ranges |
| Measurement Time | 1.0 s (TG268), 0.5 s (TG60) |
| Display | 3.5-inch TFT true-color capacitive touchscreen |
| Data Storage | Basic mode: 1,000 readings |
| Statistical & Continuous modes | 5,000 readings each |
| Interface | USB & RS232 |
| Power | 3200 mAh Li-ion battery (≥10,000 measurements per charge, ~8 h runtime) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Operating Environment | 0–40 °C, <85% RH (non-condensing) |
| Storage | −20–50 °C |
| Standard Accessories | Calibration tiles (gloss standards), OnShade QC software, AC adapter, USB cable, user manual |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TLC120/60 |
| Light Sources | CIE Illuminant A (2856 K), D65 (6500 K), TL84 (4000 K), UV (365 nm), CWF (4150 K), TL83/U30 (3000 K) |
| Dimensions (TLC120) | 1310 × 600 × 800 mm |
| Weight (TLC120) | 65 kg |
| Dimensions (TLC60) | 710 × 530 × 570 mm |
| Weight (TLC60) | 38 kg |
| Compliance | ASTM D1729, ISO 3664:2009, DIN 6173-2, BS 950-1, ANSI IT8.7/2 |