| Model | 415 |
| Price | Upon Request |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | AquaVent |
| Type | Ventilated Pressure-Based Water Level Transducer |
| Accuracy | ±0.05% FS |
| Temperature Range | −20 °C to 80 °C |
| Temperature Accuracy | ±0.05 °C |
| Data Storage | 40,000 full-resolution readings (expandable to 120,000 linearly compressed records) |
| Battery Life | 8 years (at 1-min logging interval) |
| Clock Accuracy | ±1 minute/year |
| Measurement Interval | 1/8 second to 99 hours |
| Housing Dimensions | 22 mm × 178 mm |
| Pressure Units | m, cm, ft, psi, kPa, bar |
| Temperature Units | °C, °F |
| Communication Protocols | RS-232, RS-485, SDI-12 |
| Environmental Rating (Wellhead Interface) | IP64 |
| Operating Temperature (Cable & Electronics) | −20 °C to 80 °C |
| Venting Cable Length | Customizable up to 152 m (500 ft) |
| Sensor Material | Hastelloy pressure element, 316 stainless steel housing, POM (polyoxymethylene), FKM (fluoroelastomer), and polyamide components |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | Biofoul Screen |
| Application | Protective mesh guard for Solinst Levelogger Edge, Levelogger Junior Edge, and LTC Levelogger Junior series |
| Compatible Sensor Type | Submersible water level loggers with integrated conductivity and pressure sensing elements |
| Material | Corrosion-resistant stainless steel (316 SS) |
| Mesh Opening | 0.5 mm nominal aperture |
| Outer Diameter | 25.4 mm (1.0 in) |
| Length | 76 mm (3.0 in) |
| Weight | 42 g |
| Operating Temperature Range | –20 °C to +50 °C |
| IP Rating | IP68 (fully submersible to 100 m depth) |
| Brand | Solinst |
|---|---|
| Origin | United Kingdom |
| Model | CO2LOG |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 400–10,000 ppm |
| Repeatability | ±1% of reading |
| Resolution | 30 ppm |
| Temperature Range | −20 °C to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Atmospheric Pressure Range | 300–1100 hPa |
| Pressure Accuracy | ±1.0 hPa |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH @ 25 °C |
| IP Rating | IP54 |
| Dimensions | 80 mm × 140 mm × 160 mm |
| Weight | 900 g |
| Data Storage | Removable micro-SD card (Excel-formatted .csv files) |
| Sampling Intervals | 30 min or 60 min |
| Battery Life | >12 months (at 1-hr interval, typical field conditions) |
| Wireless Option | Optional integrated radio module (up to 3 km line-of-sight range) |
| Inlet Airflow | Integrated low-power micro-fan for active sample aspiration |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | DataGrabber 3001 |
| Type | Pressure-Based Water Level Data Interface |
| IP Rating | IP64 |
| Operating Temperature | -20 °C to +50 °C |
| Power Supply | 9 V Alkaline or Lithium Battery |
| Battery Life | Up to 60 Full Downloads |
| Dimensions | Ø45.7 mm × 99.3 mm |
| Weight | 180 g |
| Compatible Loggers | Levelogger Edge, Jr., LTC, and Gold Series |
| USB Flash Drive Support | Standard USB 2.0 (up to 512 MB) |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | Driptych |
| Type | Acoustic Drip Counter |
| Power | Lithium Thionyl Chloride 1/2 AA 3.6 V |
| Dimensions | 55 × 55 × 65 mm |
| Weight | 300 g |
| IP Rating | IP65 (short-term submersion to 0.3 m) |
| Sensitivity | Detects ≥0.15 mL water droplets falling from ≤200 mm height |
| Max Drip Rate | 5 drops/s |
| Recording Interval | Configurable from 1 s to 24 h |
| Events per Bucket | Up to 16,383 |
| Total Buckets | 32,767 |
| Battery Life | Up to 10 years in sleep mode |
| Data Output | USB 3-pin interface |
| LED Indicators | Three status LEDs (power, activity, error) |
| Environmental Shielding | Acoustic noise rejection for false-trigger suppression (e.g., ambient sound, sheet flow) |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | Levelogger 5 Junior |
| Sensor Type | Submersible Pressure Transducer |
| Measurement Principle | Absolute Pressure with Temperature Compensation |
| Full-Scale Accuracy | ±0.1% FS |
| Data Storage Capacity | 40,000 paired temperature & water level readings |
| Sampling Interval Range | 0.5 seconds to 99 hours (user-selectable, linear or event-triggered) |
| Battery Life | Up to 5 years (typical continuous logging at 15-min intervals) |
| Enclosure Material | 316 stainless steel |
| IP Rating | IP68 (submersible to rated depth) |
| Pressure Ranges | 5 m H₂O (≈50 kPa) and 10 m H₂O (≈100 kPa) |
| Communication Interface | SDI-12 compliant |
| Software Compatibility | Levelogger EDGE v5.x or later |
| Calibration | Factory-calibrated with lifetime traceable calibration certificate |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | LTC |
| Type | Pressure-Based Water Level Logger |
| Housing Material | Titanium-Ceramic Coated |
| Pressure Sensor Material | Hastelloy |
| Conductivity Sensor | Quad-Platinum Electrode |
| Diameter | 22 mm |
| Length | 190 mm |
| Weight | ~200 g |
| Sampling Interval | 2 s – 99 h |
| Memory Capacity | 27,000 Data Points |
| Battery Life | ~8 Years |
| Temperature Range | −20 to +80 °C |
| Temp Accuracy | ±0.05 °C (with temperature compensation) |
| Temp Resolution | 0.003 °C |
| Depth Ranges | 5, 10, 20, 30, 100, or 200 m H₂O |
| Depth Accuracy | ±0.05% FS |
| Depth Resolution | 0.2–0.6 cm (dependent on range) |
| Conductivity Range | 0–100,000 µS/cm |
| Calibration Range | 50–80,000 µS/cm |
| Conductivity Accuracy | ±1% (5,000–80,000 µS/cm) |
| Conductivity Resolution | ±0.1 µS/cm |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | Levelogger 5 |
| Type | Pressure-Based Water Level Logger |
| Pressure Sensor Material | Hastelloy® |
| Housing Coating | Titanium PVD |
| Temperature Compensation Range | -10 °C to +50 °C |
| Accuracy (Full Scale) | 0.05% FS |
| Resolution | 24-bit |
| Temperature Accuracy | ±0.05 °C |
| Temp. Resolution | 0.003 °C |
| Battery Life | 10 years @ 1-min interval |
| Memory Capacity | 150,000 readings |
| Communication | Optical IR, RS-232, USB, SDI-12 |
| Dimensions | Ø22 mm × 159 mm |
| Weight | 129 g |
| Operating Temperature | -20 °C to +80 °C |
| Enclosure Material | 316 stainless steel, Hastelloy®, titanium-coated, POM, FKM |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 101 |
| Category | Fiber-Optic Water Level Sensor |
| Accuracy | ±1 mm (±0.01 ft) |
| Probe Options | P2 Standard (surface use), P7 Submersible (up to 300 m) |
| Tape Material | UV-stabilized polyethylene with embedded stainless-steel conductors |
| Tape Width | 9.5 mm (3/8 in) |
| Max Tape Length | 1800 m (6000 ft) |
| Power | 9 V alkaline battery |
| Output Indication | Audible buzzer + LED flash |
| Sensitivity Adjustment | Continuously variable conductivity threshold |
| Scale Marking | Permanent heat-embossed dual-side markings (mm & 0.01 ft) |
| Reel Design | Ergonomic hand-crank reel with mechanical brake, on/off switch, battery test button, and integrated probe holder |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 101B |
| Sensor Type | Conductivity-based water level probe |
| Probe Dimensions | 12.7 mm diameter × 102 mm length |
| Probe Weight | 100 g |
| Tape Material | Polyethylene (PE) tape with heat-embossed metric graduations (cm and m) |
| Standard Tape Lengths | 30 m, 60 m, 100 m |
| Construction | Stainless steel probe, corrosion-resistant reel and ergonomic handle |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 102 |
| Type | Capacitive/Conductive Water Level Detection Tape |
| Cable Diameter | 10 mm |
| Graduation | Laser-etched permanent markings at 1 mm intervals |
| Probe Options | P10 (10 mm × 70 mm, 174 g) and P4 (4 mm × 38 mm, 10 g) |
| Power Source | 9 V battery |
| Output Indication | Visual LED + audible buzzer |
| Compliance | Designed for field-deployable groundwater monitoring per ASTM D4044, ISO 555–2, and USGS NWIS protocols |
| Brand | Solinst |
|---|---|
| Country of Origin | Canada |
| Model | 104 |
| Product Type | Ultrasonic Water Level Meter |
| Measurement Range | 3–600 m (9–2000 ft) |
| Accuracy | ±3 cm (±0.1 ft) |
| Resolution | 1 cm (0.05 ft) |
| Operating Temperature | −20 to +45 °C (−10 to +110 °F) |
| Power Supply | 6 × AA alkaline batteries |
| Battery Life | Up to 500 h (21 days in power-saving mode) |
| Display | Backlit LCD with keypad interface |
| Probe Cable Length | 1.8 m (6 ft) |
| Probe Dimensions | 16 × 8 × 7 cm (6 × 3 × 3 in) |
| Control Unit Dimensions | 19 × 9 × 4 cm (7.5 × 3.5 × 1.5 in) |
| Control Unit Weight | 390 g (14 oz) |
| Units | Metric or Imperial selectable |
| Response Time | ~1 s at 150 m |
| Temperature Compensation | Integrated NTC sensor |
| Compliance | Designed for field-deployable environmental monitoring per ASTM D4044, ISO 14001-aligned workflows, and GLP-compliant data capture |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 105 |
| Pricing | Upon Request |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 122 |
| Measurement Principle | Infrared Refractive Index Discrimination at Liquid-Liquid Interfaces |
| Depth Range | 20–450 m |
| Probe Diameter | 16 mm (5/8") |
| Probe Material | Stainless Steel |
| Maximum Pressure Rating | 500 psi |
| Accuracy | ±1 mm (±1/200 ft) |
| Power Source | Replaceable Batteries |
| Battery Life | ≥120 h |
| Auto-Shutoff | After 10 minutes of inactivity |
| Probe Tip Material | Hydex™ polymer with integrated stainless steel guard |
| Scale Options | LM2 (1/100 ft, black markings) or LM3 (mm/m, black markings) |
| Compliance | CSA Certified for hazardous locations |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 408 |
| Instrument Type | Portable Pneumatic Groundwater Sampler |
| Sampling Depth | 150 m |
| Sampling Flow Rate | ≤100 mL/min |
| Valve Actuation | Compressed Air-Driven Dual-Valve Mechanism |
| Construction Materials | 316 Stainless Steel (42 mm or 16 mm OD) or PVC |
| Manual Winch Compatibility | Yes, with Brake Disc for Depth Locking |
| Electrical Control Option | Compatible with Solinst Model 464 Electronic Controller |
| Sample Volume Control | Discrete, Operator-Initiated |
| Compliance | Designed for ASTM D5088, ISO 5667-3, and EPA Method 502.2 field-sampling protocols |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 410 |
| Pump Type | Peristaltic |
| Flow Rate Range | 40–3200 mL/min |
| Speed Control | Variable, Reversible DC Motor |
| Power Supply | 12 V DC (3–5 A recommended) |
| Dimensions | 33 × 12 × 17 cm (13 × 5 × 6.5 in) |
| Weight | 3.6 kg (8 lb) |
| Tubing Compatibility | Standard 16 mm OD medical-grade silicone tubing |
| Max Suction Lift | ~10 m (33 ft) at sea level |
| IP Rating | IP67-equivalent enclosure (fully sealed, no open grilles or vents) |
| Safety Features | Reverse-polarity protection, replaceable fuse |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 425 |
| Sampling Depth | 150 m |
| Sample Volume per Cycle | 1800 mL |
| Volume Accuracy | ±1% |
| Fill Rate | 1800 mL/min |
| Minimum Sampling Interval | 5 min |
| Sampler Type | Manual, Portable, Discrete-Depth |
| Sampling Method | Pressure-actuated, Hydrostatic-fill |
| Construction Materials | Stainless Steel Body, Viton O-rings, PTFE Components, LDPE Tubing (standard), Optional FEP-lined PE Tubing |
| Compliance | ASTM D6771, ASTM D7929, ISO 5667-3, US EPA Method 502.2, US EPA Method 8260D (VOCs), GLP-Compatible Operation |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 428 |
| Instrument Type | Portable Manual Water Bailer Sampler |
| Sample Volume | 200–1000 mL |
| Construction Material | HDPE (High-Density Polyethylene) |
| Body Transparency | Semi-transparent |
| Check Valve | Fixed PVC ball valve |
| Dimensions (Standard) | 38 mm Ø × 915 mm L (1.5″ × 36″), total length 965 mm (38″) |
| Narrow Version Dimensions | 19 mm Ø × 1016 mm L (3/4″ × 40″), total length 1041 mm (41″) |
| Release Mechanism | Standard or optional low-flow release assembly |
| Compliance | Designed for ASTM D6771, ASTM D6987, and EPA Method 500.0 field sampling protocols |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Model | 429 |
| Instrument Type | Portable Manual Water Sampler |
| Sampling Method | Discrete Depth Bailer |
| Single Sample Volume | 50–2000 mL |
| Sampling Depth | Unlimited (Depth-Limited Only by Cable Length & Well Geometry) |
| Construction Material | 316 Stainless Steel with PTFE Ball Valves and Viton O-Rings |
| Standard Lengths | 2 ft (610 mm), 3 ft (910 mm), 4 ft (1220 mm) |
| Diameter Options | 0.5 in (12.7 mm), 1.0 in (25.4 mm), 1.5 in (38.1 mm), 2.0 in (50.8 mm) |
| Sample Release Mechanism | Integrated Stainless Steel Controlled-Flow Dispenser |
| Recommended Support Line | Solinst Model 103 Marked Measuring Line |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 703 |
| Price | USD 1 (Reference Only) |