Shimadzu
Filter
Showing 301–330 of 372 results
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | SIL-30ACMP |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Smart Aroma Database |
| Chromatography Type | Conventional Gas Chromatography–Mass Spectrometry (GC-MS) |
| Compatible Platforms | GCMS-NX series, GCMS-QP2020, GCMS-TQ series, GCMS-QP2010 SE |
| Software Requirement | GCMSsolution Ver. 4.53 SP1 or later |
| Excel Compatibility | Microsoft Excel 2019 (32-/64-bit), Excel 2016 (32-bit) |
| Column Requirement | Shimadzu-recommended capillary columns with validated retention time and retention index protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Smart Metabolites Database Ver.2 |
| Chromatography Type | Conventional GC-MS |
| Database Compound Count | 600+ metabolites |
| Coverage Expansion | Plant secondary metabolites (e.g., catechin, chlorogenic acid), amino acids, fatty acids, sugars |
| Includes | Pre-optimized MRM methods, AART retention time calibration, sample-type-based filtering, derivatization protocols for sugars, GC/MS workflow support, metabolomics handbook |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SMV-300/300RT |
| Mooney Viscosity Range | 0–200 M (extendable to 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotor Speed (SMV-300RT only) | 0.5–5 rpm |
| Rotor Type | L-shaped |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Heating Method | Thin-film heater with optimized PID control |
| Compression Method | Pneumatic cylinder actuation |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points programmable) |
| Scorch Point Setting Range | 0–99.9 M (up to 10 points programmable) |
| Data Logging & Statistical Analysis | Built-in |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Model | SMV-301 / SMV-301RT |
| Compliance Standards | JIS K6300, ISO 289, ASTM D1646, BS 1673 |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range (SMV-301RT) | 0.5–5 rpm |
| Mooney Viscosity Range | 0–200 M (optional 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Rotor Type | L-shaped |
| Curing Point Setting Range | 0–99.9 M (up to 10 points) |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | SNTR-8400AT |
| Instrument Category | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 0–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient +5 °C to 60 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 17 L |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Type | Imported |
| Model | SNTR-8600 |
| Instrument Type | Online Dissolution Tester |
| Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 0–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient +5 to 60 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 17 L |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SolidSpec-3700i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) / InGaAs / Cooled PbS |
| Wavelength Range | 165–3300 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | Variable |
| Stray Light | <0.00005% T (at 340 nm, NaNO₂) |
| Sample Compartment Internal Dimensions | 900 W × 700 D × 350 H mm |
| Max Sample Size | 700 W × 560 D × 40 H mm |
| Automation | Motorized wavelength scanning, optional XY automated sample stage |
| Software | LabSolutions UV-Vis |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | SPD-10AVP |
| Wavelength Range | 190–600 nm |
| Noise | ±0.35 × 10⁻⁵ AU |
| Drift | ≤ ±2 × 10⁻⁴ AU/h |
| Dimensions | 260 × 140 × 420 mm (W × H × D) |
| Weight | 13 kg |
| Operating Temperature | 4–35 °C |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SPM-8100FM |
| Instrument Type | Atomic Force Microscope (AFM) |
| Lateral Positioning Noise | 0.1 nm |
| Vertical Positioning Noise | 0.03 nm |
| Sample Diameter × Thickness | Φ24 mm × 8 mm |
| Sample Stage Travel Range | ±5 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPM-9700HT |
| Instrument Type | Atomic Force Microscope (AFM) |
| XY Positioning Noise | 0.1–0.2 nm (horizontal) |
| Z Positioning Noise | 0.03–0.05 nm (vertical) |
| Sample Size | Ø24 mm × 8 mm |
| Sample Stage Travel Range | ±6 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Atomic Force Microscope (AFM) |
| Category | Materials AFM |
| Position Detection Noise | < 0.02 nm RMS |
| Sample Dimensions | Ø50 mm × 8 mm max thickness |
| XY Stage Travel Range | 5 mm × 5 mm |
| Imaging Resolution | Up to 8192 × 8192 pixels |
| Automation Features | Auto-alignment ("Link On"), Auto-parameter optimization ("NanoAssist"), Fully automated tip exchange and fast 3D mapping |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | SPM-Nanoa |
| Instrument Type | Material-oriented AFM |
| Position Detection Noise | < 0.02 nm (RMS) |
| Sample Diameter | 50 mm |
| Sample Thickness | ≤ 8 mm |
| XY Stage Travel Range | 5 × 5 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | STABLO-AP |
| Application | Static Elimination for Analytical Balances (100–200 g Capacity) |
| Max. Weighing Range | 100 g |
| Readability | 0.01 mg |
| Repeatability | ±0.01 mg |
| Calibration | Automatic |
| Ion Output | Wide-Aperture, Fanless Discharge |
| Discharge Time | ≤10% of Conventional Units |
| Compliance | Designed for ISO/IEC 17025 and GLP Environments |
| Brand | Shimadzu |
|---|---|
| Model | STOV-2030 |
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| External Dimensions | 17.8 L (volume) |
| Compatibility | Nexis GC-2030 Gas Chromatograph |
| Control Interface | GC instrument front panel & LabSolutions software |
| Temperature Control | Independent, programmable, integrated with GC sequence timing |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Type | Imported Instrument |
| Model | TD-30R |
| Instrument Category | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | (Ambient + 15)°C to 430°C |
| Cold Trap Temperature | −40°C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 120 positions |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TMA-60/60H |
| Temperature Range | Ambient to 1000 °C / 1500 °C (optional cryo stage down to −150 °C) |
| Displacement Range | ±5 mm |
| Load Range | ±5 N |
| Sample Dimensions | Ø8 mm × 20 mm (cylindrical) or 5 mm (W) × 1 mm (T) × 20 mm (L) (rectangular) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TNP-4200 |
| Measurement Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate UV Oxidation – UV Absorbance (TN) |
| Detection Range | TN: 0–2 / 5 / 10 / 20 / 50 / 100 / 200 mg N/L |
| TP | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Cycle Time | 60 min (simultaneous TN & TP) |
| Power Consumption | ≤300 VA (AC 100–240 V, 50/60 Hz) |
| Operating Environment | Indoor use only |
| Sample Pretreatment | High-speed rotary homogenizer with auto backwash filter |
| Auto-Cleaning | Scheduled distilled water flush of fluidic pathways |
| Auto-Calibration | Dual-point (zero & span) using standard solutions |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-1000e |
| Price Range | USD 150–1,500 (FOB Japan) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TOC-4200 |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Detection Principle | NDIR (Non-Dispersive Infrared) CO₂ Detection |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (auto-ranging) |
| Cycle Time | Minimum 4 minutes per analysis |
| Carrier Gas | High-Purity Nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, Indoor Installation Only |
| Calibration | Auto-zero & span calibration |
| Sample Handling | Integrated high-speed rotary homogenizer |
| Internal Cleaning | Scheduled distilled-water flush of fluidic pathways |
| Interface | Full-color capacitive touchscreen |
| Communication | MODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O |
| Brand | Shimadzu |
|---|---|
| Model | TOC-4200 |
| Measurement Principle | Catalytic Combustion Oxidation + NDIR CO₂ Detection |
| Oxidation Temperature | 680 °C |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (selectable) |
| Accuracy | ±1.0% of reading |
| Detection Limit | 0.01 ppm |
| Resolution | 0.001 ppb |
| Repeatability | ≤1% RSD |
| Analysis Cycle | Minimum 4 minutes |
| Carrier Gas | High-purity nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, indoor installation only |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TOC-5000A |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-5000A |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Detection Limit | 0.005 ppm C |
| Resolution | 0.001 ppb C |
| Repeatability | ≤3% RSD |
| Sample Types | Liquid (aqueous), Solid (soil, sludge, sediment, wipe samples), Suspended Solids-Rich Water |
| Compliance | Designed for GLP/GMP environments with audit-ready operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-L CPN |
| Detection Range | 4 µg/L to 30,000 µg/L |
| Detection Limit | 4 µg/L |
| Oxidation Method | 680 °C Catalytic Combustion Oxidation |
| Configuration | PC-Controlled with TNM-L Total Nitrogen Module, ASI-L Autosampler, Integrated Tubing & Fittings, Dedicated Control PC with TOC-L Software |
| Warranty | 90 Days |
| Brand | Shimadzu |
|---|---|
| Origin | USA |
| Model | TOC-L CSN |
| Detection Range | 4 µg/L to 30,000 µg/L |
| Detection Limit | 4 µg/L |
| Oxidation Method | 680 °C Catalytic Combustion |
| Sample Types | Aqueous Liquids (with optional SSM-5000A for solids) |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EP 2.2.44 |
| Software | TOC-L Series Control Software (v3.x or later) |
| Warranty | 6 months limited |
| Operational Age | 3–4 years |
| Included Accessories | ASI-L Auto-sampler, OCT-L 8-channel Sampler, TNM-L Total Nitrogen Module, SSM-5000A Solid Sample Module (as configured) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion Oxidation (680 °C) |
| Measurement Range | 4 μg/L to 30,000 mg/L |
| Detection Principle | CO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion |
| Power Savings | Up to 36% vs. prior generation (8 h/day, 5 days/week) |
| Footprint Reduction | Width reduced from ~440 mm to 340 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | TOC-L |
| Price Range | USD 13,500 – 27,000 (FOB Japan) |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion Oxidation |
| Oxidation Temperature | 680 °C |
| Measurement Range | 4 µg/L to 30,000 mg/L as C |
| Detection Method | NDIR (Non-Dispersive Infrared) |
| Sample Types | Liquid aqueous matrices including ultrapure water, wastewater, seawater, and industrial process water |
| Compliance | Designed to meet ASTM D7573, ISO 8245, USP <643>, and EP 2.2.44 requirements |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-V CPH |
| Application Category | Elemental Analysis |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Compliance | JIS K 0102, ISO 8245, ASTM D7573 |
| Measurement Principle | High-Temperature Catalytic Combustion (680 °C) + Non-Dispersive Infrared (NDIR) Detection |
| Sample Throughput | Up to 60 samples/hour (with ASI-V auto-sampler) |
| Detection Range | 4 µg/L – 30,000 mg/L as C |
| Precision | RSD ≤ 3% (at 100 ppb and 10 ppm levels) |
| IC Removal Method | Acidification + Sparging |
| Software Platform | TOC-L Series Control & Data Processing Software (v3.x), compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Shimadzu |
|---|---|
| Origin | USA |
| Model | TOC-V CSN |
| Product Category | Elemental Analysis |
| Instrument Age | 3–5 years |
| Warranty | 6 months |
| Configuration | Includes ASI-V Autosampler, Tubing & Fittings, Dedicated PC with TOC-Control Software |
| Compliance | JIS K 0102, ASTM D7573, ISO 8245, USP <643>, EPA Method 415.3 |
| Measurement Principle | High-Temperature Catalytic Combustion (680 °C) + Non-Dispersive Infrared (NDIR) Detection |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | TOC-V |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±4% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.005 ppm C |
| Repeatability | ≤3% RSD |
| Detection Principle | Catalytic Combustion Oxidation + NDIR Detection |
| Sample Introduction | Programmable 8-Channel Syringe Pump |
| IC Removal | Automated Acidification + Sparging (NPOC Mode) |
| Blank Water Generation | Onboard Deionized Water Purification System |
| Compliance | Designed to support ASTM D7573, ISO 8245, USP <643>, and EPA Method 415.3 workflows |