TQC
Filter
Showing all 14 results
| Brand | TQC |
|---|---|
| Country of Origin | Netherlands |
| Model Range | AB3120–AB3405 |
| Power Supply | 115–230 V, 50–60 Hz |
| Bed Type | Flat Glass Bed (AB3120/AB3125) |
| Speed Range | 2–500 mm/s |
| Stroke Length | 50–359 mm |
| Stroke Accuracy | ±2 mm |
| Speed Accuracy | ±1% of set value |
| Substrate Size | DIN A3 (297 × 420 mm) |
| Maximum Coater Length | 300 mm |
| Maximum Coater Height | 80 mm |
| Wire Rod Length | Up to 325 mm (spiral zone: 364 mm) |
| Wire Rod Max Diameter at Mounting Point | Ø10 mm |
| Vacuum Capacity | –178 mbar (models with vacuum pump) |
| Dimensions (L×W×H) | 650 × 350 × 240 mm |
| Display | Monochrome LCD (193 × 64 px, 100 × 35 mm active area) |
| Power Consumption | ≤80 W (base unit) |
| Safety Compliance | EU Machinery Directive 2006/42/EC |
| Operating Temperature Range (Heated Models) | Ambient +5 °C to Ambient +100 °C (absolute max 140 °C) |
| Temperature Resolution | 1 °C (set), 0.1 °C (readout) |
| Dry Time Recorder | 1 min–2880 min (48 h), accuracy <1% of set time, up to 8 concurrent measurements |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | CURVE-X2 |
| Temperature Range | –50 °C to 1200 °C |
| Accuracy | ±0.3 °C |
| Resolution | 0.1 °C |
| Thermocouple Type | NiCr–Ni (Type K) |
| Probe Inputs | 6–12 channels |
| Operating Temperature | 0–60 °C |
| Sampling Interval | 1 second to 1 hour |
| Memory Capacity | 254,000 data points (10 user-definable groups, 25,000 points per group) |
| Power Supply | 3 × AA 1.5 V alkaline batteries (up to 1200 hours continuous logging) |
| Dimensions (Logger) | 30 × 105 × 85 mm (H × L × W) |
| Weight (Logger) | 285 g |
| Insulation Box Dimensions | 66 × 192 × 145 mm (H × L × W) |
| Insulation Box Weight | 1600 g |
| Predefined Coating Profiles | 15 |
| Curve-Index Calculation | Built-in |
| Display | Backlit graphical LCD |
| Auto-Start/Stop Triggers | Time/date-based or temperature-threshold-based |
| Software | Ideal Finish™ (included) |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | DV1300 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 40.2 – 141 KU |
| Speed | 200 rpm |
| Resolution | 0.1 KU |
| Weight | 8.5 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Operating Temperature | +10 °C to +40 °C |
| Protection Rating | IP20 |
| Interface | Unidirectional RS232 |
| Display | 4-line backlit LCD |
| Compliance | ASTM D562, ASTM D1131, ASTM D856 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | DV1400 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 40.2 – 141 KU (Krebs Units) |
| Operating Speeds | 20 rpm and 60 rpm (fixed) |
| Power Supply | Rechargeable battery |
| Weight | 1.8 kg |
| Display | Dual-line backlit LCD |
| Compliance | ASTM D562, ISO 2555, BS 3900-A6, EN ISO 2555 |
| Includes | Rotor set and standard sample cup |
| Brand | TQC |
|---|---|
| Country of Origin | Netherlands |
| Model | GL0010 (60°), GL0020 (20°/60°), GL0030 (20°/60°/85°) |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0–2000 GU |
| Repeatability | ≤0.2 GU (60° & 85°), ≤0.4 GU (20°) |
| Reproducibility | 1.58–1.88 GU |
| Resolution | 0.1 GU (0–100 GU), 1 GU (>100 GU) |
| Light Source | Stable LED |
| Display | High-contrast OLED |
| Dimensions | 90 × 140 × 45 mm |
| Weight | 398 g |
| Power | 2 × AA batteries |
| Interface | USB |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, ASTM C584, BS 3900 D5, DIN 67530, JIS Z 8741, AS 1580 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sheen Efflux Cup |
| Pricing | Upon Request |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | SP0500 (Host Unit), SP0505 (Konig Pendulum), SP0510 (Persoz Pendulum) |
| Compliance | ISO 1522:2005, NBN T22-105, BS 3900-E5 |
| Power Supply | 230 V / 115 V AC |
| Dimensions (Closed) | 740 × 430 × 430 mm |
| Dimensions (Open) | 960 × 430 × 650 mm |
| Weight | 26 kg |
| Pendulum Support | Tungsten Carbide Pivot Balls (Ø8 mm for Konig, Ø5 mm for Persoz) |
| Konig Oscillation Period | 1.0 s |
| Persoz Oscillation Period | 1.4 s |
| Damping Time on Standard Glass | ≥430 ±15 s (Konig), 250 ±10 s (Persoz) |
| Sample Max Size | 105 × 200 × 11 mm (Konig), 105 × 200 × 8.3 mm (Persoz) |
| Glass Plate Thickness | 6 mm |
| Enclosure Material | PERSPEX® Acrylic |
| Housing Material | Powder-Coated Steel, Stainless Steel Front Panel, Anodized Aluminum Side Panel |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | SP1820 |
| Compliance | ISO 1519 |
| Mandrel Diameters | 2, 3, 4, 5, 6, 8, 10, 12, 13, 16, 19, 20, 25, 32 mm |
| Test Panel Max Size | 150 × 100 mm |
| Certification | QUALICOAT, QIB, GSB accredited |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | SP1830 |
| Mandrel Diameter Range | 3.1–38 mm |
| Test Panel Dimensions | 100 × 180 mm |
| Maximum Panel Thickness | 0.8 mm |
| Construction | Anodized Aluminum Alloy Base & Stainless Steel Mandrel Assembly |
| Compliance | ISO 6860, ASTM D522 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | SP1880 / SP1895 / SP1890 / SP1891 |
| Testing Principle | Falling-weight impact (direct & indirect) |
| Compliant Standards | ISO 6272-1, ISO 6272-2, ASTM D2794, ASTM G14 |
| Impact Type | Direct impact (SP1890, SP1891, SP1895) and indirect impact (SP1880) |
| Indenter Options | 12.7 mm & 15.9 mm cylindrical punches |
| Weight Options | 0.9 kg, 1.0 kg, 1.361 kg (2.2 lb) |
| Die Diameter Options | 16.3 mm, 27 mm |
| Sample Holder | V-groove fixture (SP1895), flat die support (SP1880/SP1890/SP1891) |
| Calibration Certificate | Supplied with traceable calibration documentation per ISO/IEC 17025-accredited lab |
| Regulatory Alignment | Designed for GLP-compliant coating QC workflows |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | SP4300 |
| Instrument Type | Automatic |
| Drive Mechanism | Electronic micro-stepping motor |
| Stroke Range | 0–12 mm |
| Stroke Resolution | 0.01 mm |
| Punch Speed Range | 0.01–0.70 mm/s |
| Speed Accuracy | ±1% of set value |
| Stroke Accuracy | ±0.01 mm |
| Max. Test Panel Width | 100 mm |
| Max. Steel Thickness | 0.8 mm |
| Max. Aluminum Thickness | 1.2 mm |
| Dimensions (D×W×H) | 450 × 350 × 600 mm |
| Net Weight | ~31 kg |
| Power Supply | 115–230 V, 50–60 Hz |
| Max. Power Consumption | 80 W |
| Display | Backlit LCD with multilingual UI |
| Safety Features | Emergency stop button, audible alarm |
| Compliance | ISO 1520, DIN EN ISO 1520, DIN 53156, DIN 53232, BS 3900-E4, NBN T22-104, NF T30-019 |
| Certification | Qualicoat & QIB Laboratory Accredited |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | VF0600 / VF1200 |
| Light Sources | D65 (6500 K), TL84 (4000 K), D50 (5000 K), F/A (2700 K), A (2856 K), INCA, UV |
| Internal Finish | Munsell N5.5 Gray |
| Viewing Angle | 45° |
| Dimensions (Booth) | 680 × 360 × 380 mm (VF0600) / 1280 × 590 × 590 mm (VF1200) |
| Viewing Table | 400 × 270 mm, Munsell N5.5 Gray, MDF Construction |
| Warm-up Time | 4–6 h |
| D65 Lamp Lifetime | 2000 h |
| Compliance | ASTM D1729, ISO 3664 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | VF2020 |
| Material | Anodized Aluminum Body with Stainless Steel Orifice Holder |
| Orifice Diameter Options | 1–7 mm (VF2181–VF2027), 4 mm Orifice Complies Fully with DIN 53211 |
| Capacity | 100 mL |
| Weight | 226 g |
| Max Width | 84 mm |
| Height | 74 mm |
| Compliance | DIN 53211 (4 mm orifice), ASTM D1200 (approximate equivalence), ISO 2431 (methodological alignment) |
| Calibration Recommendation | Annual traceable calibration recommended |
| Accessories Available | Leveling stands (VF2061, VF2062), temperature controllers (VF1982, VF2067), certified stopwatch (DI0076), viscosity conversion chart (VF2053) |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 20 – 40,000,000 mPa·s |
| Speed Range (V2) | 0.1 – 200 rpm |
| Rotor Sets | L-type (4), R-type (6), H-type (6) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Compliance | ASTM D1076, D115, D1439, D1638, D1824 |