| Brand | Newport |
|---|---|
| Origin | USA |
| Body Material | 316 Stainless Steel |
| Optical Path Length | 1 cm |
| Clear Aperture | 11/16 in (≈17.5 mm) |
| Pressure Rating | 100,000 psi (689 MPa) |
| Port Configuration | Two 1/4-in SUPERPRESSURE fittings, orthogonal (90° apart) |
| Application | In-situ UV-Vis-NIR spectroscopy under extreme pressure conditions |
| Compliance | Designed for integration with ASTM E275, ISO 1042, and USP <857> spectrophotometric validation protocols |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | 4-5800 Series (ASTM E662 / FAA TSO-C135 Compliant) |
| Chamber Volume | 0.50 m³ |
| Optical Path Length | 914 mm |
| Sample Area | 0.0774 m² |
| Radiation Heat Flux | 2.5 W/cm² ±0.25 W/cm² |
| Power Supply | 230 V, 50–60 Hz |
| Dimensions (H×W×D) | 1956 × 1169 × 966 mm |
| Weight | 205 kg |
| Light Source | Tungsten-Halogen Lamp with ND2 Neutral Density Filter (Transmission Accuracy: 0.0001%) |
| Photodetector System | NIST-Traceable Silicon Photodiode Assembly |
| Data Acquisition | Real-time Transmittance vs. Time Plotting at 1 Hz Sampling Rate |
| Compliance | ASTM E662, ASTM F814, FAR 25.853, NFPA 258, BS 6401, FAA AC 20-135, ATS 1000.01, NES 711 |
| Brand | Newport |
|---|---|
| Origin | USA |
| Type | Imported Laboratory Diaphragm Compressor |
| Model Series | 46-14021-2, 46-14025-2, 46-14035-2, 46-14060-2, 46-14067, 46-14068 |
| Compression Principle | Pneumatically Actuated Metal Diaphragm |
| Flow Rate | 0–0.5 Nm³/h |
| Maximum Output Pressure | 0–200 MPa (0–30,000 psi) |
| Dew Point | +3 °C at Atmospheric Pressure |
| Particulate Filtration | <0.01 µm |
| Air Drive Inlet/Outlet Port | 0.053 cm / 1.27 cm |
| Fluid Side Port | 0.635 cm OD Tubing |
| Power Requirement | 50 Hz AC Supply |
| Compliance | Designed for ISO 8573-1 Class 2 compressed gas purity and GLP-compliant lab environments |
| Brand | Newport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NP Series |
| Price | USD $150,000 |
| Max Temperature | 200 °C |
| Number of Channels | 3 |
| Extraction Vessel Volume | 20 L |
| Max Operating Pressure | 68.9 MPa |
| CO₂ Mass Flow Rate | 1 kg/min |
| Extraction Range | Configurable |
| Brand | Newport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PMKIT |
| Core Components | Optical Power Meter, Detectors, Mounting Hardware |
| Compatible Detectors | 818-UV/DB, 818-SL/DB, 818-IR/DB, 818P-010-12 |
| Power Meter | 1916-R Handheld Optical Power Meter |
| Detector Options | Silicon (Si), Germanium (Ge), UV-enhanced Si, Thermopile |
| Wavelength Ranges | 200–1100 nm (UV), 400–1100 nm (Si), 780–1800 nm (Ge), 190–10600 nm (Thermopile) |
| Power Range | 100 pW – 10 W |
| Resolution | 0.01% of Full Scale |
| Accuracy | ±1% (typical, wavelength-dependent) |
| Max. Avg. Power Density | 2 W/cm² |
| Uncertainty (w/ Attenuator) | ≤8% (UV), ≤5% (IR), ≤2.5% (Thermopile) |
| Optional Accessories | Fiber Adapters (sold separately), OD3 Removable Attenuator (integrated with 818-series detectors) |
| Brand | Newport |
|---|---|
| Manufacturer | Richardson Gratings (a Newport Corporation subsidiary) |
| Origin | USA |
| Product Type | Optical Instrument Component |
| Category | Diffraction Grating |
| Model | SPL Series |
| Grating Fabrication | Holographic or Ruled |
| Substrate Material | Fused Silica or BK7 (standard) |
| Coating | Protected Aluminum (standard), optional UV-enhanced, Au, or dielectric coatings |
| Line Density Range | 750–4320 lines/mm |
| Spectral Range | 130 nm – 2.3 µm |
| Maximum Clear Aperture | up to 130 mm × 160 mm |
| Efficiency Optimization | Blazed or High-Modulation Design |
| Compliance | ISO 10110 optical surface specifications, MIL-PRF-13830B scratch-dig standards |
| Brand | Newport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RPR Series |
| Price | USD $1,200–$3,500 (varies by size and configuration) |
| Surface Thickness | 4.8 mm |
| Core Structure | Vertically bonded trussed honeycomb with constrained-layer damping |
| Working Surface | Ferromagnetic 430 stainless steel |
| Mounting Holes | 1/4"-20 or M6 on 1.0" (25 mm) grid |
| Hole Sealing | Conical polymer cups, 19 mm deep |
| Edge Finish | Damped composite edge |
| Compliance | ASTM E1776, ISO 10816-5 (vibration sensitivity reference), compatible with GLP/GMP lab infrastructure |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | RS2000 |
| Surface Thickness | 4.8 mm |
| Core Construction | Vertically bonded trussed honeycomb (0.010 in. steel sheets) with triple-core interface (0.030 in.) |
| Damping System | 2 precision-tuned mass dampers (25–525 Hz range) |
| Top Material | Ferromagnetic 430 stainless steel |
| Mounting Holes | 1/4"-20 or M6, 19 mm deep conical polymer cups |
| Grid Pitch | 1.0 in. (25 mm for M-version) |
| Edge Finish | Composite-damped edge |
| Compliance | ASTM E1774-22 (Optical Table Vibration Performance), ISO 10816-5 (Vibration Severity Assessment for Laboratory Equipment) |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | RS4000 |
| Surface Thickness | 4.8 mm |
| Core Construction | Vertically Bonded Trussed Honeycomb (0.010 in. Steel Sheets) |
| Damping System | 6 Precision-Tuned Mass-Damping Units (25–525 Hz) |
| Mounting Holes | 1/4"-20 or M6, 19 mm Depth, Conical Polymer Cups |
| Grid Pitch | 1.0 in. (25 mm for M-version) |
| Edge Finish | Composite |
| Load Interface | Triple-Core Truss Interface |
| Dimensions | 1200 × 2400 × 305 mm (48 × 96 × 12 in.) |
| Brand | Newport |
|---|---|
| Origin | USA |
| Model | SmartTables HD |
| Platform Surface Thickness | 4.8 mm |
| Material | Ferromagnetic 430 Stainless Steel |
| Mounting Hole Pattern | 1.0 in. (25 mm for M-versions) Grid |
| Mounting Thread | 1/4-20 (M6 for M-versions) |
| Hole Depth | 19 mm |
| Sealed Hole Type | Conical cup, non-corrosive high-impact polymer |
| Active Dampers | 2 × IQ Active Dampers |
| Passive Dampers | 2 × Precision-Tuned Passive Dampers |
| Damping Frequency Range | 80–550 Hz |
| Vibration Monitoring Range | 10–820 Hz |
| Controller | ST-300 (USB interface) |
| Power Supply | 100–240 VAC, 50/60 Hz, 1.5 A |
| Dimensions (L × W × H) | 1200 × 2400 × 203 mm (4 ft × 8 ft × 8 in) |
| Surface Flatness | ±0.004 in. per 2 sq. ft. |
| Structural Core | Vertically bonded constrained-layer honeycomb with proprietary viscoelastic damping material |
| Compatibility | S-2000A isolators, LabLegs, SL/RL series supports |