SIGNAL
Filter
Showing all 14 results
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | 3010Plus |
| Instrument Type | Portable |
| Compliance | HJ/T 38–2017, HJ 1012–2018, GB 17691–2018, GB 18352.6–2016, DB11/T 1367–2016, DB37/T 3922 |
| Brand | Signal |
|---|---|
| Origin | UK |
| Model | AURORA |
| Instrument Type | Online Gas Analyzer |
| Measurement Principle | Paramagnetic Detection |
| Oxygen Range Options | 0–5% O₂, 0–10% O₂, 0–25% O₂ |
| Response Time (T₉₀) | < 2.5 s |
| Resolution | 0.1% O₂ |
| Linearity | ±0.1% O₂ full scale |
| Display | Color TFT Touchscreen Interface |
| Connectivity | Ethernet (Dedicated IP Address), Remote Web-Based Configuration & Diagnostics |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP65 (Optional for Industrial Installation) |
| Compliance | CE Marked, RoHS Compliant, Designed for ISO 17025 and GLP/GMP Environments |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump2L / iPump4L / iPump6L |
| Flow Rate Range | 0.0006–2416 mL/min |
| Speed Range | 0.01–600 RPM |
| Accuracy | ±0.5% |
| Display | 128×32 Graphic LCD |
| Control Interface | Rotary Encoder + Membrane Keypad |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional) |
| Protection Rating | IP31 |
| Power Supply | AC 90–260 V, 50/60 Hz |
| Operating Environment | 0–40 °C, <80% RH non-condensing |
| Dimensions (L×W×H) | 291 × 208 × 180 mm (driver only) |
| Weight | 3.8 kg (iPump2L), 50 W max |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump2S-D |
| Flow Rate Range | 0.006–1970 mL/min |
| Speed Range | 0.1–200 rpm |
| Speed Resolution | 0.1 rpm (<100 rpm), 1 rpm (≥100 rpm) |
| Display | 3-digit LED for speed and timer |
| Direction Control | Bidirectional |
| Timing Function | 0.1 s–99 h |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional) |
| Protection Rating | IP31 |
| Power Supply | AC 90–260 V, 50/60 Hz |
| Power Consumption | <50 W |
| Operating Environment | 0–40 °C, ≤80% RH non-condensing |
| Dimensions (L×W×H) | 224 × 147 × 227 mm (excl. pump head) |
| Weight | 3.8 kg |
| Enclosure Material | 304 stainless steel |
| PCB | Conformal coated (triple protection against moisture, corrosion, and dust) |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Model | iPump4S / iPump6S |
| Flow Rate Range | 0.008–2416 mL/min |
| Speed Range | 0.1–200 RPM (iPump4S), 0.1–600 RPM (iPump6S) |
| Speed Resolution | 0.1 RPM (<100 RPM), 1 RPM (≥100 RPM) |
| Power Consumption | 50 W (iPump4S), 75 W (iPump6S) |
| Input Voltage | AC 90–260 V, 50/60 Hz |
| Operating Environment | 0–40 °C, <80% RH non-condensing |
| Dimensions (L×W×H) | 291 × 208 × 180 mm (excl. pump head) |
| Weight | 3.6 kg |
| IP Rating | IP31 |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 with Modbus RTU protocol (optional module) |
| Footswitch Support | Yes (optional) |
| Display | 3-digit LED, showing speed and timer |
| Direction Control | Bidirectional |
| Timer Range | 0.1 s – 99 h |
| Memory Function | Power-loss retention of operational state |
| Brand | Signal |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | iPump6S-G + YZ35B |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 0.46–12 L/min |
| Speed Range | 40–600 RPM |
| Resolution | 1 RPM |
| Power Consumption | <300 W |
| Input Voltage | AC 180–260 V, 50 Hz |
| Operating Environment | 0–40 °C, RH <80% non-condensing |
| Enclosure Rating | IP31 |
| Dimensions (L×W×H) | 370 × 235 × 240 mm (excluding pump head) |
| Weight | 11.5 kg |
| Housing Material | 304 Stainless Steel |
| PCB Protection | Triple-Conformal Coated |
| Control Modes | Speed, Flow, Timer |
| Direction | Reversible |
| Timer Range | 1 s – 99 h |
| External Control Options | 0–5 V, 0–10 V, 4–20 mA, 0–10 kHz (optical isolation) |
| Communication | RS485 Modbus RTU (optional module) |
| Footswitch Support | Optional |
| Full-Speed Fill/Empty Function | Yes |
| Power-Fail Memory | Yes |
| Display | 4-digit LED (speed or flow, toggleable) |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | 3000HM |
| Detection Principle | Heated Flame Ionization Detection (HFID) |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Measurement Range | 0–4 / 10 / 40 / 100 / 400 / 1,000 / 4,000 / 10,000 ppm (auto-ranging) |
| Resolution | ±1% of full scale or ±0.2 ppm (whichever is greater) |
| Accuracy | ±1% of full scale or ±0.2 ppm (whichever is greater) |
| Response Time | T90 < 1.5 s |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | 4000VM |
| Measurement Principle | Vacuum-heated chemiluminescence detection |
| Output Options | Simultaneous NO/NO₂/NOₓ or switchable NO/NOₓ |
| Range | 0–4 ppm to 0–10 % (auto-ranging) |
| NH₃ Cross-sensitivity | None |
| NO Conversion Source | Carbon-based catalytic converter |
| Zero Reference | Neon lamp (ambient air NO-free calibration) |
| Operating Mode | Vacuum-heated or ambient-temperature non-vacuum (optional) |
| Compliance Ready | ASTM D6522, ISO 7935, EN 14792, US EPA Method 7E |
| Brand | SIGNAL |
|---|---|
| Origin | UK |
| Model | PULSAR |
| Detection Principle | Dual-Heated FID with High-Temperature Catalytic Oxidation Module |
| Instrument Type | Online Gas Analyzer |
| Detection Range | CO, CO₂, CH₄, N₂O, SO₂ |
| Resolution | 0.001 % vol |
| Accuracy | ±0.01 % of reading |
| Response Time | 2 s |
| Brand | Signal |
|---|---|
| Origin | UK |
| Model | PULSAR-01 |
| Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Response Time | < 2 s |
| Gas Species | O₂, CO, CO₂, CH₄, NO, N₂O, SO₂, HCl |
| Repeatability | High (per ISO 12039 and EN 15267-3 certified performance) |
| Compliance | CE-marked, RoHS-compliant, designed for EPA Method 10/18 and EN 14181 QAL1/QAL2 environments |
| Software Interface | S4i Remote Monitoring & Diagnostics Platform |
| Calibration | Multi-range, user-selectable, auto-calibration with relay-controlled gas switching |
| Display | Optional integrated touchscreen with USB/SD data logging |
| Brand | Signal |
|---|---|
| Origin | United Kingdom |
| Model | QUASAR |
| Detection Principle | Heated Vacuum Chemiluminescence |
| Measurement Targets | NO, NO₂, NOₓ (and optionally NH₃) |
| Operating Modes | Continuous Real-Time Monitoring |
| Compliance Standards | EN 14792, US EPA Method 7E |
| Vacuum System | Dry High-Vacuum Pump (standard) or Ambient-Pressure Option |
| Reaction Chamber | Heated (100–150 °C), Moisture-Tolerant |
| Detection Sensitivity | Sub-ppm (≤0.1 ppm) for NOₓ |
| Output | Simultaneous NO, NO₂, and NOₓ concentrations |
| Data Logging | Optional Integrated Color Touchscreen with Internal Storage |
| Software Interface | Windows-based Remote Control & Configuration (VB API Support) |
| Alarm Types | 10 Configurable Fault/Threshold Alarms (e.g., flow deviation, heater failure, EHT drift, calibration timeout, thermocouple fault) |
| Optional Ranges | Trace (0–10 ppm) and High-Range (0–10,000 ppm or 0–10% vol) |
| Sample Compatibility | Wet, hot, corrosive flue gases without pre-conditioning |
| Regulatory Context | Designed for GLP-compliant environmental monitoring and CEMS integration |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | S4-PULSAR |
| Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Type | Online Fixed-Mount Analyzer |
| Response Time | Gas- and concentration-dependent (typically < 15 s for major components) |
| Repeatability | ±0.5 ppm or ±1% of full scale (whichever is greater) for CO, CO₂, NO, SO₂, N₂O, CH₄, HCl, O₂ |
| Linearity | Better than ±1% FS |
| Display | 5.7″ color TFT touchscreen |
| Data Storage | Integrated SD card logging (all channels, timestamped) |
| Connectivity | USB host/device port |
| Software | Free PC-based data acquisition and configuration suite included |
| Compliance | Designed for continuous emissions monitoring (CEM) and laboratory-grade trace gas analysis |
| Sample Compatibility | Dry or humidified gas streams |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOLAR |
| Detection Principle | Heated Flame Ionization Detector (HFID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Dual-Channel VOC & NMHC Analyzer |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–1,000 ppm, 0–10,000 ppm |
| Resolution | ±1% of reading |
| Accuracy | ±1% of reading |
| Brand | Signal |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solar-01 |
| Pricing | Upon Request |
| Detection Principle | Heated Flame Ionization Detector (HFID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Compound VOC Analyzer |
| Resolution | ±1% of reading |
| Response Time | <2 seconds |