Nikon
Filter
Showing 31–45 of 45 results
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2 |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including Plan Apochromat Phase), DIC-like Relief Contrast*¹ |
| Fluorescence Capability | Yes (Ts2-FL variant) |
| Illumination | High-Brightness White LED Transmitted Light (with Köhler illumination via built-in fly-eye lens) |
| Eyepiece Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Port Split: 100/0 or 0/100 |
| Focusing Mechanism | Objective Nosepiece Movement (7 mm up / 1.5 mm down), Coarse Focus: 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) |
| Stage | Flat Stage (170 × 247 mm) |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 V AC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (T-PH), Differential Interference Contrast (DIC)-like Relief Contrast, Epifluorescence |
| Illumination | High-Brightness White LED Transmitted Light + Modular LED Epifluorescence (385, 455, 470, 505, 525, 560, 590, 625 nm) |
| Eyepiece Field Number | 22 (10×), 16 (15×), 12.5 (20×) |
| Tube Angle | 45°, Interpupillary Distance: 50–75 mm (Siedentopf), Trinocular Port (100/0 or 0/100 beam splitter) |
| Focus Travel | 8.5 mm total (7 mm upward, 1.5 mm downward) |
| Coarse Focus | 37.7 mm/rev, Fine Focus: 0.2 mm/rev, Adjustable Coarse Focus Torque |
| Objective Turret | 5-Position |
| Condenser | ELWD (NA 0.3, WD 75 mm) with Pre-centered and Centerable Phase Contrast Sliders (for 10×, 20×, 40×) and Relief Contrast Sliders (dual-side configuration required) |
| Stage | Fixed Plate Stage (170 × 247 mm) with Acrylic Circular Cover Slip |
| Compatible with Multiple Sample Holders | CS-HP35 (35 mm dish), CS-HLP100 (100 mm dish), CS-HT (Terasaki plate & Ø65 mm dish), CS-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal holder for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide holder), C-S-HLS (circular cover slip kit) |
| Fluorescence Attachment | Motorized Filter Cube Turret (3 positions + brightfield slot), Integrated Noise-Reduction Mechanism, Optional Light Shield |
| Dimensions (W×D×H) | 236 × 548 × 471 mm (Ts2), 236 × 564 × 471 mm (Ts2-FL) |
| Weight | ~13 kg (Ts2), ~14.5 kg (Ts2-FL) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 0.35 A |
| Power Consumption | 15 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TMC), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Fluorescence Epi-Illumination, Spindle Observation |
| Illumination | High-Brightness White LED Transmitted Light (with Homogenizing Lens), LED Epi-Illumination (up to 4 interchangeable units |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10× (22 mm FOV), 12.5× (16 mm), 15× (14.5 mm) |
| Binocular Tube | Siedentopf-type, interpupillary distance 50–75 mm, tilt angle 35° (standard) or 15–45° (ergonomic) |
| Camera Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-movement |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Objective Turret | 6-position, with DIC prism slots |
| Condenser | Rotating condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Stage Adapters | C-S-HP35 (35 mm dish), C-S-HLP100 (100 mm dish), C-S-HT (Terasaki plates & Ø65 mm dishes), C-S-HS (slide, Ø54 mm dish, hemocytometer), C-S-HU (universal for Terasaki, slides, Ø35–65 mm dishes, hemocytometer), C-S-HG (circular glass slide), C-S-HLS (circular slide kit), TC-S-HA (acrylic stage plate) |
| Fluorescence Accessories | Motorized filter cube turret (body-integrated, noise-reduction design) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A |
| Power Consumption | 30 W |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | ECLIPSE Ts2R-FL |
| Optical System | CFI60 Infinity-Corrected |
| Observation Modes | Brightfield, Phase Contrast (including TIRF-capable phase), DIC, NAMC (Nikon Advanced Modulation Contrast), Relief Contrast, Spindle Observation, Epifluorescence |
| Illumination | High-Intensity White LED Transmitted Light (with Köhler illumination and built-in fly-eye lens) |
| wavelengths | 385, 455, 470, 505, 525, 590, 625 nm) |
| Eyepiece Options | 10×/22, 12.5×/16, 15×/14.5 field number |
| Trinocular Port Split Ratios | 100:0 / 0:100, 100:0 / 20:80, 100:0 / 50:50 |
| Focus Mechanism | Objective nosepiece-driven Z-axis movement (8 mm upward, 3 mm downward travel) |
| coarse focus | 5.0 mm/rev, fine focus: 0.1 mm/rev |
| Nosepiece | 6-position revolver with DIC prism slots |
| Condenser | Multi-position condenser turret (7-slot), compatible with ELWD, LWD, and NAMC condensers |
| Stage | Flat stage (260 × 300 mm) |
| Fluorescence Accessories | Motorized filter cube turret (with noise-reduction mechanism) |
| Dimensions (W×D×H) | 286 × 466 × 542 mm |
| Weight | ~17–18 kg |
| Power Supply | 100–240 V AC, <0.65 A, 30 W max |
| Brand | NIKON |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JCM-7000 |
| Instrument Type | Desktop SEM |
| Electron Gun | Tungsten Filament |
| SEM Class | Entry-Level Tungsten-Filament SEM |
| Secondary Electron Image Resolution | 20 nm |
| Magnification Range | 10×–60,000× |
| Accelerating Voltages | 5 kV, 10 kV, 15 kV |
| Backscattered Electron Image Resolution | 20 nm |
| Vacuum Modes | High Vacuum & Low Vacuum |
| Sample Chamber Capacity | Ø ≥80 mm × H ≥50 mm |
| Motorized Stage Travel | X ≥40 mm, Y ≥40 mm |
| Detector Configuration | Secondary Electron Detector (SED) + Backscattered Electron Detector (BSED) |
| Imaging Modes | SE, BSE (compositional & topographic), Real-Time 3D Reconstruction |
| Dual-Channel Simultaneous Display | Yes |
| Image Storage Resolutions | 1280×960, 2560×1920, 5120×3840 pixels |
| Power Supply | AC 100–240 V, 50/60 Hz, ≤700 VA |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 30–60 % RH (non-condensing) |
| Ground Resistance | <100 Ω |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | LV100N POL |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | 12V/50W Halogen with Köhler Illumination & Homogenizing Fly-Eye Lens |
| Polarization Components | Rotatable Analyzer (0.1° resolution), Focusing Bertrand Lens, Standard λ/4 Retardation Plate & Quartz Wedge, Optional Senarmont Compensator (0–1λ range) |
| Stage | Rotatable Circular Stage (360°, 1° scale, 45° detents), Mechanical Stage (35 × 25 mm travel), Optional High-Profile Stage for Thick Samples |
| Focus Travel | 30 mm with Upper-Limit Safety Stop |
| Compliance | RoHS-compliant lens elements (lead-free arsenic glass) |
| Software Compatibility | NIS-Elements AR/BR (image stitching, quantitative birefringence mapping, automated report generation) |
| Observation Modes | Transmitted Polarized Light, Reflected Polarized Light, Brightfield, Darkfield, DIC, Phase Contrast, Fluorescence, Interference Contrast |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | LV100POL |
| Optical System | CFI60 Infinity-Corrected |
| Illumination | 12 V / 50 W Halogen (Transmitted & Reflected) |
| Condenser | Stress-Free Achromatic, NA 0.9 |
| Stage | Precision 360° Rotatable Circular Stage with 1° Graduation and 45° Audible Click Stops |
| Objective Turret | Centerable Five-Position Nosepiece with DIN Slots |
| Analyzer | 360° Rotatable, 0.1° Graduation |
| Bertrand Lens | Built-in, Focusing and Centering Adjustable |
| Compensators | Standard λ/4 Gypsum and Mica Plates |
| Polarizer | Fixed in Condenser Mount with Angular Scale |
| Eyepieces | 10× CM Widefield (22 mm FOV) with Crosshair and Micrometer Scale |
| Focus Mechanism | Coaxial Coarse/Fine Drive |
| Weight | ~17 kg (Trinocular Configuration) |
| Power Consumption | 75 W (1.2 A) |
| Brand | Nikon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nikon LV100POL |
| Pricing | Upon Request |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIM E |
| Resolution (XY) | ~115 nm |
| Resolution (Z, 3D-SIM) | ~300 nm |
| Imaging Speed | ~1 frame/sec |
| Field of View | 66 µm × 66 µm |
| Objective Compatibility | High-NA objectives up to NA 1.49 |
| Modality | Structured Illumination Microscopy (SIM) with integrated confocal capability |
| 3D Reconstruction Modes | Slice and Stack |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIM E |
| Resolution | ≤85 nm (lateral, TIRF-SIM mode) |
| Temporal Resolution | 0.6 s/frame (2D/TIRF-SIM), ~1 s/frame (3D-SIM) |
| Objective Compatibility | CFI Apo TIRF 100× Oil (NA 1.49) |
| Illumination | Multi-laser SIM (up to 5 lasers, e.g., 405/488/561/640/730 nm) |
| Imaging Modes | TIRF-SIM, 2D-SIM, 3D-SIM |
| Optical Sectioning Thickness | Up to 20 µm |
| Axial Resolution | ~300 nm (3D-SIM) |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with FDA 21 CFR Part 11–ready software platforms |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-SIMS |
| Lateral Resolution (XY, FWHM) | 86 nm (TIRF-SIM), 115 nm (3D-SIM) |
| Axial Resolution (Z, FWHM) | 269 nm (3D-SIM) |
| Max Imaging Speed | 15 fps (TIRF-SIM/2D-SIM, 2 ms exposure) |
| Reconstruction Image Size | 1024 × 1024 or 2048 × 2048 pixels |
| Imaging Modes | TIRF-SIM, 2D-SIM, 3D-SIM (single-frame & time-series reconstruction) |
| Multicolor Capability | Up to 6 channels, simultaneous dual-color acquisition |
| Compatible Laser Units | LU-NV (std: 405/488/561/640 nm |
| opt | 445 nm), LUD-HV (std: same |
| opt | 445/515 nm), Ziva Light Engine (405/446/476/518/545/637 nm) |
| Compatible Microscope Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope with Perfect Focus System (PFS), encoded motorized XY stage, and piezo-driven Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC Oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC Oil (NA 1.49), CFI SR Plan Apochromat IR 60XC WI (NA 1.27), CFI SR Plan Apochromat IR 60XAC WI (NA 1.27), CFI Plan Apochromat Lambda 60XC (NA 0.95), CFI Plan Apochromat Lambda 40XC (NA 0.95) |
| Camera | ORCA-Fusion BT sCMOS (Hamamatsu Photonics K.K.) |
| Software | NIS-Elements AR (with NIS-A 6D and N-SIM analysis modules required), NIS-Elements C (for AX/AX R confocal systems) |
| Operating Environment | 20–28 °C (±1.5 °C) |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | N-STORM |
| XY Resolution | ~20 nm |
| Z Resolution | ~50 nm |
| Imaging Modes | 2D-STORM (n-STORM, c-STORM), 3D-STORM (n-STORM, c-STORM), 3D-Stack |
| Maximum Field of View | 80 µm × 80 µm |
| Frame Rate | up to 500 Hz |
| Multicolor Capability | up to 3 channels |
| Compatible Lasers | LU-NV Series (405/488/561/647 nm), LUD-H Series (405/488/561/640 nm) |
| Compatible Platform | Nikon ECLIPSE Ti2-E motorized inverted microscope |
| Autofocus System | Perfect Focus System (PFS) with encoder-based motorized XY stage and Piezo Z-stage |
| Objective Lenses | CFI SR HP Plan Apochromat Lambda S 100XC Sil (NA 1.35), CFI SR HP Apochromat TIRF 100XC oil (NA 1.49), CFI SR HP Apochromat TIRF 100XAC oil (NA 1.49), CFI HP Plan Apochromat VC 100X oil (NA 1.40) |
| Camera Options | ORCA-Fusion BT sCMOS (Hamamatsu), iXON Ultra DU-897U EMCCD (Andor) |
| Software | NIS-Elements AR / NIS-Elements C (optional), NIS-A 6D and N-STORM Analysis Module (required) |
| Operating Temperature | 20–25 °C (±0.5 °C) |
| Brand | NIKON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Patch-Clamp Electrophysiology System |
| Pricing | Available Upon Request |
| Brand | Nikon |
|---|---|
| Origin | Japan |
| Model | PF10545MF-UV |
| Spectral Range | 220–900 nm |
| Transmission | >70% across full range |
| Focus Shift Compensation | None required from visible to UV |
| Magnification Range | ∞ to 0.5× |
| Image Distortion | <0.1% across entire magnification range |
| Mount Type | Nikon F-mount (mechanical coupling compatible with manual-focus and AF-compatible bodies via adapter) |
| Brand | Nikon |
|---|---|
| Origin | Germany |
| Model | TS2 |
| Microscope Type | Inverted Microscope |
| Eyepiece Configuration | Trinocular |
| Optical System | CFI60 Infinity-Corrected |
| Focusing Mechanism | Coaxial Coarse/Fine Adjustment |
| Working Distance | Up to 75 mm (with LWD condenser) |
| Condenser Options | Long Working Distance (NA 0.3, WD 75 mm) and Hoffman Modulation Contrast (NA 0.4, WD 44 mm) |
| Fluorescence Capability | Optional Epi-Fluorescence Attachment (up to two filter cubes, 50 W mercury lamp) |
| Camera Port | Standard C-mount compatible port for Nikon digital cameras and third-party imaging systems |
| Ergonomic Design | 45° inclined trinocular head, 400 mm eye-point height, adjustable interpupillary distance (50–75 mm) |
| Stage Height | 195 mm above bench surface |
| Stage Clearance | 190 mm between stage and condenser |
| Phase Contrast | Equipped with Nikon ADL (Apodized Diffraction-Limited) Phase Contrast Objectives |
| Compliance | Designed for GLP-compliant documentation workflows |