| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPR Series |
| Max. Temperature | 350 °C |
| Max. Pressure | 68.9 MPa (10,000 psi) |
| Reaction Volume | 50 mL to 8 L |
| Stirring | Magnetic Drive Dual-Impeller |
| Safety | ASME-Compliant Vessel with Rupture Disc |
| Control Interface | Color Touchscreen with Closed-Loop PID Temperature & Speed Control |
| Data Output | RS-232 Serial Port |
| Optional Accessories | Sight Glass, Feed/Withdrawal Ports, Cooling Coil, Sample Loop, Reagent Addition Module |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 |
| Typical Applications | Catalytic Synthesis, Hydrogenation, Oxidation, Polymerization, Supercritical Fluid Extraction (SFE), Isomerization, Dehydrogenation |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPR Series Laboratory-Scale System |
| Price | USD $100,000 |
| Max Operating Temperature | 200 °C |
| Pressure Rating | 10,000 PSI (68.9 MPa) |
| Extraction Volumes | 50 mL – 8 L |
| Flow Control | Programmable via integrated high-pressure pump and back-pressure regulator |
| Channel Configuration | Single- or multi-channel (configurable) |
| Application Scope | Supercritical fluid dyeing, reaction, extraction, drying, and cleaning |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPR |
| Price | USD $200,000 |
| Max Temperature | 350 °C |
| Channel Configuration | 1–4 Independent Channels |
| Extraction/Reaction Volume | 50 mL to 8 L |
| Max Pressure | 10,000 psi (68.9 MPa) |
| Max Flow Rate | 25 mL/min |
| Sample Compatibility | Plant matrices, pharmaceuticals, natural products, polymers, catalysts |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-10 / SFT-20 / SFT-Nex10 |
| Flow Rate | 0.00–250.00 mL/min |
| Max Pressure | 70 MPa (10,000 psi) |
| Pressure Accuracy | ±2% of full scale |
| Flow Accuracy | ±2% (methanol), ±5% (CO₂, liquid-equivalent) |
| Flow Precision | 0.5% RSD (methanol) |
| Dimensions (SFT-20) | 25 × 46 × 56 cm |
| Weight (SFT-20) | 27 kg |
| Power | 220–240 VAC, 50–60 Hz |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | PM-II with Phase Detection Capability |
| Max Temperature | 150 °C |
| Max Pressure | 10,000 psi (680 bar) |
| Extraction Vessel Volume | 30 mL |
| Flow Rate Range | 0–24.00 mL/min |
| Solvent Delivery | CO₂ + Co-solvent (e.g., methanol) |
| Vessel Construction | 316 Stainless Steel with 3/8″ Quartz Window |
| Pressure Accuracy | ±2 psi |
| Temperature Accuracy | ±0.5 °C |
| Video Monitoring | Color CCD Camera with NTSC Output |
| Power | 220 VAC, Single Phase |
| Dimensions (W×D×H) | 450×450×200 mm |
| Weight | 18.2 kg |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | PM-II |
| Maximum Temperature | 150 °C |
| Number of Channels | 1 |
| Extraction Volume | 3–30 mL |
| Maximum Pressure | 10,000 psi (69 MPa) |
| Maximum Flow Rate | 0–24 mL/min |
| Extraction Capacity | 3–30 mL/h |
| Pressure Accuracy | ±2 psi |
| Temperature Accuracy | ±0.5 °C |
| Sample Cell Material | 316 Stainless Steel |
| View Window | 3/8″ Fused Quartz |
| Burst Disc Rating | 11,500 psi (79 MPa) |
| Compression Ratio | 10:1 |
| Heating Power | 500 W |
| Control | Fuzzy Logic Temperature Controller with RTD Feedback |
| Imaging System | 1/3″ Color CCD Camera with Variable-Focus Lens, Fiber-Optic Illumination, NTSC-Compatible Monitor & VCR Recording |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Range | Lab-Scale to Pilot-Industrial |
| Price Range | USD $28,000 – $72,000 (FOB) |
| Max Temperature | 500 °C |
| Number of Channels | Single |
| Extraction/Reaction Volume | 100–1000 mL |
| Max Operating Pressure | 10,000 psi (68.9 MPa) |
| Max Water Flow Rate | Up to 100 mL/min |
| Max H₂O₂ Flow Rate | Up to 24 mL/min @ 6000 psi |
| Oxidant Delivery | Liquid H₂O₂ and/or Compressed O₂/Gas Mixtures |
| Reactor Material | Inconel 625 (SCWO-1000), Hastelloy C-276 (SCWO-250), SS316L (SCWO-100) |
| Compliance | ASTM D7575, ISO 11923, USP <621>, FDA 21 CFR Part 11-ready data logging |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SCWR Series |
| Vessel Volume | 100 mL – 8,000 mL |
| Operating Pressure | 31–35 MPa (4,500–5,000 PSI) |
| Max. Operating Temperature | 500–600 °C |
| Construction Material | Inconel 625 |
| Pump Type | Reciprocating Dual-Piston High-Pressure Water Pump |
| Temperature Control | Fully Automated PID Controller |
| Pressure Regulation | Manual Back-Pressure Valve |
| Structural Design | Compact, Mobile Floor-Standing Frame |
| Optional Components | Preheater (≤500 °C, ≤35 MPa), Post-Cooler, Air/O₂ Compressor, Air/O₂ Mass Flow Controller, H₂O₂ Dosing Pump, In-Line pH Sensor, Gas-Liquid Separator, On-Line Desalination Module, PLC/HMI Touchscreen Interface, SCADA Data Acquisition System |
| Compliance | ASME Section VIII Div. 1 (Optional Certification) |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-1000 |
| Max Temperature | 200 °C |
| Max Pressure | 10,000 psi |
| Extraction Vessel Capacity | Up to 4 L (benchtop) or 20 L (cabinet configuration) |
| CO₂ Flow Rate | 1–250 g/min (2–500 mL/min at STP) |
| Temperature Control Accuracy | ±1 °C (in supercritical phase) |
| Throttle Valve Heating | Up to 250 °C |
| Power Requirement | 4000 W heating capacity |
| Dimensions | 92 cm × 61 cm × 76 cm |
| Weight | 100 kg |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SFT-110 Series |
| Max Temperature | 200 °C (optional up to 300 °C) |
| Number of Extraction Vessels | 0–4 |
| Extraction Vessel Volumes | 10, 25, 50, 100 mL |
| Maximum Operating Pressure | 10,000 psi |
| CO₂ Flow Rate | 0–25 mL/min |
| Gas Flow Measurement Range | 0–9.5 SLPM |
| Heating/Cooling | Peltier-based temperature control for preheater and back-pressure regulation |
| Pump Type | Dual-plunger electric CO₂ pump with sapphire pistons, Furon® seals, aluminum pump head, and integrated pressure feedback loop |
| Back-Pressure Regulation | Heated, adjustable micro-circulation metering valve per vessel |
| Collection Options | Solid-phase extraction cartridges, solvent soak traps, or direct condensation |
| Co-solvent Delivery | Optional coaxial or modular co-solvent injection system |
| Compliance | Designed for GLP-compliant operation |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SFT-110 |
| Price | USD $300,000 |
| Max Temperature | 300 °C |
| Number of Channels | 1 |
| Extraction Vessel Volume Options | 10, 25, 50, 100 mL |
| Maximum Operating Pressure | 68.9 MPa (10,000 psi) |
| CO₂ Flow Rate | Up to 25 mL/min |
| Extract Collection Modes | Solid-phase extraction cartridge, solvent soak/liquid trap, or direct collection |
| Cooling System | Peltier-based electronic chiller |
| Flow Meter Range | 0–9.5 SLPM (for CO₂ gas phase) |
| Pump Type | Dual-plunger electric-driven CO₂ pump with sapphire pistons, Furon seals, and aluminum pump head |
| Back Pressure Regulator | Heated, adjustable micro-circulation metering valve |
| Preheater | Fully integrated and factory-calibrated |
| Compliance | Designed for ASTM D7560, ISO 14721, and USP <467> residual solvents methodology support |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFT-110XW Series |
| Price | USD $300,000 |
| Max Temperature | 200 °C |
| Channel Count | Customizable |
| Extraction Vessel Volume | 10–1000 mL |
| Max Operating Pressure | 10,000 psi |
| CO₂ Flow Rate | Up to 25 mL/min |
| Extraction Scope | Botanical matrices (e.g., herbs, seeds, leaves), natural products, and solid organic samples |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model Series | XW |
| Max Temperature | 200 °C |
| Pressure Rating | 10,000 psi |
| Flow Rate Range | 0.01–25.00 mL/min (liquid CO₂, ±2% accuracy) |
| Extractor Volume Options | 10–1000 mL |
| Channel Configuration | 1–4 parallel or serial extraction vessels |
| Back-Pressure Regulator Heating | up to 150 °C |
| Cooling Capacity | 150 W at −10 °C |
| Dimensions (L×W×H) | 29 × 57 × 102 cm |
| Weight (with 100 mL vessel) | 28 kg |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-120XW |
| Maximum Temperature | 200 °C |
| Number of Extraction Vessels | 1–5 |
| Extraction Volume Range | 10–1000 mL |
| Maximum Operating Pressure | 10,000 psi |
| CO₂ Flow Rate | up to 25 mL/min |
| Compliance | Designed for ASTM D7674, ISO 18392, and USP <467> residual solvent analysis workflows |
| Software | SFT-Control v5.2 with 21 CFR Part 11-compliant audit trail |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SFT-130A |
| Max Temperature | 200 °C |
| Extraction Volumes | 100 mL, 250 mL, 500 mL, 1000 mL |
| Max Pressure | 10,000 psi (689 bar / 68.9 MPa) |
| Max CO₂ Flow Rate | 500 mL/min |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-150 |
| Max. Operating Temperature | 350 °C |
| Max. Operating Pressure | 10,000 psi (68.9 MPa) |
| Extractor Volume Range | 50–4000 mL |
| Flow Rate | 1–330 mL/min (1–310 g/min) |
| Channel Configuration | Multi-channel optional |
| Solvent Compatibility | CO₂ (primary), with co-solvent injection capability |
| Heating Power | 2 kW per vessel |
| Temperature Accuracy | ±1 °C |
| Pressure Display Resolution | ±1 psi |
| Safety | Rupture disc for liquid CO₂ overpressure protection |
| Dimensions (L×W×H) | 92 × 61 × 76 cm |
| Net Weight (excl. vessels) | 60 kg |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-250 |
| Max Operating Pressure | 10,000 PSI (68.9 MPa) |
| Max Temperature | 200 °C |
| Extraction Vessel Capacity | Up to 4 L |
| Flow Rate Range | 1–330 mL/min (1–310 g/min) |
| CO₂ & Co-solvent Flow Capability | Enhanced |
| Control Architecture | 4-channel analog PID loop control |
| Heating Power | 4 kW total |
| Safety | Rupture disc for liquid CO₂ overpressure protection |
| Heating Method | Band heaters on all vessels |
| Restriction Valve Heating | Up to 250 °C |
| External Heated Collection Tube | Stainless steel |
| Dimensions (L×W×H) | 92 × 61 × 76 cm |
| Weight (excl. vessels) | 64 kg |
| Electrical Requirement | Universal input |
| Drive Air Supply | ~80 psi (regulated, flow-dependent) |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SFT-PM-II |
| Maximum Temperature | 250 °C (300 °C optional) |
| Number of Extraction Vessels | 1–5 |
| Adjustable Extraction Volume | 3–30 mL |
| Maximum Operating Pressure | 68.9 MPa (10,000 psi) |
| Maximum Liquid CO₂ Flow Rate | 25.0 mL/min |
| Sample Capacity | 1–10 g |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Equipment |
| Model | Supercritical CO₂ Dyeing System |
| Price | USD $300,000 |
| Max Operating Temperature | 150 °C |
| Channel Configuration | Customizable |
| Extraction Vessel Volume Range | 5 mL – 8000 mL |
| Maximum Pressure | 10,000 psi |
| CO₂ Flow Control Range | 0–2500 RPM (via integrated magnetic drive agitator) |
| Applicable Matrices | Botanical extracts, natural dyes, pharmaceutical actives, functional textiles |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT |
| Max. Temperature | 250 °C |
| Max. Pressure | 68.9 MPa |
| Extraction Volume Range | 5–1000 mL |
| Flow Control Resolution | 0.01 mL/min |
| Pressure Control Accuracy | ±1–2 psi |
| Pump Speed Range | 0–2500 rpm |
| CO₂ Pump Type | Electric Dual-Plunger |
| Cooling Method | Solid-State Electronic Refrigeration |
| Preheating | Integrated Fluid Preheat Ring |
| Vessel Options | 5, 10, 25, 50, 100, 200, 300, 500, 1000 mL (total system capacity ≤1000 mL) |
| Compliance | Designed for ASTM D7567, ISO 14852, USP <1225>, and GLP/GMP-aligned operation |