| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | Up to 16,800 positions (via microplate stacking) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | –10°C to 85°C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Detector Options | SPD-40/SPD-40V UV-Vis, SPD-M40 Diode Array Detector (DAD) |
| Compliance | ASTM D7097, ISO 17025, USP <621>, FDA 21 CFR Part 11 (with LabSolutions™ CS audit trail enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | LC-40 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | 162 positions (1.5 mL vials) |
| Injection Volume Range | 0.1–50 µL |
| Column Oven Temperature Range | (Ambient −10 °C) to 100 °C |
| UV-Vis Detection Wavelength Range | 190–1000 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | Nexera LC-40 |
| Application Scope | General-purpose analytical laboratory use |
| Flow Rate Range | Up to 5.0 mL/min |
| Maximum Operating Pressure | 130 MPa (1300 bar) |
| Flow Accuracy | ≤0.1% RSD |
| Injection Volume Range | 0.1–100 µL |
| Sample Tray Capacity | Up to 216 positions (with optional 2nd tray) |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexera LC-40D |
| Instrument Type | Liquid Chromatograph |
| Year of Manufacture / Service Duration | <1 year |
| Warranty | 12 months |
| Compliance | Imported instrument, CE-marked configuration (per standard Shimadzu factory specifications) |
| Software Platform | LabSolutions LC-40 Series (v5.9 or later, validated for GLP/GMP environments) |
| Detection | UV-Vis detector (SPD-M40), dual-wavelength simultaneous monitoring, 190–800 nm range |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-40X3B |
| Category | Liquid Chromatograph (HPLC/UHPLC) |
| Configuration | LC Front-End for LC-MS Coupling |
| Warranty | 12 months |
| Compliance | Designed for ISO/IEC 17025, GLP, and FDA 21 CFR Part 11–ready workflows |
| Software Platform | LabSolutions LCMS v5.1 or later |
| Power Consumption (Standby) | ≤68% reduction vs. prior generation |
| Auto-sampler Injection Speed | ≤5 sec per injection |
| Carryover | <0.001% (typical, validated with caffeine/benzodiazepine test mixtures) |
| Sample Capacity | Up to 44 × 96-well MTP plates via optional Plate Changer |
| Dual-Independent Flow Path Support | Yes (via SIL-40CX dual-inlet configuration) |
| Temperature Control | Active airflow management in sample compartment (±0.5 °C stability, condensation-suppressed) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LC/SFC Switching System |
| Instrument Type | Analytical |
| Detector Compatibility | UV, Photodiode Array (PDA), Mass Spectrometry (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.4–5.0000 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexera UC |
| Instrument Type | Analytical |
| Detector Types | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.0001–5.0000 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexera UC Prep |
| Instrument Type | Semi-Preparative |
| Flow Rate Range | Up to 150.0 mL/min |
| Detector Options | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexera UC |
| Instrument Type | Analytical |
| Detector Options | UV, Photodiode Array (PDA), Mass Spectrometer (MS) |
| Maximum Operating Pressure | 66 MPa |
| Flow Rate Range | 0.0001–5.0000 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexera X2 |
| Configuration | LC-30AD pump, SPD-M30A DAD, SIL-30AC autosampler, CTO-30A column oven, DGU-20A5R degasser, CBM-20A system controller |
| Operating Age | 4 years |
| Pressure Rating | 130 MPa |
| Warranty | 6 months |
| Software Included | LabSolutions LCMS v5.9x or later |
| Compliance | ASTM D7868, ISO 17025-aligned operation, FDA 21 CFR Part 11-ready (audit trail & user authentication enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nexera XS inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Bioanalytical LC |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 105 MPa |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Autosampler Capacity | 252 positions (1 mL vials) / 162 positions (1.5–2 mL vials) / 84 positions (4 mL vials) |
| Column Oven Temperature Range | Ambient −10 °C to 100 °C (85 °C for high-stability operation) |
| UV-Vis Wavelength Range | SPD-40 detector: 190–700 nm |
| SPD-40V detector | 190–1000 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera-e |
| Instrument Type | Comprehensive 2D-LC System |
| Flow Rate Range | Not Applicable (Modular Dual-Flow Architecture) |
| Maximum System Pressure | 130 MPa (2nd Dimension) |
| Sample Injection Positions | Dual Sample Loops with Alternating Switching |
| Injection Volume Range | Configurable via Loop Selection (e.g., 1–100 µL) |
| Column Oven Temperature Range | Ambient to 85 °C |
| Wavelength Range (DAD) | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz (SPD-M30A), 20,000 u/sec (LCMS-IT-TOF) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CAGC-2030 |
| Price Range | USD 42,000 – 70,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexis GC-2030 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cool-down Time | ≤3.4 min (from 450 °C to 50 °C at ambient 22 °C) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexis SCD-2030 |
| Instrument Category | Sulfur-Specific Chromatographic Detector |
| Flow Path Design | Horizontal Combustion Chamber with Ultra-Short Reaction Pathway |
| Maintenance Interval | Ceramic Reactor Tube Replacement in ≤5 Minutes |
| Automation Level | Fully Automated Startup, Vacuum Initiation, Gas Flow Optimization, Baseline Stabilization, Analysis Execution, and Shutdown Sequence |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexlock |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NOA-7000 / CGT-7000 / SOA-7000 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±0.5% of Full Scale |
| Weight | ~14.5–15 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Fixed-Mount Analyzer |
| Model | NSA-3080A |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical (EC) + Paramagnetic (O₂) |
| Gas Components | SO₂, NOₓ, CO, CO₂, O₂ (up to 5 simultaneously) |
| Detection Ranges | NOₓ (100–2500 ppm), SO₂ (100–5000 ppm), CO (100 ppm–1 vol%), CO₂ (5–20 vol%), O₂ (0–25 vol%) |
| Calibration | Automated hourly or weekly zero/span correction |
| Operating Ambient Temperature | −5 to 40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ~700 VA |
| Data Storage | Removable SD card interface |
| Compliance | Designed for continuous emissions monitoring (CEMS) per Chinese HJ 75/76 standards |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Core Analyzers | NSA-3080A Online Gas Analyzer, RBV-DUST/II In-Situ Dust Monitor, VPT511BF-A Volumetric Flow Meter |
| Data Acquisition | Integrated DAQ & Reporting Platform |
| Regulatory Alignment | Designed for compliance with HJ 75–2017, HJ 76–2017, EPA Method 1–4, 6C, 7E, 10, and ISO 12141, ISO 15712 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Off-Flavor Analyzer |
| Instrument Type | Triple Quadrupole Mass Spectrometer (GC-MS/MS) |
| Mass Range | 2–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >20,000:1 (S/N, using chlorobenzene, m/z 112) |
| Scan Speed | 20,000 u/s |
| Chromatographic Configuration | Multi-column switching platform (three polarities: DB-5ms, DB-WAX, InertCap Pure-WAX) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-V CSH |
| Type | Online High-Sensitivity TOC Analyzer |
| Measurement Principle | High-Temperature Catalytic Combustion (680 °C) + Non-Dispersive Infrared (NDIR) Detection |
| TC/IC/TOC Quantification Range | 0–30,000 µg/L C (auto-ranging) |
| Detection Limit | ≤ 2 µg/L C (as TOC) |
| Sample Throughput | Up to 8 channels (with OCT-1 autosampler) |
| Operating Temperature | 10–40 °C |
| Compliance | JIS K 0102, ISO 8245, ASTM D7573, USP <643>, EP 2.2.44 |
| Warranty | 6 months limited hardware warranty |
| Service History | Fully refurbished and performance-verified per Shimadzu OEM calibration protocols |
| Instrument Age | 4 years (manufactured 2020–2021) |
| Condition | Certified operational, cosmetic grade A− (minor surface wear), full functional validation report included |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | PC-55N |
| Compatible Controller | CBM-20A |
| Category | LC System Peripheral Board |
| Warranty | None |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PDA-5000 |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Number of Channels | 24 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Floor-standing |
| Excitation Method | Arc/Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Optical System | Czerny-Turner with Fixed Grating |
| Focal Length | 500 mm (typical for PDA-series) |
| Groove Density | 1200–2400 lines/mm (model-dependent) |
| Wavelength Range | 130–800 nm (vacuum UV to near-IR) |
| Number of Channels | Up to 60 pre-aligned PMT channels |
| Operating Environment | 10–30 °C, <80% RH non-condensing |
| Vacuum System | Continuous rotary vane pump with pressure stabilization |
| Spark Stand | Horizontal sliding enclosed design with stainless steel sample stage |
| Temperature Control | Thermostatically stabilized optical chamber at 38 ± 0.1 °C |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Floor-standing |
| Excitation Source | Arc/Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Optical Configuration | Paschen-Runge Mount |
| Focal Length | 750 mm (typical for PDA-series) |
| Grating Groove Density | 1200–2400 lines/mm (model-dependent) |
| Wavelength Range | 130–800 nm |
| Number of Fixed Channels | Up to 60 analytical channels |
| Nitrogen Detection Limit | ≤5 ppm in steel matrix |
| Compliance | ASTM E415, ISO 11577, JIS G 1253 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PDA-8000 |
| Configuration | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Peakintelligence |
| Chromatography Type | Conventional Gas Chromatography–Mass Spectrometry (GC-MS) |
| Pricing | Available Upon Request |