Thermo Fisher
Filter
Showing 1–30 of 376 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Diode Array Detector (DAD) |
| Model | ICS-PDA |
| Wavelength Range | 190–800 nm |
| Detector Array | 1024-element photodiode array |
| Light Sources | Deuterium and tungsten lamps |
| Interface | USB + 4 analog outputs |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation in Chromeleon™ CDS |
| Baseline Drift | Low, enabling high reproducibility in quantitative UV-Vis chromatographic analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher Scientific brand) |
| Type | Portable Multi-parameter Electrochemical Analyzer |
| Model | pH450 |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Points | Up to 5 (USA/NIST), up to 6 (DIN), or up to 5 user-defined points |
| Buffer Recognition | Automatic (USA/NIST/DIN) |
| Calibration Expiry Alert | Configurable |
| Data Storage | 500 datasets with timestamp (RTC) |
| Connectivity | USB and RS232 |
| Power | 2 × AA batteries (typical life >2000 hours) or optional AC adapter |
| Enclosure Rating | IP67 |
| Electrode Interface | BNC |
| Temperature Unit | °C/°F selectable |
| GLP Compliance | Yes (time-stamped calibration & measurement records) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | RadEye GR |
| Instrument Type | Portable Dose Rate Meter |
| Detector Type | Sodium Iodide (NaI) Scintillator |
| Wireless Range | 100 m |
| Detector Battery Life | 1300 h |
| Display Unit (RadEye R) Battery Life | 600 h |
| Operating Temperature | –25 °C to +50 °C |
| Compliance | Meets ANSI N42.33, IEC 60846-1:2014, and EU Directive 2013/59/Euratom for portable radiation monitoring devices |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 1R 120354-A110 |
| Category | Mass Spectrometry Component |
| Import Status | Genuine Imported OEM Part |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Fisher 8000 Series Online Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | AAA-Direct |
| Pricing | Upon Request |
| Pump Material | PEEK (chemically inert, pH 0–14 compatible) |
| Pump Type | Tandem dual-piston, constant stroke |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | <0.1% at 1.0 mL/min |
| Flow Precision | <0.1% RSD at 1.0 mL/min |
| Pressure Range | 50–5000 psi |
| Pressure Pulsation | ≤1% |
| Gradient Ratio Accuracy | ±0.5% at 2.0 mL/min |
| Gradient Ratio Precision | ±0.5% RSD at 2.0 mL/min |
| Eluent Options | Isocratic: 1 |
| Gradient | up to 4 |
| Gradient Delay Volume | <400 µL |
| EG Concentration Range | 0.01–100 mM |
| EG Compatible Eluents | KOH, LiOH, NaOH, CO₃²⁻/HCO₃⁻, CO₃²⁻, MSA |
| EG Concentration Increment | 0.01 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| Max EG Operating Pressure | 3000 psi (21 MPa) |
| Organic Solvent Tolerance | Anion mode: ≤25% methanol |
| Cation mode | solvent-free aqueous only |
| Operating Temperature | 4–40 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Dimensions (H×W×D) | 41×23×56 cm |
| Weight | 25 kg |
| Power | 90–265 V AC, 47–63 Hz |
| Ion Reservoir Dimensions | 23×7×10 cm, 1.6 kg |
| Cr-TC Trap Column | 3.8×3.8×5.8 cm, 60 g |
| Eluent Organizer (EO) | Holds four 1–2 L or two 4 L chemically resistant PE/epoxy-coated bottles |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | ABBE-3L |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AI/AS 1310 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity | 8-position (AI 1310) or 155-position (AS 1310) |
| Needle Wash Options | Single or dual-solvent (A/B/C/D, A+B, C+D) pre- and post-injection |
| Injection Modes | Minimum Needle Depth & Standard Needle Depth |
| Compatibility | Thermo Scientific GC systems (e.g., TRACE 1300/1600 series) |
| Upgrade Path | AI 1310 → AS 1310 |
| Optional Dual-Inlet Kit | AS 1310 Gemini Kit (enables simultaneous dual-port injection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3500 Dx / 3500xL Dx |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Throughput | 1104 samples/day |
| Read Length Range | 30–1000 bp |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 1000 reads per 120 min |
| Data Format | Capillary Electrophoresis-Based Sequencing |
| Software | Data Collection Software v3, Sequencing Analysis v6, KB Basecaller v1.4.1, Variant Reporter™, SeqScape®, GeneMapper®, GeneMapper ID-x®, MicroSEQ ID® |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Aquakem 600 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Principle | Discrete Photometric Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem200 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | Up to 180 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Maximum Reagents per Test | 4 |
| Wavelength Range | 340–880 nm |
| Barcode Reader | Integrated |
| Sample Dilution | Auto pre-dilution and auto re-dilution |
| Cadmium Reduction Module | Optional (for nitrate analysis) |
| System Architecture | Open-platform, user-definable methods, reagents, and protocols |
| Probe Function | Dual-purpose pipetting probe with integrated mixing capability |
| Wash System | Automatic internal/external probe washing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem250 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | 250 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Maximum Reagents per Test | 4 |
| Cadmium Reduction Module | Optional |
| Barcode Reader | Integrated |
| Sample/Reagent Dispensing | Fully Automated with Internal/External Tip Washing |
| Dilution Capability | Auto Primary & Secondary Dilution |
| Stirring | Independent Stir Bars with Dedicated Wash Station |
| Reagent Flexibility | User-Defined Methods and Custom Reagent Preparation Supported |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Aquanex Ultra-Pure Water System |
| Pricing | Upon Request |
| Water Purity Grade | ASTM Type I (Ultra-Pure Water) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Arena 20XT |
| Instrument Category | Beverage & Food-Specific Analyzer |
| Detection Throughput | Up to 250 tests/hour |
| Sample Capacity | 84 positions |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Incubation Slots / Tests per Run | 6 slots / 72 tests |
| Sample Cup Format | Disposable 12-well multi-cuvette strips (up to 50 strips = 600 tests) |
| Onboard Barcode Reader | Yes |
| Reagent Management | Ready-to-use kits with real-time reagent level monitoring |
| Liquid Handling | Fully automated sample/reagent dispensing with dual-wall washing |
| Dilution Capability | Integrated automatic pre-dilution and secondary dilution |
| Water Consumption | <1.0 L/h (internal reservoir-fed, no plumbing required) |
| Incubation Temperature Control | Adjustable |
| Stirring | Independent stirrer rods with dedicated wash station |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Arena20 |
| Instrument Category | Beverage & Food-Specific Analyzer |
| Optical Range | 275–700 nm |
| Reaction Volume | Microliter-scale (sample + reagent) |
| Detection Methodology | Photometric (absorbance), Enzymatic Assay, and Bitterness Unit (BU) Quantification |
| Sample Throughput | Random-access, on-demand analysis with variable throughput configurations |
| System Architecture | Open-platform, user-programmable method environment |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Arena30 |
| Instrument Type | Beverage & Food Biochemical Analyzer |
| Throughput | Up to 300 tests/hour |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 84 positions (including 20 calibrator + 19 control positions) |
| Reagent Capacity | 45 refrigerated positions |
| Cuvette Format | Disposable 12-well multi-cuvette strips (up to 50 strips = 600 tests) |
| Incubation Stations | 6 positions / 72 total incubation slots |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Barcode Reader | Integrated |
| Water Consumption | <1.5 L/h (internal reservoir-fed, no plumbing required) |
| Software | Open-method platform with customizable protocols, reagents, and assay parameters |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Arena60 |
| Instrument Type | Beverage & Food Biochemical Analyzer |
| Throughput | Up to 600 tests/hour |
| Wavelength Range | 340–880 nm |
| Sample Positions | 84 (including 20 calibrator + 19 control positions) |
| Refrigerated Reagent Positions | 45 |
| Incubation Capacity | 20 cuvettes per cycle, 240 tests per incubation batch |
| Multiwell Cuvette Capacity | 175 strips (2100 total tests) |
| Onboard Operation Time | Up to 4 hours |
| Dilution Capability | Integrated primary and secondary auto-dilution |
| Water Consumption | <2.0 L/h |
| Barcode Reader | Built-in |
| Reagent Management | Real-time reagent volume monitoring |
| Cuvette Type | Disposable multi-cuvette strips (low-volume, cross-contamination-free) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | easySpark 1160 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ARL Perform’X |
| Instrument Type | Floor-standing |
| Instrument Class | Scanning-type |
| X-ray Tube Power Options | 1500 W / 2500 W / 4200 W |
| Elemental Range | Be to U (Atomic Number 4 to 92) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ARL QUANT'X |
| Form Factor | Benchtop/Floor-standing |
| Application Scope | General-purpose |
| Elemental Range | F to U (no elemental restrictions) |
| Quantification Range | <1 ppm to 100% |
| Energy Resolution | ≤140 eV at Mn Kα |
| Short-term Precision | RSD < 0.3% over 8 hours |
| Detector | High-performance Peltier-cooled Silicon Drift Detector (SDD) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ/θ |
| Angular Accuracy | ±0.002° |
| Detector | Solid-state 2D pixel detector (55 × 55 µm pixel pitch) |
| Sample Handling | Manual 1-position holder or optional 6-position autosampler |
| X-ray Source | Cu or Co sealed-tube anode |
| Cooling | Optional water-cooling system |
| Data Output | Automated LIMS integration |
| Compliance | IEC 61000-4, IEC 62471, EN 61000-6-3, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | AutoTrace 280 |
| Automation Level | Fully Automated |
| Channel Count | 6-Channel |
| Extraction Format | Cartridge-Based SPE (with optional 47 mm disk support) |
| Solvent Selection | 5 Solvents (automated selection for conditioning, washing, elution) |
| Sample Volume Range | 20 mL – 20 L |
| Compatible SPE Formats | 1 mL, 3 mL, 6 mL cartridges and 47 mm SPE disks |
| Dual-Cartridge Mode | Supported |
| Waste Management | Separate aqueous/organic waste lines |
| Valve Material | PEEK rotary 12-port valve (acid/base compatible) |
| Software | AutoTrace 280 Control Software (24 user methods onboard |
| Regulatory Alignment | EPA-compliant for water analysis (e.g., EPA Methods 508.1, 525.3, 549.2, 625.1) |
| Power | 100–240 VAC, 47–63 Hz, ≤150 VA |
| Dimensions (H×W×D) | 57 × 63.5 × 69 cm |
| Weight | 68.1 kg |
| Air Pressure | 0–30 psi (0–1.4 bar) output |
| Pump Accuracy | ±2.5% |
| Fluid Path Materials | Stainless steel tubing, TFE, Kynar®, ceramic pistons, Rulon® valve seals |
| Exclusion | Acetic acid and acetone not recommended |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biomate 160 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Chromeleon® 7 |
| Software Type | Chromatography & Mass Spectrometry Data System |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP, GMP |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Thermo Fisher Cindion Combustion Ion Chromatography System |
| Price | Upon Request |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Flow Rate Range | 100–500 mL/min |
| Maximum Operating Pressure | 30–45 psi |
| Operating Temperature Range | 500–1200 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DFS High-Resolution GC/MS |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| GC Configuration | Dual-Column, Dual-Trace 1310 GC Integration |
| Automation | TriPlus RSH Autosampler |
| Ion Source | Removable, Vacuum-Lock Ion Box |
| Analyzer Architecture | Double-Focusing Magnetic Sector with Ring-shaped Electrostatic Analyzer (ESA) |
| Calibration | Field-Based Mass Calibration Independent of Scan Speed, Ion Polarity, and Ionization Mode |
| Detection | Dual-Stage Electron Multiplier with Pneumatic Valve Vacuum Lock |
| Regulatory Compliance | Designed for EPA Method 1613/8270, EU Directive 2006/122/EC, WHO IPCS Dioxin Guidelines, USP <1225>, FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Thermo Fisher |
|---|---|
| Model | DFS |
| Type | Double-Focusing Magnetic Sector GC-MS |
| Detector | Dual-Channel Electron Multiplier with Convertor Electrode |
| Resolution | Up to 100,000 (10% Valley) |
| Mass Range | 10–2000 m/z |
| Ion Source | Removable, Modular EI/CI Source |
| Vacuum System | Pneumatic Valve Lock for Ion Box Exchange Without Venting |
| GC Compatibility | Dual Trace 1310 GCs on Single Ion Source |
| Automation | TriPlus RSH Autosampler with Dual-Column Sequential Injection |
| Calibration | Field-Based, Mode-Independent Mass Calibration |
| Software | Thermo Xcalibur with DFS-Specific Acquisition & Quantitation Modules |
| Compliance | Designed for EPA Method 1613/8270, EU 2017/625, ISO 18073, and GLP/GMP environments requiring 21 CFR Part 11 audit trails |