PerkinElmer
Filter
Showing 151–175 of 175 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TG-GC/MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Manufacturer Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | TG-hiden MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-IR |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PerkinElmer TG-IR-GC/MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Titan MPS |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 16 × 75 mL vessels or 8 × 100 mL vessels |
| Max Temperature | 260 °C |
| Max Pressure | 100 bar |
| Pressure & Temperature Monitoring | Direct Optical Pressure Control™ (DPC) and Direct Optical Temperature Control™ (DTC) per vessel |
| Vessel Material | TFM™ fluoropolymer |
| Cavity Lining | PFA-coated cylindrical stainless steel |
| Gas Management | Integrated acid-resistant fume capture and continuous cavity venting |
| Software Platform | Linux-based embedded GUI with network-enabled remote access (no client software required) |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Torion T-9 |
| Instrument Type | Portable GC-MS |
| Application Field | Environmental Monitoring |
| Weight | 14.5 kg |
| GC Technology | Low Thermal Mass (LTM) Capillary Column |
| MS Technology | Miniature Toroidal Ion Trap |
| Mass Range | 45–500 amu |
| Resolution | Unit resolution or better |
| Operating Temperature | 175 °C (ion trap) |
| Power Source | Rechargeable Li-ion battery (2.5 h runtime) |
| Carrier Gas | Integrated high-pressure helium cylinder |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Ramp Rate | Up to 2.5 °C/s |
| Column Heating/Cooling | Rapid thermal cycling enabled by resistive LTM heating |
| Vacuum Requirement | ~10⁻³ Torr |
| Display | Color touchscreen interface |
| Software | CHROMION with NIST library integration, deconvolution, spectral averaging, and quantitative methods (internal/external standard) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TrasION 1080 ICP-MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 100 |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cryo-Focusing Trap Temperature Range | Down to −30 °C |
| Analyte Recovery Rate | >80% |
| Sample Capacity | 20 Sample Tubes |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 16 |
| Sample Capacity | 16 positions |
| Oven Temperature Range | 35–210 °C (1 °C increments) |
| Maximum Vial Heating Temperature | 210 °C |
| Minimum Ambient Operating Temperature | 15 °C |
| Maximum Ambient Operating Temperature | 32 °C |
| Dimensions (W × H × D) | 43.0 × 61.0 × 50.8 cm |
| Weight | 32.0 kg |
| Calibration & Performance | RSD ≤1.5% for 0.4% aqueous ethanol |
| Injection Modes | Pressure-balanced static headspace, trap-enriched headspace, multiple headspace extraction (MHE), and auto-overlap heating (up to 12 vials) |
| Gas Control Options | Manual pressure control (0–60 psig) or electronic pneumatic control (PPC) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TurboMatrix 40 |
| Product Category | Chromatography |
| Usage Duration | 5–7 Years |
| Warranty | 6 Months |
| Power Supply | 100/120/240 V, 50/60 Hz, 900 VA |
| Dimensions (W×D×H) | 43 × 61 × 61 cm |
| Weight | 33 kg |
| Operating Environment | 15–32 °C, ≤75% RH (non-condensing) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 40 |
| Sample Capacity | 40 positions |
| Vial Size | 10 mL |
| Injection Valve Quantitative Loop Volume | 1 mL |
| Headspace Vial Heating Range | 35–210 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 210 °C |
| Sampling Technique | Pressure-Balanced Static/Dynamic Headspace with Optional Trap Enrichment |
| Automation Level | Fully Automated |
| Compatibility | Universal GC interface (all major GC brands) |
| Regulatory Compliance Support | 21 CFR Part 11-ready software architecture (when paired with TurboMass or Chromera CDS) |
| Data Integrity Features | Audit trail, user access levels, electronic signatures (software-dependent) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Product Type | Automated Thermal Desorber (Two-Stage) |
| Sample Capacity | 50-tube carousel |
| Cold Trap Temperature Range | −30 °C (electronic cooling, no liquid cryogen required) |
| Desorption Temperature Range | Ambient to 400 °C |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Compliance | Compatible with all major GC systems (Agilent, Thermo Fisher, Shimadzu, etc.) |
| Software Interface | Graphical touchscreen with multilingual support (including English, Chinese, Spanish, German) |
| Data Integrity Features | Audit trail-ready configuration for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 650 ATD |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Cryogen-Free Cooling | Yes |
| GC Compatibility | Universal (all major GC brands) |
| Interface | Standard GC inlet connection (e.g., split/splitless, PTV) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PE 650 ATD |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C (electronic cooling, no liquid cryogen) |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 sample tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| GC Compatibility | Universal interface for all major GC systems |
| Software Interface | Touchscreen GUI with graphical workflow navigation |
| Brand | PerkinElmer |
|---|---|
| Model | TurboMatrix ATD |
| Origin | Canada |
| Instrument Type | Thermal Desorption Unit for Gas Chromatography |
| Configuration | Single-tube and 50-tube autosampler options |
| Cooling Technology | Peltier-cooled two-stage desorption |
| Sample Introduction Modes | Online ambient air, continuous gas stream, or canister sampling |
| Integrated Components | Mass flow controller, Nafion™-based moisture removal, purified air drying system, automated flow selector for sample/calibrant switching |
| Operational Age | 3–4 years |
| Refurbishment Status | Fully tested and certified by SpectraLab Scientific |
| Warranty | 6 months limited warranty |
| Compliance | Designed to support EPA TO-17, ASTM D6196, ISO 16017-1, and USP <467> residual solvent analysis workflows |
| Software Compatibility | Fully interoperable with PerkinElmer TurboMass GC/MS and Chromera CDS platforms |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TurboMatrix HS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Sample Vial Heating Range | 35–210 °C (1 °C increments) |
| Pressure Control Options | Manual (0–60 psig) or Electronic Pneumatic Control (EPC/PPC) |
| Detection Limit Enhancement | Integrated Focused Cryo-Trap for analyte enrichment |
| Typical Application Performance | ≤1.5% RSD for 0.4% aqueous ethanol |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Configuration | 40-sample carousel |
| Automation | Fully automated thermal equilibration, pressurization, sampling, and injection sequence |
| Interface | Universal GC/GC-MS compatible (standard 1/16" OD stainless steel transfer line with Swagelok fittings) |
| User Interface | Color LCD touchscreen with graphical workflow navigation |
| Safety Mechanism | Patented pressure-relief venting system integrated into sample vials |
| Optional Accessories | High-pressure sampling kit, backflush module, cryo-trap concentrator, orbital shaker module, zero-dead-volume (ZDV) liner for capillary inlet |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 35–210 °C |
| Valve Temperature Control Range | 35–210 °C |
| Loop Volume | 1 mL |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Sampling Technique | Pressure-Balanced Headspace Injection |
| Compatible GC Interfaces | Universal (via standard GC inlet septumless or split/splitless ports) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PerkinElmer DSC 8500 coupled with EXFO® UV Curing System |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Zero and Ultra Zero |
| Hydrocarbon Removal Principle | Catalytic Oxidation (FID-compatible) |
| Output Flow Rate | 1.5–30.0 L/min (model-dependent) |
| Maximum Continuous Flow | 1.5 L/min (Zero series), up to 30.0 L/min (Ultra Zero series) |
| Hydrocarbon Content | < 0.1 ppm (C1–C6, as methane equivalent) |
| Dew Point | ≤ –70 °C (Ultra Zero, 1.5 L/min model) |
| CO Concentration | < 5 ppm (Ultra Zero, 1.5 L/min) |
| NOₓ Concentration | < 0.1 ppm (Ultra Zero, 1.5 L/min) |
| Power Requirement | 115/230 VAC, 250–500 W (model-dependent) |